Zheng Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zheng Yuan has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Libo Zhao
School of Instrument Science and Technology, Xi’an Jiaotong University, Xi’an, China
5 shared publications - Zhikang Li
School of Instrument Science and Technology Xi'an Jiaotong University Xi'an China
4 shared publications - Jiawei Yuan
State Key Laboratory for Manufacturing System Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi’an Jiaotong University, Xi’an 710049, China
3 shared publications - Jie Li
School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
3 shared publications - Shaohui Qin
State Key Laboratory for Manufacturing Systems Engineering, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Research Institute for Intelligent Sensing Technology and System (Yantai), School of Instrument Science and Technology, School of Mechanical Engineering, Xian Jiaotong University, Xian, China
3 shared publications - Song Feng
School of Advanced Manufacturing Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China
3 shared publications
Latest Publications
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (13) , 23842-23856
Design and Modeling of CMUTs With T-Shape Cavities for Low Working Voltage, High Ultrasound Transmission and Reception
Low-voltage, high-performance capacitive micromachined ultrasonic transducers (CMUTs) are in urgent demand for portable ultrasound imaging and human-machine interfaces. However, most existing CMUTs exhibit superior comprehensive performance due to conflicting requirements in their structural design, which constrains their practical applications. This paper proposes a novel CMUT with T-shape cavities to achieve synergistic enhancement of multiple key performances by harnessing the electrostatic stiffness softening effect (ESSE). The unique T-shape cavity design features a smaller electrode distance in the peripheral area compared to the central area, which produces a higher electric field intensity and thus a larger membrane stiffness drop in the peripheral area of the vibrating membrane through the corresponding enhancement of ESSE. This special stiffness adjustment strategy ultimately enables the entire membrane to produce piston-like deformation, significantly improving both the maximum and average membrane deformation, and contributing to enhancements in operation voltage, transmitting and receiving sensitivities, electromechanical coupling coefficient, etc. The finite element method (FEM) is employed to investigate the device’s performance. Compared to conventional CMUTs, T-CMUTs reduce collapse voltage by 36.2%, with transmitting/receiving sensitivities and electromechanical coupling coefficient improved by 56.1%, 62.6%, and 76.0% under the same bias ratios; furthermore, these parameters improve by 371.0%, 516.0%, and 618.4% respectively at same bias voltages. An analysis of the stress distribution of the membrane further verifies the underlying mechanism of the T-shape cavity in enhancing device performance. Additionally, the foreseeable simple process and feasibility in consistent fabrication endow the proposed CMUTs with significant potential for practical application.
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (13) , 23842-23856
Design and Modeling of CMUTs With T-Shape Cavities for Low Working Voltage, High Ultrasound Transmission and Reception
Low-voltage, high-performance capacitive micromachined ultrasonic transducers (CMUTs) are in urgent demand for portable ultrasound imaging and human-machine interfaces. However, most existing CMUTs exhibit superior comprehensive performance due to conflicting requirements in their structural design, which constrains their practical applications. This paper proposes a novel CMUT with T-shape cavities to achieve synergistic enhancement of multiple key performances by harnessing the electrostatic stiffness softening effect (ESSE). The unique T-shape cavity design features a smaller electrode distance in the peripheral area compared to the central area, which produces a higher electric field intensity and thus a larger membrane stiffness drop in the peripheral area of the vibrating membrane through the corresponding enhancement of ESSE. This special stiffness adjustment strategy ultimately enables the entire membrane to produce piston-like deformation, significantly improving both the maximum and average membrane deformation, and contributing to enhancements in operation voltage, transmitting and receiving sensitivities, electromechanical coupling coefficient, etc. The finite element method (FEM) is employed to investigate the device’s performance. Compared to conventional CMUTs, T-CMUTs reduce collapse voltage by 36.2%, with transmitting/receiving sensitivities and electromechanical coupling coefficient improved by 56.1%, 62.6%, and 76.0% under the same bias ratios; furthermore, these parameters improve by 371.0%, 516.0%, and 618.4% respectively at same bias voltages. An analysis of the stress distribution of the membrane further verifies the underlying mechanism of the T-shape cavity in enhancing device performance. Additionally, the foreseeable simple process and feasibility in consistent fabrication endow the proposed CMUTs with significant potential for practical application.
- 29 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (1) , 727-738
An Inductive Sensor With a Biased Magnetic Field to Distinguish Wear Debris by Magnetism and Conductivity
Inductive wear debris sensors are an indispensable tool for real-time wear monitoring. Traditionally, these sensors contain only one type of magnetic field, time harmonic or static, and so cannot avoid the contradiction between magnetization and eddy current, resulting in limited performance. In this article, a detection method based on the biased magnetic fields is proposed for the first time, which can surpass this limitation in the traditional sensors. By coupling high-gradient biased static and high-frequency time-harmonic fields, the proposed sensor has the capability to enhance the precision of detecting both magnetic and nonmagnetic conductive particles simultaneously. In the following, the corresponding detection principle and mathematical model are presented, and relevant simulations are provided. Theoretical and simulation analysis illustrates the principle behind and the advantage of our work. Moreover, a signal processing system is developed to support the sensor testing. Experiments with different particle sizes and materials are carried out. The proposed sensor can identify a 50 μm copper particle and a 50 μm iron particle within a 4 mm diameter pipe, and the induction signal is linear with the volume of wear debris. The proposed method offers a new idea for inductive wear debris sensing, with great potential for higher accuracy and wider application scenarios.
- 29 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (1) , 727-738
An Inductive Sensor With a Biased Magnetic Field to Distinguish Wear Debris by Magnetism and Conductivity
Inductive wear debris sensors are an indispensable tool for real-time wear monitoring. Traditionally, these sensors contain only one type of magnetic field, time harmonic or static, and so cannot avoid the contradiction between magnetization and eddy current, resulting in limited performance. In this article, a detection method based on the biased magnetic fields is proposed for the first time, which can surpass this limitation in the traditional sensors. By coupling high-gradient biased static and high-frequency time-harmonic fields, the proposed sensor has the capability to enhance the precision of detecting both magnetic and nonmagnetic conductive particles simultaneously. In the following, the corresponding detection principle and mathematical model are presented, and relevant simulations are provided. Theoretical and simulation analysis illustrates the principle behind and the advantage of our work. Moreover, a signal processing system is developed to support the sensor testing. Experiments with different particle sizes and materials are carried out. The proposed sensor can identify a 50 μm copper particle and a 50 μm iron particle within a 4 mm diameter pipe, and the induction signal is linear with the volume of wear debris. The proposed method offers a new idea for inductive wear debris sensing, with great potential for higher accuracy and wider application scenarios.
- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-16
Noninvasive Stress Detection Based on Piezoelectric Micromachined Ultrasonic Transducers for Bolt Loosening Warning
Axial stress monitoring of bolts is significant to various engineering structures and machines because it can assist their reliable and durable operation, and prevent major failures and safety accidents. Among various sensing technologies, ultrasound holds prominent advantages in accuracy, noninvasiveness, non-destructive testing, etc. However, current ultrasonic technique predominantly relies on conventional bulk-PZT ultrasonic transducers, which suffer large size, high-power consumption, and inferior integration with ICs, hindering real-time and long-term monitoring and application in small bolts. This paper highlights the prospect of piezoelectric micromachined ultrasonic transducers (PMUT) in aforementioned application situations based on acoustic elastic effects and bolt length variations induced time differences. The corresponding theories for the relationship between the time difference and the stress are validated by finite element methods. A specific PMUTs with inner circular and outer annular arrays and optimized ultrasound frequencies were proposed to improve sensing performance. As such, the axial stress variation in a steel bolt with a nominal diameter as small as 6 mm is successfully monitored using our fabricated PMUTs chip with a resonant frequency of 850 kHz. Excellent linearity (≥0.998) between the ToF difference and applied stress and a high accuracy of less than 3% are demonstrated. Further, experimental testing of bolt stress under different practical conditions, such as bolt sizes, materials, and connection types validates the performance robustness and widespread applicability of our proposed PMUT-based ultrasonic stress sensing technique.
- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-16
Noninvasive Stress Detection Based on Piezoelectric Micromachined Ultrasonic Transducers for Bolt Loosening Warning
Axial stress monitoring of bolts is significant to various engineering structures and machines because it can assist their reliable and durable operation, and prevent major failures and safety accidents. Among various sensing technologies, ultrasound holds prominent advantages in accuracy, noninvasiveness, non-destructive testing, etc. However, current ultrasonic technique predominantly relies on conventional bulk-PZT ultrasonic transducers, which suffer large size, high-power consumption, and inferior integration with ICs, hindering real-time and long-term monitoring and application in small bolts. This paper highlights the prospect of piezoelectric micromachined ultrasonic transducers (PMUT) in aforementioned application situations based on acoustic elastic effects and bolt length variations induced time differences. The corresponding theories for the relationship between the time difference and the stress are validated by finite element methods. A specific PMUTs with inner circular and outer annular arrays and optimized ultrasound frequencies were proposed to improve sensing performance. As such, the axial stress variation in a steel bolt with a nominal diameter as small as 6 mm is successfully monitored using our fabricated PMUTs chip with a resonant frequency of 850 kHz. Excellent linearity (≥0.998) between the ToF difference and applied stress and a high accuracy of less than 3% are demonstrated. Further, experimental testing of bolt stress under different practical conditions, such as bolt sizes, materials, and connection types validates the performance robustness and widespread applicability of our proposed PMUT-based ultrasonic stress sensing technique.
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (6) , 7548-7563
Modeling and Optimization of CMUTs Arrays for Improved Transmission and Reception Performance in Immersion
Capacitive micromechanical ultrasonic transducers (CMUTs) have widespread applications in ultrasonic imaging, therapeutic treatment, and underwater applications. Reasonable design of their array structures essentially determines the performance in aforementioned applications. However, there is a lack of a systematic investigation on the design strategies and effects of structure parameters of CMUTs arrays, significantly impeding their performance improvement. This paper constructs explicit and accurate analytical expressions for the main performances of CMUTs arrays in immersion by introducing the accurate distributed membrane deflection. Based on these theories, the influence laws of the aforementioned structure parameters on the CMUTs array performances are analyzed and summarized in detail, including the transmitting power, receiving sensitivity, focal length, beamwidth, etc. These theories and array performance variation rules are well validated by finite element method (FEM) simulations and experiment results of our fabricated CMUTs chips. It is demonstrated by the FEM simulation that, under specific array structural parameters, the fill factor has a significant improvement effect on CMUTs bandwidth (up to 173%). The multi arm spiral array and ring-shape array reduce the sidelobe level (62% less than that of conventional square arrays) and improve the transmitting power and receiving sensitivity (35% and 33% larger than that of conventional circular arrays), respectively. Based on these, CMUTs array design and optimization strategies are provided for typical ultrasonic applications. This study provides a theoretical basis for the design and application of CMUTs arrays in immersion, which will accelerate the development of CMUTs devices.
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (6) , 7548-7563
Modeling and Optimization of CMUTs Arrays for Improved Transmission and Reception Performance in Immersion
Capacitive micromechanical ultrasonic transducers (CMUTs) have widespread applications in ultrasonic imaging, therapeutic treatment, and underwater applications. Reasonable design of their array structures essentially determines the performance in aforementioned applications. However, there is a lack of a systematic investigation on the design strategies and effects of structure parameters of CMUTs arrays, significantly impeding their performance improvement. This paper constructs explicit and accurate analytical expressions for the main performances of CMUTs arrays in immersion by introducing the accurate distributed membrane deflection. Based on these theories, the influence laws of the aforementioned structure parameters on the CMUTs array performances are analyzed and summarized in detail, including the transmitting power, receiving sensitivity, focal length, beamwidth, etc. These theories and array performance variation rules are well validated by finite element method (FEM) simulations and experiment results of our fabricated CMUTs chips. It is demonstrated by the FEM simulation that, under specific array structural parameters, the fill factor has a significant improvement effect on CMUTs bandwidth (up to 173%). The multi arm spiral array and ring-shape array reduce the sidelobe level (62% less than that of conventional square arrays) and improve the transmitting power and receiving sensitivity (35% and 33% larger than that of conventional circular arrays), respectively. Based on these, CMUTs array design and optimization strategies are provided for typical ultrasonic applications. This study provides a theoretical basis for the design and application of CMUTs arrays in immersion, which will accelerate the development of CMUTs devices.
- 16 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12639, 127-132
Research on power spinning process of 2A12 aluminum alloy thin-walled parts
The effect of percent thickness reduction, feed rate and heat treatment on the forming process of 2A12 aluminum alloy thin-walled shell was studied. The experimental results show that the blank in H112 state was annealed at 380℃×1.5 h, followed by multiple passes spinning, followed by 330℃ × 0.5 h stress relief annealing in the intermediate process, and finally by vacuum air cooling at 495℃×40min. The ellipticity of workpiece can be controlled within 0.12 mm, the tensile strength reaches 490 ~ 517 MPa, and the elongation reaches 13.0~15.5%.
- 16 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12639, 127-132
Research on power spinning process of 2A12 aluminum alloy thin-walled parts
The effect of percent thickness reduction, feed rate and heat treatment on the forming process of 2A12 aluminum alloy thin-walled shell was studied. The experimental results show that the blank in H112 state was annealed at 380℃×1.5 h, followed by multiple passes spinning, followed by 330℃ × 0.5 h stress relief annealing in the intermediate process, and finally by vacuum air cooling at 495℃×40min. The ellipticity of workpiece can be controlled within 0.12 mm, the tensile strength reaches 490 ~ 517 MPa, and the elongation reaches 13.0~15.5%.
- 21 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
A Ferromagnetic Particle Sensor Based on a Honeycomb Permanent Magnet for High Precision and High Throughput
A multi-channel passive ferromagnetic particle inductive sensor is proposed, which is mainly composed of a honeycomb permanent magnet and a set of coils. The honeycomb magnet generates the same high gradient static magnetic field in each channel (a total of 7 channels, 6 surrounding and 1 center), which helps improve the sensor’s throughput while maintain high precision. An induced voltage model that includes most of the structural design parameters is proposed, which provides theoretical support for sensor optimization. The correctness of this model is verified by finite element simulation and experiments. The experimental results show that the detection performance of each channel is almost the same, which is expected to be further improved by setting a reference channel. Moreover, the sensor can detect 70 μm iron particles in a single channel of diameter 4 mm. The proposed sensor can reduce the influence of magnetic field radial uniformity on the induced signals, improve the detection precision, and achieve high throughput (about a 14-fold increase in throughput compared to our previous work). Its high precision and high throughput favor lots of lube oil detection.
- 21 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
A Ferromagnetic Particle Sensor Based on a Honeycomb Permanent Magnet for High Precision and High Throughput
A multi-channel passive ferromagnetic particle inductive sensor is proposed, which is mainly composed of a honeycomb permanent magnet and a set of coils. The honeycomb magnet generates the same high gradient static magnetic field in each channel (a total of 7 channels, 6 surrounding and 1 center), which helps improve the sensor’s throughput while maintain high precision. An induced voltage model that includes most of the structural design parameters is proposed, which provides theoretical support for sensor optimization. The correctness of this model is verified by finite element simulation and experiments. The experimental results show that the detection performance of each channel is almost the same, which is expected to be further improved by setting a reference channel. Moreover, the sensor can detect 70 μm iron particles in a single channel of diameter 4 mm. The proposed sensor can reduce the influence of magnetic field radial uniformity on the induced signals, improve the detection precision, and achieve high throughput (about a 14-fold increase in throughput compared to our previous work). Its high precision and high throughput favor lots of lube oil detection.
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (9) , 8565-8573
A Passive Ferro-Particle Sensor of Lube-Oil Based on Single Permanent Magnetic Ring
Inductive particle sensors have been widely used in wear monitoring for mechanical equipment, in which magnetostatic inductive sensor is the preferred choice to detect ferro-particles. However, the existing magnetostatic inductive particle sensors contain iron core components, and most of them are driven by external power supply, which makes it difficult to achieve lightweight and vulnerable to electromagnetic noise. Accordingly, this paper proposes a passive ferro-particle sensor of lube-oil based on single permanent magnetic ring. The corresponding mathematical model is established, and the analytical expression for the ferro-particle induced voltage is derived. To verify the validity of the model, the modeling results are compared with the finite element analysis. And the influence of the relevant parameters of the permanent magnet ring and coil on the induced voltage is discussed. The experimental results indicate that $30\mu $ m ferro-particles can be detected by this sensor at an oil flow rate of 510 ml/min. By comparing with the existing sensors, it can be concluded that the proposed sensor is of great significance to improve lightweight design and high-precision sensing for online ferro-particle monitoring in lube-oil.
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (9) , 8565-8573
A Passive Ferro-Particle Sensor of Lube-Oil Based on Single Permanent Magnetic Ring
Inductive particle sensors have been widely used in wear monitoring for mechanical equipment, in which magnetostatic inductive sensor is the preferred choice to detect ferro-particles. However, the existing magnetostatic inductive particle sensors contain iron core components, and most of them are driven by external power supply, which makes it difficult to achieve lightweight and vulnerable to electromagnetic noise. Accordingly, this paper proposes a passive ferro-particle sensor of lube-oil based on single permanent magnetic ring. The corresponding mathematical model is established, and the analytical expression for the ferro-particle induced voltage is derived. To verify the validity of the model, the modeling results are compared with the finite element analysis. And the influence of the relevant parameters of the permanent magnet ring and coil on the induced voltage is discussed. The experimental results indicate that $30\mu $ m ferro-particles can be detected by this sensor at an oil flow rate of 510 ml/min. By comparing with the existing sensors, it can be concluded that the proposed sensor is of great significance to improve lightweight design and high-precision sensing for online ferro-particle monitoring in lube-oil.