Mikio Bakke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mikio Bakke has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Naoki Kajiyama
Research and Development Division, Kikkoman Corporation, 399 Noda, Noda City, Chiba, 278-0037, Japan
4 shared publicationsKazuhiko Shimoji
Planning & Development Department Kikkoman Biochemifa Company Noda Chiba Japan
3 shared publicationsShigeya Suzuki
Planning & Development Department Kikkoman Biochemifa Company Noda Chiba Japan
3 shared publicationsChiaki Setoyama
2 shared publicationsErina Kirihara
Kikkoman General Hospital, Japan
2 shared publicationsRetsu Miura
2 shared publications
Latest Publications
- 3 August 2025
- Published by Wiley in Journal of Food Science
- Vol. 90 (8) , e70344
Development and Evaluation of Rapid and Simple Assay Method for α‐Amylase Activity in Rice Koji
A chromogenic substrate assay using 2‐chloro‐4‐nitrophenyl‐6 5 ‐azido‐6 5 ‐deoxy‐β‐maltopentaoside (G5 method) is one of the official analytical methods for α‐amylase activity in rice koji for sake‐brewing. Although it is useful because of its rapidity, simplicity, and accuracy, there are concerns about unavailability of the substrate in near future. In this study, an alternative assay using 4,6‐ O ‐ethylidene‐α‐4‐nitrophenyl‐maltoheptaoside (G7 method) was developed as a method that can be measured using the same procedure as the G5 method. α‐Amylase in the sample and the coupled enzymes, glucoamylase and α‐glucosidase, hydrolyzes the substrate, and the resulting chromophore, measured at 400 nm, was directly proportional to the α‐amylase activity. As the G7 method exhibited good precision, repeatability, and linearity with the G5 method for 41 kinds of rice koji ( y = 1.096 x , R 2 = 0.996), it is useful for the determination of α‐amylase activity in rice koji. When switching the G5 method to the G7 method, it should be noted that the G7 method tends to exhibit ca. 10% higher values than the G5 method as an average. Moreover, the ratios of the measurement values between the G7 and G5 methods can vary from 1.02 to 1.38 depending on the rice koji samples. Evaluation of K m values suggested that the catalytic properties of α‐amylase for the G7 and G5 methods can vary among rice koji samples. Therefore, if the G7 method is used instead of the G5 method, the comparison of assay results of the two methods for the target koji sample is preferable to ensure data compatibility. Practical Application: The previous chromogenic substrate assay, which is one of the official analytical methods for α‐amylase activity in rice koji for sake‐brewing, may become unavailable in near future. The alternative method was developed while maintaining simplicity and rapidity. It should be noted that the new method tends to exhibit ca. 10% higher values than the previous chromogenic substrate method. Checking the compatibility of two methods for each target koji seems to be desirable if the new method is used as the substitute for the previous method.
- 3 August 2025
- Published by Wiley in Journal of Food Science
- Vol. 90 (8) , e70344
Development and Evaluation of Rapid and Simple Assay Method for α‐Amylase Activity in Rice Koji
A chromogenic substrate assay using 2‐chloro‐4‐nitrophenyl‐6 5 ‐azido‐6 5 ‐deoxy‐β‐maltopentaoside (G5 method) is one of the official analytical methods for α‐amylase activity in rice koji for sake‐brewing. Although it is useful because of its rapidity, simplicity, and accuracy, there are concerns about unavailability of the substrate in near future. In this study, an alternative assay using 4,6‐ O ‐ethylidene‐α‐4‐nitrophenyl‐maltoheptaoside (G7 method) was developed as a method that can be measured using the same procedure as the G5 method. α‐Amylase in the sample and the coupled enzymes, glucoamylase and α‐glucosidase, hydrolyzes the substrate, and the resulting chromophore, measured at 400 nm, was directly proportional to the α‐amylase activity. As the G7 method exhibited good precision, repeatability, and linearity with the G5 method for 41 kinds of rice koji ( y = 1.096 x , R 2 = 0.996), it is useful for the determination of α‐amylase activity in rice koji. When switching the G5 method to the G7 method, it should be noted that the G7 method tends to exhibit ca. 10% higher values than the G5 method as an average. Moreover, the ratios of the measurement values between the G7 and G5 methods can vary from 1.02 to 1.38 depending on the rice koji samples. Evaluation of K m values suggested that the catalytic properties of α‐amylase for the G7 and G5 methods can vary among rice koji samples. Therefore, if the G7 method is used instead of the G5 method, the comparison of assay results of the two methods for the target koji sample is preferable to ensure data compatibility. Practical Application: The previous chromogenic substrate assay, which is one of the official analytical methods for α‐amylase activity in rice koji for sake‐brewing, may become unavailable in near future. The alternative method was developed while maintaining simplicity and rapidity. It should be noted that the new method tends to exhibit ca. 10% higher values than the previous chromogenic substrate method. Checking the compatibility of two methods for each target koji seems to be desirable if the new method is used as the substitute for the previous method.
- Open Access
- 3 May 2022
- Published by Elsevier in Journal of Food Protection
- Vol. 85 (7) , 1079-1095
A Comprehensive Analysis of ATP Tests: Practical Use and Recent Progress in the Total Adenylate Test for the Effective Monitoring of Hygiene
Rapid adenosine triphosphate (ATP) hygiene monitoring tests have been widely employed in the food industry to ensure that adequate cleanliness is maintained. In this article, the practical applications and limitations of these tests were discussed, while recent technological progress made to facilitate their more accurate control was also outlined. The presence of ATP on a surface indicates improper cleaning and the presence of contaminants, including organic debris and bacteria. In particular, food residues have been recognized as indicators of insufficient cleaning as well as direct hazards that may cause bacterial contamination because they may harbor bacteria, provide sources of nutrients for bacterial growth, interfere with the antimicrobial activity of disinfectants, and support the formation of a biofilm. Moreover, allergenic food residues on a surface may increase the risk of allergen cross-contact. However, it should be noted that ATP tests cannot detect bacteria or allergenic proteins directly. In order to ensure their efficient use, it is necessary to have an in-depth knowledge of their practical applications, methods of setting pass/fail limits, and the differences in the performance of various commercially available ATP tests. Conventional ATP tests, however, have certain limitations as ATP may be hydrolyzed to adenosine diphosphate (ADP) and adenosine monophosphate (AMP), which further hinders the identification of food residues. To overcome this problem, a total adenylate test was developed that could detect ATP+ADP+AMP (A3). The A3 test is suitable for the detection of adenylates from food residues and useful for the verification of hygiene levels. Using the A3 test in conjunction with other test methods, such as microorganism and food allergen tests, may be a useful strategy to diagnose the cause of uncleanliness and facilitate effective hygiene management.
- 3 May 2022
- Published by Elsevier in Journal of Food Protection
- Vol. 85 (7) , 1079-1095
Open AccessA Comprehensive Analysis of ATP Tests: Practical Use and Recent Progress in the Total Adenylate Test for the Effective Monitoring of Hygiene
Rapid adenosine triphosphate (ATP) hygiene monitoring tests have been widely employed in the food industry to ensure that adequate cleanliness is maintained. In this article, the practical applications and limitations of these tests were discussed, while recent technological progress made to facilitate their more accurate control was also outlined. The presence of ATP on a surface indicates improper cleaning and the presence of contaminants, including organic debris and bacteria. In particular, food residues have been recognized as indicators of insufficient cleaning as well as direct hazards that may cause bacterial contamination because they may harbor bacteria, provide sources of nutrients for bacterial growth, interfere with the antimicrobial activity of disinfectants, and support the formation of a biofilm. Moreover, allergenic food residues on a surface may increase the risk of allergen cross-contact. However, it should be noted that ATP tests cannot detect bacteria or allergenic proteins directly. In order to ensure their efficient use, it is necessary to have an in-depth knowledge of their practical applications, methods of setting pass/fail limits, and the differences in the performance of various commercially available ATP tests. Conventional ATP tests, however, have certain limitations as ATP may be hydrolyzed to adenosine diphosphate (ADP) and adenosine monophosphate (AMP), which further hinders the identification of food residues. To overcome this problem, a total adenylate test was developed that could detect ATP+ADP+AMP (A3). The A3 test is suitable for the detection of adenylates from food residues and useful for the verification of hygiene levels. Using the A3 test in conjunction with other test methods, such as microorganism and food allergen tests, may be a useful strategy to diagnose the cause of uncleanliness and facilitate effective hygiene management.
- 12 March 2020
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 103 (4) , 1090-1104
Validation Study of LuciPacTM A3 Surface for Hygiene Monitoring through Detection of ATP, ADP, and AMP from Stainless Steel Surfaces: AOAC Performance Tested MethodSM 051901
Background: The LuciPac A3 Surface Hygiene Monitoring System based on the detection of total adenylate, ATP+ADP+AMP (A3), has been developed by Kikkoman Biochemifa. Objective: This A3 swabbing assay kit was validated for Performance Tested MethodsSM (PTM) certification. Methods: The LuciPac A3 Surface Hygiene Monitoring System was evaluated for limit of detection (LOD) for each adenylate with pure analyte solutions, detection of food residues and microbial residues on stainless steel surfaces, interference by disinfectants, and selectivity of the method response. Results: Pure analyte studies performed by the method developer and the independent laboratory showed good linearity (R2 > 0.9854) and repeatability precision (RSDr < 20% for ≥2.5 fmol/assay). The LOD values for each adenylate were around 10 relative light units or 2.5 fmol/assay. The repeatability precision in the method developer laboratory for the matrix study (raw chicken breast, sliced deli ham, orange juice, yogurt, and apple pie) and the microbial study (Cronobacter sakazakii, Lactobacillus acidophilus, and Saccharomyces cerevisiae) were 8-30% and 10-35%, respectively. The repeatability precision of independent laboratory testing was 13-27% for orange juice and 16-43% for ham. Interference by several disinfectants indicate that rinsing is recommended to be performed after the use of sanitizing agents and before testing with LuciPac A3 Surface. Selectivity testing revealed that no positive interference and no inhibition were caused by adenylate analogues. Instrument variation, lot-to-lot consistency, accelerated stability (30°C, 5 weeks) were confirmed, and the method was shown to be robust against shaking time. Conclusions: The LuciPac A3 Surface has been successfully validated. Highlights: This A3 swabbing assay kit was qualified for PTM certification No. 051901.
- 12 March 2020
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 103 (4) , 1090-1104
Validation Study of LuciPacTM A3 Surface for Hygiene Monitoring through Detection of ATP, ADP, and AMP from Stainless Steel Surfaces: AOAC Performance Tested MethodSM 051901
Background: The LuciPac A3 Surface Hygiene Monitoring System based on the detection of total adenylate, ATP+ADP+AMP (A3), has been developed by Kikkoman Biochemifa. Objective: This A3 swabbing assay kit was validated for Performance Tested MethodsSM (PTM) certification. Methods: The LuciPac A3 Surface Hygiene Monitoring System was evaluated for limit of detection (LOD) for each adenylate with pure analyte solutions, detection of food residues and microbial residues on stainless steel surfaces, interference by disinfectants, and selectivity of the method response. Results: Pure analyte studies performed by the method developer and the independent laboratory showed good linearity (R2 > 0.9854) and repeatability precision (RSDr < 20% for ≥2.5 fmol/assay). The LOD values for each adenylate were around 10 relative light units or 2.5 fmol/assay. The repeatability precision in the method developer laboratory for the matrix study (raw chicken breast, sliced deli ham, orange juice, yogurt, and apple pie) and the microbial study (Cronobacter sakazakii, Lactobacillus acidophilus, and Saccharomyces cerevisiae) were 8-30% and 10-35%, respectively. The repeatability precision of independent laboratory testing was 13-27% for orange juice and 16-43% for ham. Interference by several disinfectants indicate that rinsing is recommended to be performed after the use of sanitizing agents and before testing with LuciPac A3 Surface. Selectivity testing revealed that no positive interference and no inhibition were caused by adenylate analogues. Instrument variation, lot-to-lot consistency, accelerated stability (30°C, 5 weeks) were confirmed, and the method was shown to be robust against shaking time. Conclusions: The LuciPac A3 Surface has been successfully validated. Highlights: This A3 swabbing assay kit was qualified for PTM certification No. 051901.
- Open Access
- 28 June 2019
- Vol. 60 (2) , E140-E146
Evaluation of the total adenylate (ATP + ADP + AMP) test for cleaning verification in healthcare settings.
Evaluation of cleaning methods is the first step in the prevention of healthcare-associated infections. ATP hygiene monitoring tests are widely used for assessing the effectiveness of cleaning procedures. The test is easy to use and gives immediate results, however, ATP can be metabolized and degraded to ADP and AMP. Recently, a total adenylate [ATP + ADP + AMP(A3)] monitoring test has been developed. Our objective was to evaluate the usefulness of the A3 test for cleaning verification in healthcare settings. The detection sensitivities of the ATP and the A3 tests were compared using blood, and debris derived from gloved-hand method and endoscopes immediately after endoscopic examination. The performance of the A3 test in monitoring cleanliness of high touch surfaces in the hospital and endoscopes at each cleaning step was also evaluated. For the hemolysate, the measurement values of the A3 test were stable, although ATP was promptly degraded. In debris from hands, the amount of A3 was 20 times higher than that of ATP. The detection sensitivities of the A3 test on residues derived from gastroscopes and colonoscopes were 3 and 8 times higher, respectively, than those from the ATP test. A field study indicated that a large number of microorganisms tend to show high A3 values on high touch surfaces in the hospital and on endoscopes. The A3 test showed higher detection sensitivities than the conventional ATP test for organic debris associated with healthcare settings.
- 28 June 2019
- Vol. 60 (2) , E140-E146
Open AccessEvaluation of the total adenylate (ATP + ADP + AMP) test for cleaning verification in healthcare settings.
Evaluation of cleaning methods is the first step in the prevention of healthcare-associated infections. ATP hygiene monitoring tests are widely used for assessing the effectiveness of cleaning procedures. The test is easy to use and gives immediate results, however, ATP can be metabolized and degraded to ADP and AMP. Recently, a total adenylate [ATP + ADP + AMP(A3)] monitoring test has been developed. Our objective was to evaluate the usefulness of the A3 test for cleaning verification in healthcare settings. The detection sensitivities of the ATP and the A3 tests were compared using blood, and debris derived from gloved-hand method and endoscopes immediately after endoscopic examination. The performance of the A3 test in monitoring cleanliness of high touch surfaces in the hospital and endoscopes at each cleaning step was also evaluated. For the hemolysate, the measurement values of the A3 test were stable, although ATP was promptly degraded. In debris from hands, the amount of A3 was 20 times higher than that of ATP. The detection sensitivities of the A3 test on residues derived from gastroscopes and colonoscopes were 3 and 8 times higher, respectively, than those from the ATP test. A field study indicated that a large number of microorganisms tend to show high A3 values on high touch surfaces in the hospital and on endoscopes. The A3 test showed higher detection sensitivities than the conventional ATP test for organic debris associated with healthcare settings.
- 1 January 2019
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 102 (1) , 164-180
Validation Study of Histamine Test for the Determination of Histamine in Selected Fish Products
Background: Since prescribed limits for histamine in fish have been set by various regulatory bodies around the world, the rapid, specific and easy determination of histamine is in high demand. Objective: The enzymatic histamine assay developed by Kikkoman Biochemifa Co. was validated. Methods: Fresh and frozen raw tuna, canned tuna in oil and water, and anchovy fish sauce were used for the validation study under the specific guidelines of the AOAC Research Institute Performance Tested MethodSM (PTM) program. Results: Good linearity (R2 > 0.9997) for histamine standard solutions, recovery rates (90.3–125.2%), and repeatability precisions (RSDr < 10%) were shown for all spiked tested matrixes. The claimed LOQ values, 20 and 10 mg/kg for solid fish and 160 and 80 mg/kg for fish sauce using a 1 and 2 cm optical path length spectrophotometer, respectively, were validated. The cross-reactivity test showed no positive interference of other biogenic amines, except for agmatine and putrescine. Moreover, no inhibition was confirmed among the 12 biogenic amines. Stability data supported the shelf life (42 months at 4°C), lot-to-lot consistency was demonstrated, and the method was shown to be robust. Independent laboratory testing using canned tuna in oil demonstrated that the recovery ranged from 93.5 to 124.7%, and the RSDr at all spike levels was Conclusions: The simple and rapid enzymatic histamine assay method has been successfully validated. Highlights: This histamine quantitative assay kit was qualified for PTM certification No. 041802.
- 1 January 2019
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 102 (1) , 164-180
Validation Study of Histamine Test for the Determination of Histamine in Selected Fish Products
Background: Since prescribed limits for histamine in fish have been set by various regulatory bodies around the world, the rapid, specific and easy determination of histamine is in high demand. Objective: The enzymatic histamine assay developed by Kikkoman Biochemifa Co. was validated. Methods: Fresh and frozen raw tuna, canned tuna in oil and water, and anchovy fish sauce were used for the validation study under the specific guidelines of the AOAC Research Institute Performance Tested MethodSM (PTM) program. Results: Good linearity (R2 > 0.9997) for histamine standard solutions, recovery rates (90.3–125.2%), and repeatability precisions (RSDr < 10%) were shown for all spiked tested matrixes. The claimed LOQ values, 20 and 10 mg/kg for solid fish and 160 and 80 mg/kg for fish sauce using a 1 and 2 cm optical path length spectrophotometer, respectively, were validated. The cross-reactivity test showed no positive interference of other biogenic amines, except for agmatine and putrescine. Moreover, no inhibition was confirmed among the 12 biogenic amines. Stability data supported the shelf life (42 months at 4°C), lot-to-lot consistency was demonstrated, and the method was shown to be robust. Independent laboratory testing using canned tuna in oil demonstrated that the recovery ranged from 93.5 to 124.7%, and the RSDr at all spike levels was Conclusions: The simple and rapid enzymatic histamine assay method has been successfully validated. Highlights: This histamine quantitative assay kit was qualified for PTM certification No. 041802.
- Open Access
- 1 May 2018
- Published by Elsevier in Journal of Food Protection
- Vol. 81 (5) , 729-737
Development of a Novel Hygiene Monitoring System Based on the Detection of Total Adenylate (ATP+ADP+AMP)
ATP is the universal energy molecule found in animals, plants, and microorganisms. ATP rapid hygiene monitoring tests have been employed in the food industry to ensure that adequate cleanliness is being maintained. However, because ATP is hydrolyzed to ADP and AMP by metabolic processes, by heat treatment, or under acidic or alkaline conditions, total adenylate (ATP+ADP+AMP [A3]) could be a more reliable sanitation indicator of food residues that may cause biofilm formation and allergen contamination. Therefore, a novel hygiene monitoring system to measure A3 was developed based on the luciferin-luciferase assay with the combination of two enzymes, pyruvate kinase and pyruvate phosphate dikinase, that can convert ADP into ATP and recycle AMP into ATP, respectively. The newly developed A3 assay system afforded stable bioluminescence signals and equivalent linear calibration curves between relative light units (RLU) and the amounts of ATP, ADP, and AMP, respectively. To verify the significance of t...
- 1 May 2018
- Published by Elsevier in Journal of Food Protection
- Vol. 81 (5) , 729-737
Open AccessDevelopment of a Novel Hygiene Monitoring System Based on the Detection of Total Adenylate (ATP+ADP+AMP)
ATP is the universal energy molecule found in animals, plants, and microorganisms. ATP rapid hygiene monitoring tests have been employed in the food industry to ensure that adequate cleanliness is being maintained. However, because ATP is hydrolyzed to ADP and AMP by metabolic processes, by heat treatment, or under acidic or alkaline conditions, total adenylate (ATP+ADP+AMP [A3]) could be a more reliable sanitation indicator of food residues that may cause biofilm formation and allergen contamination. Therefore, a novel hygiene monitoring system to measure A3 was developed based on the luciferin-luciferase assay with the combination of two enzymes, pyruvate kinase and pyruvate phosphate dikinase, that can convert ADP into ATP and recycle AMP into ATP, respectively. The newly developed A3 assay system afforded stable bioluminescence signals and equivalent linear calibration curves between relative light units (RLU) and the amounts of ATP, ADP, and AMP, respectively. To verify the significance of t...
- Open Access
- 1 January 2018
- Published by Japanese Society of Medical Instrumentation in Iryou kikigaku (The Japanese journal of medical instrumentation)
- Vol. 88 (3) , 357-363
Development of a Novel Hygiene Monitoring System Based on the Detection of Total Adenylate (ATP+ADP+AMP)
Adenosine triphosphate (ATP) tests are commonly used for cleanliness verification. However, since ATP is hydrolyzed to adenosine diphosphate (ADP) and adenosine monophosphate (AMP), total adenylate (ATP+ADP+AMP, A3) could be more reliable indicators. In this study, a novel enzymatic method to measure A3 was developed based on luciferin-luciferase assay with the combination of two enzymes, pyruvate kinase and pyruvate phosphate dikinase, which can convert ADP and AMP into ATP, respectively. The A3 method afforded equivalent linear calibration curves between the measurement output (Relative Light Units) and each of the amounts of ATP, ADP and AMP. The assays using conventional ATP tests and the A3 tests demonstrated that ATP in hemolysate was decomposed easily, on the other hand, the amounts of A3 were clearly maintained. Regarding sweat samples, the amount of A3 was 20 times higher than that of ATP. Moreover, the investigation for high touch surface samples showed good correlations between the A3 method and viable bacteria counts, and the amount of A3 was about 8 times higher than that of ATP on average. Therefore, the A3 tests appeared to be more reliable for the assessment of sanitation in healthcare settings than the conventional ATP assay.
- 1 January 2018
- Published by Japanese Society of Medical Instrumentation in Iryou kikigaku (The Japanese journal of medical instrumentation)
- Vol. 88 (3) , 357-363
Open AccessDevelopment of a Novel Hygiene Monitoring System Based on the Detection of Total Adenylate (ATP+ADP+AMP)
Adenosine triphosphate (ATP) tests are commonly used for cleanliness verification. However, since ATP is hydrolyzed to adenosine diphosphate (ADP) and adenosine monophosphate (AMP), total adenylate (ATP+ADP+AMP, A3) could be more reliable indicators. In this study, a novel enzymatic method to measure A3 was developed based on luciferin-luciferase assay with the combination of two enzymes, pyruvate kinase and pyruvate phosphate dikinase, which can convert ADP and AMP into ATP, respectively. The A3 method afforded equivalent linear calibration curves between the measurement output (Relative Light Units) and each of the amounts of ATP, ADP and AMP. The assays using conventional ATP tests and the A3 tests demonstrated that ATP in hemolysate was decomposed easily, on the other hand, the amounts of A3 were clearly maintained. Regarding sweat samples, the amount of A3 was 20 times higher than that of ATP. Moreover, the investigation for high touch surface samples showed good correlations between the A3 method and viable bacteria counts, and the amount of A3 was about 8 times higher than that of ATP on average. Therefore, the A3 tests appeared to be more reliable for the assessment of sanitation in healthcare settings than the conventional ATP assay.
- 19 November 2010
- Published by Wiley in FEBS Letters
- Vol. 585 (1) , 115-120
Identification, characterization, and molecular cloning of a novel hyaluronidase, a member of glycosyl hydrolase family 16, fromPenicilliumspp
Hyaluronidase (HAase) activity was detected in the culture supernatants of Penicillium purpurogenum and Penicillium funiculosum. The HAase from Penicillium spp. (HAase-P) was a hyaluronate 4-glycanohydrolase, which catalyzed the endolytic hydrolysis of the β-1,4 glycosidic linkage, as do vertebrate HAases. The gene encoding HAase-P was cloned and expressed in Escherichia coli. According to homology analyses of the deduced amino acid sequences, HAase-P is not classified into any of the known HAase groups, but belongs to glycoside hydrolase family 16, which includes endo-β-1,3(4)-glucanase. Regarding the substrate specificities, no chondroitinase and glucanase activities were detected. Judging from homology analyses and enzymatic properties, HAase-P seems to be a new type of HAase.
- 19 November 2010
- Published by Wiley in FEBS Letters
- Vol. 585 (1) , 115-120
Identification, characterization, and molecular cloning of a novel hyaluronidase, a member of glycosyl hydrolase family 16, fromPenicilliumspp
Hyaluronidase (HAase) activity was detected in the culture supernatants of Penicillium purpurogenum and Penicillium funiculosum. The HAase from Penicillium spp. (HAase-P) was a hyaluronate 4-glycanohydrolase, which catalyzed the endolytic hydrolysis of the β-1,4 glycosidic linkage, as do vertebrate HAases. The gene encoding HAase-P was cloned and expressed in Escherichia coli. According to homology analyses of the deduced amino acid sequences, HAase-P is not classified into any of the known HAase groups, but belongs to glycoside hydrolase family 16, which includes endo-β-1,3(4)-glucanase. Regarding the substrate specificities, no chondroitinase and glucanase activities were detected. Judging from homology analyses and enzymatic properties, HAase-P seems to be a new type of HAase.
- 1 November 2007
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics
- Vol. 1774 (11) , 1395-1401
N1,N12-Diacetylspermine oxidase from Debaryomyces hansenii T-42: Purification, characterization, molecular cloning and gene expression
- 1 November 2007
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics
- Vol. 1774 (11) , 1395-1401
N1,N12-Diacetylspermine oxidase from Debaryomyces hansenii T-42: Purification, characterization, molecular cloning and gene expression