Martina Schmeling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martina Schmeling has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Tinamarie Fosco
Department Of Chemistry, Loyola University Chicago, Chicago, USA
3 shared publications- Igor V. Veryovkin
Argonne National Laboratory, Materials Science Division, Argonne, IL 60439, USA
2 shared publications Katrina Binaku
Loyola University Chicago
2 shared publications- Michelle Gende
Department of Chemistry and Biochemistry, Loyola University Chicago
2 shared publications A. Tovar
Department of Chemistry and Biochemistry Loyola University Chicago Chicago Illinois USA
1 shared publication- Alyssa Tovar
Department of Chemistry and Biochemistry, Loyola University Chicago
1 shared publication
Latest Publications
- 9 December 2024
- Published by Taylor & Francis in Current Eye Research
- Vol. 50 (3) , 264-275
Assessing Chronic Heavy Metal Exposure by Analysis of Human Cataract Specimens and the Relationship to Metabolic Profiles
With age, the mammalian lens forms successive layers of crystallin protein fibers which infoliate with lens growth and development. As heavy metals generally bind to tissue protein, heavy metals are posited to sequester within the lens with age. Therefore, this study aims to compare heavy metals in human crystalline lens of older adults to known physiologic blood and urine levels and assess the association between concentrations in the lens and metabolic biomarkers. Consecutive lens specimens obtained during cataract surgery by phacoemulsification were subjected to atomic spectrometry for heavy metal content. A one-sample t-test compared heavy metals in lens to known physiologic blood and urine concentrations. Linear regression models assessed the association between heavy metals and biomarkers of metabolic function. Linear discriminant analysis assessed the classification of gender and smoking status based on multiple and individual heavy metals. All heavy metal levels were elevated in lens specimens compared to blood and urine with the exception of iron (p < 0.0001). Lens titanium and copper were positively associated with blood-urea nitrogen (Titanium: = 1.14, p = 0.04, Copper: = 1.12, p = 0.03. Lens copper was positively associated with creatinine ( = 1.10; p = 0.02), but negatively associated with glomerular filtration rate ( = 0.89; p = 0.02). Lens chromium and lead were positively associated with albumin (Chromium: = 1.03, p = 0.03; Lead: = 1.02, p = 0.04). Lens nickel was positively associated with bilirubin ( = 1.14; p = 0.03). Classification based on multiple or individual heavy metals for gender and smoking status was not statistically significant. Our results suggest the human crystalline lens accumulates heavy metals with age and demonstrate the correlation between abnormality of metabolic function and heavy metal deposition in older adult lens.- 9 December 2024
- Published by Taylor & Francis in Current Eye Research
- Vol. 50 (3) , 264-275
Assessing Chronic Heavy Metal Exposure by Analysis of Human Cataract Specimens and the Relationship to Metabolic Profiles
With age, the mammalian lens forms successive layers of crystallin protein fibers which infoliate with lens growth and development. As heavy metals generally bind to tissue protein, heavy metals are posited to sequester within the lens with age. Therefore, this study aims to compare heavy metals in human crystalline lens of older adults to known physiologic blood and urine levels and assess the association between concentrations in the lens and metabolic biomarkers. Consecutive lens specimens obtained during cataract surgery by phacoemulsification were subjected to atomic spectrometry for heavy metal content. A one-sample t-test compared heavy metals in lens to known physiologic blood and urine concentrations. Linear regression models assessed the association between heavy metals and biomarkers of metabolic function. Linear discriminant analysis assessed the classification of gender and smoking status based on multiple and individual heavy metals. All heavy metal levels were elevated in lens specimens compared to blood and urine with the exception of iron (p < 0.0001). Lens titanium and copper were positively associated with blood-urea nitrogen (Titanium: = 1.14, p = 0.04, Copper: = 1.12, p = 0.03. Lens copper was positively associated with creatinine ( = 1.10; p = 0.02), but negatively associated with glomerular filtration rate ( = 0.89; p = 0.02). Lens chromium and lead were positively associated with albumin (Chromium: = 1.03, p = 0.03; Lead: = 1.02, p = 0.04). Lens nickel was positively associated with bilirubin ( = 1.14; p = 0.03). Classification based on multiple or individual heavy metals for gender and smoking status was not statistically significant. Our results suggest the human crystalline lens accumulates heavy metals with age and demonstrate the correlation between abnormality of metabolic function and heavy metal deposition in older adult lens.- Open Access
- 24 June 2024
- Published by Wiley in X-Ray Spectrometry
- Vol. 54 (2) , 118-126
Biomonitoring of urban industrial pollution using total reflection X‐ray fluorescence
Environmental pollution as a result of industrial activity is widespread in many urban areas including Chicago. In an effort to evaluate the heavy metal fraction originating from industrial activities, plant samples of Daucus Carota or wild carrot were collected at or adjacent to six sites located in two of Chicago's designated industrial corridors. Plants, especially herbaceous species, have been deemed suitable as environmental pollution monitors as they are able to provide information about the heavy metal fraction accessible to biota. The leaves of Daucus Carota were acid digested and analyzed with total reflection X‐ray fluorescence spectrometry TXRF. The results showed elevated heavy metal mass fractions for at least one collection site which is close to an operational railyard. Other studies investigating heavy metals in proximity to railroad operations found elevated mass fractions for several elements, but specifically manganese as well. This suggests that abrasion from shunting and breaking releases certain pollutants into the local environment. The data were compared with studies executed in Rome, Italy, and Pakistan, which used Daucus Carota to evaluate heavy metal pollution. It was found that the heavy metal mass fractions obtained for Chicago were higher for some elements indicating an increased pollutant burden for these elements. The same samples were also analyzed by graphite furnace atomic absorption spectrometry GFAAS for the elements copper and lead and the data compared. Those two elements were chosen as they were present at each location and GFAAS has proven to be highly sensitive for them. It was found that the two methods provided comparable results for copper, whereas for lead, TXRF overestimated the mass fractions most likely due to limitations of the spectra evaluation software. The analysis of a certified reference material ‘BCR 679 white cabbage’ showed that most data obtained by TXRF were in good agreement with the certified values, with the exception of lead, which was not certified. However, since GFAAS has high sensitivity toward lead and is considered reference method for that element by regulatory agencies, a comparison between GFAAS and TXRF data for lead in the same sample can serve as good indicator for TXRF performance.
- 24 June 2024
- Published by Wiley in X-Ray Spectrometry
- Vol. 54 (2) , 118-126
Open AccessBiomonitoring of urban industrial pollution using total reflection X‐ray fluorescence
Environmental pollution as a result of industrial activity is widespread in many urban areas including Chicago. In an effort to evaluate the heavy metal fraction originating from industrial activities, plant samples of Daucus Carota or wild carrot were collected at or adjacent to six sites located in two of Chicago's designated industrial corridors. Plants, especially herbaceous species, have been deemed suitable as environmental pollution monitors as they are able to provide information about the heavy metal fraction accessible to biota. The leaves of Daucus Carota were acid digested and analyzed with total reflection X‐ray fluorescence spectrometry TXRF. The results showed elevated heavy metal mass fractions for at least one collection site which is close to an operational railyard. Other studies investigating heavy metals in proximity to railroad operations found elevated mass fractions for several elements, but specifically manganese as well. This suggests that abrasion from shunting and breaking releases certain pollutants into the local environment. The data were compared with studies executed in Rome, Italy, and Pakistan, which used Daucus Carota to evaluate heavy metal pollution. It was found that the heavy metal mass fractions obtained for Chicago were higher for some elements indicating an increased pollutant burden for these elements. The same samples were also analyzed by graphite furnace atomic absorption spectrometry GFAAS for the elements copper and lead and the data compared. Those two elements were chosen as they were present at each location and GFAAS has proven to be highly sensitive for them. It was found that the two methods provided comparable results for copper, whereas for lead, TXRF overestimated the mass fractions most likely due to limitations of the spectra evaluation software. The analysis of a certified reference material ‘BCR 679 white cabbage’ showed that most data obtained by TXRF were in good agreement with the certified values, with the exception of lead, which was not certified. However, since GFAAS has high sensitivity toward lead and is considered reference method for that element by regulatory agencies, a comparison between GFAAS and TXRF data for lead in the same sample can serve as good indicator for TXRF performance.
- Open Access
- 3 May 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (5) , e0267775
Development of an analytical method for determination of lead and cadmium in biological materials by GFAAS using Escherichia coli as model substance
In this work, an analytical method was developed for the determination of lead and cadmium in biological samples using graphite furnace atomic absorption spectrometry. Escherichia coli (E. coli) was chosen as model substance for this purpose as it is readily available in most laboratories and can be quickly and easily prepared with a high turnaround rate. Four different sample preparation methods were initially evaluated with respect to percent recovery, limit of detection, and limit of quantification, and the most promising one was developed further. The final process involving microwave assisted digestion of the sample with nitric acid and hydrogen peroxide showed high recovery, repeatability, and specificity. The process was first applied to lead and then extended for the determination of cadmium in the same E. coli substrates. Finally, to validate the process, a certified references material was analyzed, and the results obtained were evaluated with respect to accuracy by comparing them to the reported ones.
- 3 May 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (5) , e0267775
Open AccessDevelopment of an analytical method for determination of lead and cadmium in biological materials by GFAAS using Escherichia coli as model substance
In this work, an analytical method was developed for the determination of lead and cadmium in biological samples using graphite furnace atomic absorption spectrometry. Escherichia coli (E. coli) was chosen as model substance for this purpose as it is readily available in most laboratories and can be quickly and easily prepared with a high turnaround rate. Four different sample preparation methods were initially evaluated with respect to percent recovery, limit of detection, and limit of quantification, and the most promising one was developed further. The final process involving microwave assisted digestion of the sample with nitric acid and hydrogen peroxide showed high recovery, repeatability, and specificity. The process was first applied to lead and then extended for the determination of cadmium in the same E. coli substrates. Finally, to validate the process, a certified references material was analyzed, and the results obtained were evaluated with respect to accuracy by comparing them to the reported ones.
- Open Access
- 30 March 2019
- Published by Walter de Gruyter GmbH in Physical Sciences Reviews
- Vol. 4 (7)
Total reflection X-ray fluorescence
Total reflection X-ray fluorescence (TXRF) spectrometry is a non-destructive and surface sensitive multi-element analytical method based on energy dispersive X-ray fluorescence spectrometry with detection limits in the lower picogram range. It utilizes the total reflection of the primary X-ray beam at or below the critical angle of incidence. At this angle, the fluorescence intensity is substantially enhanced for samples present as small granular residue or as thin homogenous layer deposited at the surface of a thick substrate. Generally, two types of application exist: micro- and trace-analysis as well as surface and thin-layer analysis. For micro- and trace-analysis, a small amount of the solid or liquid sample is deposited on an optically flat substrate, typically quartz or polycarbonate. The dried residue is analyzed at a fixed angle setting slightly below the critical angle. Quantification is carried out by means of internal standardization. For surface and thin-layer analysis, the surface of an optically flat substrate is scanned. Variations of the incident angle of the primary X-ray beam provide information about the type and sometimes also the amount of material present at or slightly below the surface of the substrate. Major fields of application are environmental samples, biological tissues, objects of cultural heritage, semiconductors and thin-layered materials and films.
- 30 March 2019
- Published by Walter de Gruyter GmbH in Physical Sciences Reviews
- Vol. 4 (7)
Open AccessTotal reflection X-ray fluorescence
Total reflection X-ray fluorescence (TXRF) spectrometry is a non-destructive and surface sensitive multi-element analytical method based on energy dispersive X-ray fluorescence spectrometry with detection limits in the lower picogram range. It utilizes the total reflection of the primary X-ray beam at or below the critical angle of incidence. At this angle, the fluorescence intensity is substantially enhanced for samples present as small granular residue or as thin homogenous layer deposited at the surface of a thick substrate. Generally, two types of application exist: micro- and trace-analysis as well as surface and thin-layer analysis. For micro- and trace-analysis, a small amount of the solid or liquid sample is deposited on an optically flat substrate, typically quartz or polycarbonate. The dried residue is analyzed at a fixed angle setting slightly below the critical angle. Quantification is carried out by means of internal standardization. For surface and thin-layer analysis, the surface of an optically flat substrate is scanned. Variations of the incident angle of the primary X-ray beam provide information about the type and sometimes also the amount of material present at or slightly below the surface of the substrate. Major fields of application are environmental samples, biological tissues, objects of cultural heritage, semiconductors and thin-layered materials and films.
- Open Access
- 2 September 2017
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 10 (10) , 1227-1236
Multivariate statistical analyses of air pollutants and meteorology in Chicago during summers 2010-2012
- 2 September 2017
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 10 (10) , 1227-1236
Open AccessMultivariate statistical analyses of air pollutants and meteorology in Chicago during summers 2010-2012
- 1 October 2016
- Published by Elsevier in Surface Science
- Vol. 652, 334-343
Metal impurity-assisted formation of nanocone arrays on Si by low energy ion-beam irradiation
- 1 October 2016
- Published by Elsevier in Surface Science
- Vol. 652, 334-343
Metal impurity-assisted formation of nanocone arrays on Si by low energy ion-beam irradiation
- Open Access
- 24 April 2014
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 29 (2) , 155-158
Heavy metal analysis in lens and aqueous humor of cataract patients by total reflection X-ray fluorescence spectrometry
The human eye is continuously exposed to the environment yet little is known about how much of toxins, specifically heavy metals are present in its different parts and how they influence vision and acuity. To shed light into this subject, aqueous humor and lens samples were collected from 14 cataract patients to study the presence and concentration of selected metals in the eye. Subjects undergoing routine cataract surgery were consecutively enrolled for study by simple random sampling. Prior to surgery, subject demographic were compiled. The surgical procedure involved small incision cataract removal using phacoemulsification. During the procedure, a small aliquot of aqueous humor was retained for analysis, whereas homogenized lens fragments were obtained during phacoemulsification. A balanced salt solution was used as control for each set of samples. Both ocular specimens were analyzed by total reflection X-ray fluorescence spectrometry after dilution and addition of an internal standard. The data obtained show substantial variations in elemental signature between the two media (aqueous humor and lens) and the patients themselves. Most commonly found heavy metals in both types of media were chromium and manganese. Barium was found in the lens, but not in aqueous tissue, whereas nickel was found only in the aqueous humor. Concentrations were generally higher in aqueous samples. Further study and increased sample size are required to more accurately elucidate the relationship between systemic and ocular metal accumulation and the impact of metal accumulation on measures of visual function and ocular disease.
- 24 April 2014
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 29 (2) , 155-158
Open AccessHeavy metal analysis in lens and aqueous humor of cataract patients by total reflection X-ray fluorescence spectrometry
The human eye is continuously exposed to the environment yet little is known about how much of toxins, specifically heavy metals are present in its different parts and how they influence vision and acuity. To shed light into this subject, aqueous humor and lens samples were collected from 14 cataract patients to study the presence and concentration of selected metals in the eye. Subjects undergoing routine cataract surgery were consecutively enrolled for study by simple random sampling. Prior to surgery, subject demographic were compiled. The surgical procedure involved small incision cataract removal using phacoemulsification. During the procedure, a small aliquot of aqueous humor was retained for analysis, whereas homogenized lens fragments were obtained during phacoemulsification. A balanced salt solution was used as control for each set of samples. Both ocular specimens were analyzed by total reflection X-ray fluorescence spectrometry after dilution and addition of an internal standard. The data obtained show substantial variations in elemental signature between the two media (aqueous humor and lens) and the patients themselves. Most commonly found heavy metals in both types of media were chromium and manganese. Barium was found in the lens, but not in aqueous tissue, whereas nickel was found only in the aqueous humor. Concentrations were generally higher in aqueous samples. Further study and increased sample size are required to more accurately elucidate the relationship between systemic and ocular metal accumulation and the impact of metal accumulation on measures of visual function and ocular disease.
- 1 February 2013
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 185 (9) , 7295-7308
Statistical analysis of aerosol species, trace gasses, and meteorology in Chicago
- 1 February 2013
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 185 (9) , 7295-7308
Statistical analysis of aerosol species, trace gasses, and meteorology in Chicago
- 15 June 2012
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 27 (2) , 75-78
Steps toward accurate large-area analyses of Genesis solar wind samples: evaluation of surface cleaning methods using total reflection X-ray fluorescence spectrometry
Total reflection X-ray fluorescence spectrometry (TXRF) was used to analyze residual surface contamination on Genesis solar wind samples and to evaluate different cleaning methods. To gauge the suitability of a cleaning method, two samples were analyzed following cleaning by lab-based TXRF. The analysis comprised an overview and a crude manual mapping of the samples by orienting them with respect to the incident X-ray beam in such a way that different regions were covered. The results show that cleaning with concentrated hydrochloric acid and a combination of hydrochloric acid and hydrofluoric acid decreased persistent inorganic contaminants substantially on one sample. The application of CO 2 snow for surface cleaning tested on the other sample appears to be effective in removing one persistent Genesis contaminant, namely germanium. Unfortunately, the TXRF analysis results of the second sample were impacted by relatively high background contamination. This was mostly due to the relatively small sample size and that the solar wind collector was already mounted with silver glue for resonance ion mass spectrometry (RIMS) on an aluminium stub. Further studies are planned to eliminate this problem. In an effort to identify the location of very persistent contaminants, selected samples were also subjected to environmental scanning electron microscopy. The results showed excellent agreement with TXRF analysis.
- 15 June 2012
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 27 (2) , 75-78
Steps toward accurate large-area analyses of Genesis solar wind samples: evaluation of surface cleaning methods using total reflection X-ray fluorescence spectrometry
Total reflection X-ray fluorescence spectrometry (TXRF) was used to analyze residual surface contamination on Genesis solar wind samples and to evaluate different cleaning methods. To gauge the suitability of a cleaning method, two samples were analyzed following cleaning by lab-based TXRF. The analysis comprised an overview and a crude manual mapping of the samples by orienting them with respect to the incident X-ray beam in such a way that different regions were covered. The results show that cleaning with concentrated hydrochloric acid and a combination of hydrochloric acid and hydrofluoric acid decreased persistent inorganic contaminants substantially on one sample. The application of CO 2 snow for surface cleaning tested on the other sample appears to be effective in removing one persistent Genesis contaminant, namely germanium. Unfortunately, the TXRF analysis results of the second sample were impacted by relatively high background contamination. This was mostly due to the relatively small sample size and that the solar wind collector was already mounted with silver glue for resonance ion mass spectrometry (RIMS) on an aluminium stub. Further studies are planned to eliminate this problem. In an effort to identify the location of very persistent contaminants, selected samples were also subjected to environmental scanning electron microscopy. The results showed excellent agreement with TXRF analysis.
- 23 January 2007
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 130 (1-3) , 187-199
Determination of Water-soluble Atmospheric Aerosols Using Ion Chromatography
A field study was established to investigate the chemical composition of atmospheric aerosols in Chicago, IL. One goal of this study was to determine the influence of precursor trace gases and local meteorology on concentrations of secondary aerosol ionic species. This paper describes the method details, shows the method is analytically valid, and reports overall as well as some specific results found during the field study. Two particulate air samples were collected per day onto quartz fiber filters at the Loyola University Chicago Air Station during the summer months in 2002–2004. In parallel, mixing ratios of ozone and nitrogen oxides were monitored and weather parameters were recorded. Particulates were extracted from the filter substrates and the subsequent solutions were analyzed by ion chromatography for anions, including low molecular weight organic acids, and cations. A washing procedure was implemented to reduce the high background values of the quartz fiber filters. Method validation showed that the collection method was efficient for all ions with exception of nitrate, whose efficiency of 70% indicated losses caused by volatilization. The extraction method also proved efficient for both field and laboratory samples, and the repeatability of the method was high with relative standard deviations less than 10% for all ions. Reproducibility of the results was determined by comparison of sulfate to sulfur analyzed by total reflection X-ray fluorescence spectrometry and proved to be high as well. Concentrations differed significantly between the three summer studies due to varying levels of precursor species as a consequence of distinct temperatures and wind direction profiles.
- 23 January 2007
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 130 (1-3) , 187-199
Determination of Water-soluble Atmospheric Aerosols Using Ion Chromatography
A field study was established to investigate the chemical composition of atmospheric aerosols in Chicago, IL. One goal of this study was to determine the influence of precursor trace gases and local meteorology on concentrations of secondary aerosol ionic species. This paper describes the method details, shows the method is analytically valid, and reports overall as well as some specific results found during the field study. Two particulate air samples were collected per day onto quartz fiber filters at the Loyola University Chicago Air Station during the summer months in 2002–2004. In parallel, mixing ratios of ozone and nitrogen oxides were monitored and weather parameters were recorded. Particulates were extracted from the filter substrates and the subsequent solutions were analyzed by ion chromatography for anions, including low molecular weight organic acids, and cations. A washing procedure was implemented to reduce the high background values of the quartz fiber filters. Method validation showed that the collection method was efficient for all ions with exception of nitrate, whose efficiency of 70% indicated losses caused by volatilization. The extraction method also proved efficient for both field and laboratory samples, and the repeatability of the method was high with relative standard deviations less than 10% for all ions. Reproducibility of the results was determined by comparison of sulfate to sulfur analyzed by total reflection X-ray fluorescence spectrometry and proved to be high as well. Concentrations differed significantly between the three summer studies due to varying levels of precursor species as a consequence of distinct temperatures and wind direction profiles.