Ilseob Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ilseob Song has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Yangmo Yoo
Sogang University
8 shared publications - Hyunwoo Cho
Department of Electronic Engineering, Sogang University, Seoul 04107, Republic of Korea
4 shared publications - Jihun Jang
Sogang University
4 shared publications - Jinbum Kang
Department of Biomedical Software Engineering, The Catholic University of Korea, Bucheon 14662, South Korea
3 shared publications - Daehyun Park
Department of Electronic Engineering, Sogang University, Seoul, Republic of Korea
1 shared publication - Dooyoung Go
Department of Electronic Engineering, Sogang University, Seoul 04107, Korea
1 shared publication
Latest Publications
- 25 June 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (4) , 393-401
A new single-sagittal-plane deep learning approach for continuous bladder volume monitoring: a feasibility study
Conventional ultrasound-based bladder volumetry multiplies three orthogonal diameters and applies a heuristic shape coefficient. This approach requires near-simultaneous transverse and sagittal imaging and is vulnerable to interplane misregistration and coefficient-dependent bias. This study evaluated whether a single sagittal B-mode image can provide accurate, patient-specific bladder volume estimation by leveraging sagittal morphology, perivesical echotexture, and latent image features associated with overall bladder geometry. In this Institutional Review Board-approved, single-center study, participants were scanned in the supine position, and bladder volume was referenced to immediate Foley catheter drainage. Segmentation masks were independently annotated by two sonographers and adjudicated by a urologist. Maximum sagittal length was extracted using OpenCV and included as an auxiliary scalar input. A single-stage deep learning model was developed that receives one sagittal B-mode image and its expert-annotated segmentation mask as input. The model used a lightweight convolutional neural network backbone with integrated self-attention to capture global echotextural cues. Performance on a held-out test set (n=53) was assessed using linear regression, Bland-Altman analysis, mean absolute error, and mean absolute percentage error. The model demonstrated a strong correlation with catheter-derived volumes (R²=0.87). Bland-Altman analysis showed a mean bias of -3.96±48.44 mL, with limits of agreement from -98.90 to +90.98 mL. Stratified error analysis showed a mean absolute error of 14.15 mL for volumes of 0-100 mL and a mean absolute percentage error of 16.64% for volumes ≥100 mL. Attention maps emphasized the bladder wall and perivesical soft tissues, suggesting reliance on contextual echotexture. A deep learning framework using a single sagittal plane estimated bladder volume with accuracy approaching that of two-plane techniques while simplifying image acquisition and eliminating reliance on fixed shape coefficients.
- 25 June 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (4) , 393-401
A new single-sagittal-plane deep learning approach for continuous bladder volume monitoring: a feasibility study
Conventional ultrasound-based bladder volumetry multiplies three orthogonal diameters and applies a heuristic shape coefficient. This approach requires near-simultaneous transverse and sagittal imaging and is vulnerable to interplane misregistration and coefficient-dependent bias. This study evaluated whether a single sagittal B-mode image can provide accurate, patient-specific bladder volume estimation by leveraging sagittal morphology, perivesical echotexture, and latent image features associated with overall bladder geometry. In this Institutional Review Board-approved, single-center study, participants were scanned in the supine position, and bladder volume was referenced to immediate Foley catheter drainage. Segmentation masks were independently annotated by two sonographers and adjudicated by a urologist. Maximum sagittal length was extracted using OpenCV and included as an auxiliary scalar input. A single-stage deep learning model was developed that receives one sagittal B-mode image and its expert-annotated segmentation mask as input. The model used a lightweight convolutional neural network backbone with integrated self-attention to capture global echotextural cues. Performance on a held-out test set (n=53) was assessed using linear regression, Bland-Altman analysis, mean absolute error, and mean absolute percentage error. The model demonstrated a strong correlation with catheter-derived volumes (R²=0.87). Bland-Altman analysis showed a mean bias of -3.96±48.44 mL, with limits of agreement from -98.90 to +90.98 mL. Stratified error analysis showed a mean absolute error of 14.15 mL for volumes of 0-100 mL and a mean absolute percentage error of 16.64% for volumes ≥100 mL. Attention maps emphasized the bladder wall and perivesical soft tissues, suggesting reliance on contextual echotexture. A deep learning framework using a single sagittal plane estimated bladder volume with accuracy approaching that of two-plane techniques while simplifying image acquisition and eliminating reliance on fixed shape coefficients.
- Open Access
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 80247-80257
Fully Automated Bladder Volume Measurement System Using a T-Shaped Ultrasound Probe and Free-Hand Motion-Based 3D Reconstruction
Accurate measurement of bladder volume is critical for the effective management of urinary diseases. Among the available modalities, ultrasound imaging is favored due to its cost-effectiveness, non-ionizing nature, and capability to provide real-time bladder volume measurements. To enhance convenience in clinical practice, ultrasound bladder scanners have been developed and adopted in various settings. However, wobbling probe devices present significant limitations, including their inability to provide real-time images, the requirement for pre-scan alignment to ensure precise probe positioning, and the necessity for multiple volume estimations to achieve measurement accuracy. Additionally, conventional image-based estimations utilizing standard ultrasound machines or recently developed bladder scanners face challenges related to the use of shape coefficients. These methods typically rely on two image planes, which fail to fully capture the bladder’s shape, resulting in considerable errors in volume estimation when compensating for shape with coefficients. To overcome these limitations, this study proposes a novel automated bladder volume measurement technique that employs a T-shaped cross-array ultrasound probe in conjunction with free-hand motion-based 3D reconstruction. The T-shaped cross-array enables the simultaneous acquisition of sagittal and transverse view images of the bladder. By moving the probe at the suprapubic region, continuously acquired sagittal images can be combined into a 3D volume, with motion compensation achieved via the transverse images. Consequently, the proposed method can accurately reconstruct the entire bladder and measure its volume without the need for shape correction coefficients, while also reducing errors associated with ultrasound probe positioning. The proposed methodology was validated through phantom experiments simulating both spherical and irregular bladder shapes. The results demonstrated an error rate ranging from -8.8% to +5.6% when compared to the ground truth, indicating the method’s high accuracy. These results indicate that the proposed method, in conjunction with the developed array and system, has the potential to reduce the necessity for catheterization in clinical settings and enhance clinical decision-making.
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 80247-80257
Open AccessFully Automated Bladder Volume Measurement System Using a T-Shaped Ultrasound Probe and Free-Hand Motion-Based 3D Reconstruction
Accurate measurement of bladder volume is critical for the effective management of urinary diseases. Among the available modalities, ultrasound imaging is favored due to its cost-effectiveness, non-ionizing nature, and capability to provide real-time bladder volume measurements. To enhance convenience in clinical practice, ultrasound bladder scanners have been developed and adopted in various settings. However, wobbling probe devices present significant limitations, including their inability to provide real-time images, the requirement for pre-scan alignment to ensure precise probe positioning, and the necessity for multiple volume estimations to achieve measurement accuracy. Additionally, conventional image-based estimations utilizing standard ultrasound machines or recently developed bladder scanners face challenges related to the use of shape coefficients. These methods typically rely on two image planes, which fail to fully capture the bladder’s shape, resulting in considerable errors in volume estimation when compensating for shape with coefficients. To overcome these limitations, this study proposes a novel automated bladder volume measurement technique that employs a T-shaped cross-array ultrasound probe in conjunction with free-hand motion-based 3D reconstruction. The T-shaped cross-array enables the simultaneous acquisition of sagittal and transverse view images of the bladder. By moving the probe at the suprapubic region, continuously acquired sagittal images can be combined into a 3D volume, with motion compensation achieved via the transverse images. Consequently, the proposed method can accurately reconstruct the entire bladder and measure its volume without the need for shape correction coefficients, while also reducing errors associated with ultrasound probe positioning. The proposed methodology was validated through phantom experiments simulating both spherical and irregular bladder shapes. The results demonstrated an error rate ranging from -8.8% to +5.6% when compared to the ground truth, indicating the method’s high accuracy. These results indicate that the proposed method, in conjunction with the developed array and system, has the potential to reduce the necessity for catheterization in clinical settings and enhance clinical decision-making.
- Open Access
- 26 April 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (5) , 525
A Lightweight Deep Learning Network on a System-on-Chip for Wearable Ultrasound Bladder Volume Measurement Systems: Preliminary Study
Bladder volume assessments are crucial for managing urinary disorders. Ultrasound imaging (US) is a preferred noninvasive, cost-effective imaging modality for bladder observation and volume measurements. However, the high operator dependency of US is a major challenge due to the difficulty in evaluating ultrasound images without professional expertise. To address this issue, image-based automatic bladder volume estimation methods have been introduced, but most conventional methods require high-complexity computing resources that are not available in point-of-care (POC) settings. Therefore, in this study, a deep learning-based bladder volume measurement system was developed for POC settings using a lightweight convolutional neural network (CNN)-based segmentation model, which was optimized on a low-resource system-on-chip (SoC) to detect and segment the bladder region in ultrasound images in real time. The proposed model achieved high accuracy and robustness and can be executed on the low-resource SoC at 7.93 frames per second, which is 13.44 times faster than the frame rate of a conventional network with negligible accuracy drawbacks (0.004 of the Dice coefficient). The feasibility of the developed lightweight deep learning network was demonstrated using tissue-mimicking phantoms.
- 26 April 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (5) , 525
Open AccessA Lightweight Deep Learning Network on a System-on-Chip for Wearable Ultrasound Bladder Volume Measurement Systems: Preliminary Study
Bladder volume assessments are crucial for managing urinary disorders. Ultrasound imaging (US) is a preferred noninvasive, cost-effective imaging modality for bladder observation and volume measurements. However, the high operator dependency of US is a major challenge due to the difficulty in evaluating ultrasound images without professional expertise. To address this issue, image-based automatic bladder volume estimation methods have been introduced, but most conventional methods require high-complexity computing resources that are not available in point-of-care (POC) settings. Therefore, in this study, a deep learning-based bladder volume measurement system was developed for POC settings using a lightweight convolutional neural network (CNN)-based segmentation model, which was optimized on a low-resource system-on-chip (SoC) to detect and segment the bladder region in ultrasound images in real time. The proposed model achieved high accuracy and robustness and can be executed on the low-resource SoC at 7.93 frames per second, which is 13.44 times faster than the frame rate of a conventional network with negligible accuracy drawbacks (0.004 of the Dice coefficient). The feasibility of the developed lightweight deep learning network was demonstrated using tissue-mimicking phantoms.
- Open Access
Air-Coupled Ultrasound Sealing Integrity Inspection Using Leaky Lamb Waves in a Simplified Model of a Lithium-Ion Pouch Battery: Feasibility Study
Inspecting the sealing integrity of lead tabs is an important means of ensuring the reliability and safety of pouch-type lithium-ion (Li-ion) batteries with a thin multi-layered aluminum (Al) laminated film. This paper presents a new air-coupled ultrasonic non-destructive testing (NDT) inspection method based on leaky Lamb wave transmission; and reception for evaluating the sealing integrity between the lead tab and the Al pouch film. The proposed method uses the critical incidence angle between the air and the layer with the fastest Lamb wave velocity to maximize the signal-to-noise ratio in the through-transmission mode. To determine the critical incidence angle, phantom experiments with two test pieces (i.e., an Al tab and an Al tab sealed with an Al pouch film) are conducted. In addition, 2D scans are performed at various incidence angles for an inhouse pouch-type Li-ion battery with a 1-mm-wide foreign material inserted as a defect. At the critical incidence angle (i.e., 22°), the proposed air-coupled ultrasonic NDT method in through-transmission mode successfully identifies the shape and location of the defect through c-scan image reconstruction. These preliminary results indicate that the proposed air-coupled ultrasonic NDT method with leaky Lamb waves can be used to inspect the sealing integrity of Li-ion pouch batteries in dry test conditions.
Open AccessAir-Coupled Ultrasound Sealing Integrity Inspection Using Leaky Lamb Waves in a Simplified Model of a Lithium-Ion Pouch Battery: Feasibility Study
Inspecting the sealing integrity of lead tabs is an important means of ensuring the reliability and safety of pouch-type lithium-ion (Li-ion) batteries with a thin multi-layered aluminum (Al) laminated film. This paper presents a new air-coupled ultrasonic non-destructive testing (NDT) inspection method based on leaky Lamb wave transmission; and reception for evaluating the sealing integrity between the lead tab and the Al pouch film. The proposed method uses the critical incidence angle between the air and the layer with the fastest Lamb wave velocity to maximize the signal-to-noise ratio in the through-transmission mode. To determine the critical incidence angle, phantom experiments with two test pieces (i.e., an Al tab and an Al tab sealed with an Al pouch film) are conducted. In addition, 2D scans are performed at various incidence angles for an inhouse pouch-type Li-ion battery with a 1-mm-wide foreign material inserted as a defect. At the critical incidence angle (i.e., 22°), the proposed air-coupled ultrasonic NDT method in through-transmission mode successfully identifies the shape and location of the defect through c-scan image reconstruction. These preliminary results indicate that the proposed air-coupled ultrasonic NDT method with leaky Lamb waves can be used to inspect the sealing integrity of Li-ion pouch batteries in dry test conditions.
- 20 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (5) , 1300-1308
Real-Time Ultrasound Detection of Breast Microcalcifications Using Multifocus Twinkling Artifact Imaging
Detecting microcalcifications (MCs) in real time is important in the guidance of many breast biopsies. Due to its capability in visualizing biopsy needles without radiation hazards, ultrasound imaging is preferred over X-ray mammography, but it suffers from low sensitivity in detecting MCs. Here, we present a new nonionizing method based on real-time multifocus twinkling artifact (MF-TA) imaging for reliably detecting MCs. Our approach exploits time-varying TAs arising from acoustic random scattering on MCs with rough or irregular surfaces. To obtain the increased intensity of the TAs from MCs, in MF-TA, acoustic transmit parameters, such as the transmit frequency, the number of focuses and f-number, were optimized by investigating acoustical characteristics of MCs. A real-time MF-TA imaging sequence was developed and implemented on a programmable ultrasound research system, and it was controlled with a graphical user interface during real-time scanning. From an in-house 3D phantom and ex vivo breast specimen studies, the MF-TA method showed outstanding visibility and high-sensitivity detection for MCs regardless of their distribution or the background tissue. These results demonstrated that this nonionizing, noninvasive imaging technique has the potential to be one of effective image-guidance methods for breast biopsy procedures.
- 20 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 41 (5) , 1300-1308
Real-Time Ultrasound Detection of Breast Microcalcifications Using Multifocus Twinkling Artifact Imaging
Detecting microcalcifications (MCs) in real time is important in the guidance of many breast biopsies. Due to its capability in visualizing biopsy needles without radiation hazards, ultrasound imaging is preferred over X-ray mammography, but it suffers from low sensitivity in detecting MCs. Here, we present a new nonionizing method based on real-time multifocus twinkling artifact (MF-TA) imaging for reliably detecting MCs. Our approach exploits time-varying TAs arising from acoustic random scattering on MCs with rough or irregular surfaces. To obtain the increased intensity of the TAs from MCs, in MF-TA, acoustic transmit parameters, such as the transmit frequency, the number of focuses and f-number, were optimized by investigating acoustical characteristics of MCs. A real-time MF-TA imaging sequence was developed and implemented on a programmable ultrasound research system, and it was controlled with a graphical user interface during real-time scanning. From an in-house 3D phantom and ex vivo breast specimen studies, the MF-TA method showed outstanding visibility and high-sensitivity detection for MCs regardless of their distribution or the background tissue. These results demonstrated that this nonionizing, noninvasive imaging technique has the potential to be one of effective image-guidance methods for breast biopsy procedures.
- Open Access
- 8 July 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (13) , 2752
Efficient Transmit Delay Calculation in Ultrasound Coherent Plane-Wave Compound Imaging for Curved Array Transducers
The recently introduced plane-wave compounding method based on multiple plane-wave excitation has enabled several new applications due to its high frame rate (>1000 Hz). In this paper, a new efficient transmit delay calculation method in plane-wave compound imaging for a curved array transducer is presented. In the proposed method, the transmit delay is only calculated for a steering angle of 0° and is shifted along the element of the transducer to obtain other transmit delays for different steering angles. To evaluate the performance of the proposed method, the computational complexity was measured for various transmission conditions. For the number of elements and plane-wave excitations of 128 and 65, respectively, the number of operations was substantially decreased in the proposed method compared with the conventional method (256 vs. 8320). The benefits of the proposed method were demonstrated with phantom and in vivo experiments, where coherent plane-wave compounding with 65 excitations provided larger CR and CNR values compared to nine excitations (−22.5 dB and 2.7 vs. −11.3 dB and 1.9, respectively). These results indicate the proposed method can effectively reduce the computational complexity for plane-wave compound imaging in curved array transducers.
- 8 July 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (13) , 2752
Open AccessEfficient Transmit Delay Calculation in Ultrasound Coherent Plane-Wave Compound Imaging for Curved Array Transducers
The recently introduced plane-wave compounding method based on multiple plane-wave excitation has enabled several new applications due to its high frame rate (>1000 Hz). In this paper, a new efficient transmit delay calculation method in plane-wave compound imaging for a curved array transducer is presented. In the proposed method, the transmit delay is only calculated for a steering angle of 0° and is shifted along the element of the transducer to obtain other transmit delays for different steering angles. To evaluate the performance of the proposed method, the computational complexity was measured for various transmission conditions. For the number of elements and plane-wave excitations of 128 and 65, respectively, the number of operations was substantially decreased in the proposed method compared with the conventional method (256 vs. 8320). The benefits of the proposed method were demonstrated with phantom and in vivo experiments, where coherent plane-wave compounding with 65 excitations provided larger CR and CNR values compared to nine excitations (−22.5 dB and 2.7 vs. −11.3 dB and 1.9, respectively). These results indicate the proposed method can effectively reduce the computational complexity for plane-wave compound imaging in curved array transducers.
- Open Access
- 29 May 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (11) , 2202
Design and Implementation of a New Wireless Carotid Neckband Doppler System with Wearable Ultrasound Sensors: Preliminary Results
Noninvasive monitoring of blood flow in the carotid artery is important for evaluating not only cerebrovascular but also cardiovascular diseases. In this paper, a wireless neckband ultrasound Doppler system, in which two 2.5-MHz ultrasonic sensors are utilized for acquiring Doppler signals from both carotid arteries, is presented for continuously evaluating blood flow dynamics. In the developed wireless neckband Doppler system, the acquired Doppler signals are quantized by 14-bit analog-to-digital-converters running at 40 MHz, and pre-processing operations (i.e., demodulation and clutter filtering) are performed in an embedded field programmable gate array chip. Then, these data are transferred to an external smartphone (i.e., Galaxy S7, Samsung Electronics Co., Suwon, Korea) via Bluetooth 2.0. Post-processing (i.e., Fourier transform and image processing) is performed using an embedded application processor in the smartphone. The developed carotid neckband Doppler system was evaluated with phantom and in vivo studies. In a phantom study, the neckband Doppler system showed comparable results with a commercial ultrasound machine in terms of peak systolic velocity and resistive index, i.e., 131.49 ± 3.97 and 0.75 ± 0.02 vs. 131.89 ± 2.06 and 0.74 ± 0.02, respectively. In addition, in the in vivo study, the neckband Doppler system successfully demonstrated its capability to continuously evaluate hemodynamics in both common carotid arteries. These results indicate that the developed wireless neckband Doppler system can be used for continuous monitoring of blood flow dynamics in the common carotid arteries in point-of-care settings.
- 29 May 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (11) , 2202
Open AccessDesign and Implementation of a New Wireless Carotid Neckband Doppler System with Wearable Ultrasound Sensors: Preliminary Results
Noninvasive monitoring of blood flow in the carotid artery is important for evaluating not only cerebrovascular but also cardiovascular diseases. In this paper, a wireless neckband ultrasound Doppler system, in which two 2.5-MHz ultrasonic sensors are utilized for acquiring Doppler signals from both carotid arteries, is presented for continuously evaluating blood flow dynamics. In the developed wireless neckband Doppler system, the acquired Doppler signals are quantized by 14-bit analog-to-digital-converters running at 40 MHz, and pre-processing operations (i.e., demodulation and clutter filtering) are performed in an embedded field programmable gate array chip. Then, these data are transferred to an external smartphone (i.e., Galaxy S7, Samsung Electronics Co., Suwon, Korea) via Bluetooth 2.0. Post-processing (i.e., Fourier transform and image processing) is performed using an embedded application processor in the smartphone. The developed carotid neckband Doppler system was evaluated with phantom and in vivo studies. In a phantom study, the neckband Doppler system showed comparable results with a commercial ultrasound machine in terms of peak systolic velocity and resistive index, i.e., 131.49 ± 3.97 and 0.75 ± 0.02 vs. 131.89 ± 2.06 and 0.74 ± 0.02, respectively. In addition, in the in vivo study, the neckband Doppler system successfully demonstrated its capability to continuously evaluate hemodynamics in both common carotid arteries. These results indicate that the developed wireless neckband Doppler system can be used for continuous monitoring of blood flow dynamics in the common carotid arteries in point-of-care settings.