Azeddine Bouzbiba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Azeddine Bouzbiba has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Abbou
Mohammed V University in Rabat
6 shared publications - Yassine Taleb
EREEC Laboratory, Department of Electrical Engineering, Mohammadia School of Engineering, Mohammed V University in Rabat, Rabat 11000, Morocco
6 shared publications - Roa Lamrani
Advanced Systems Engineering Laboratory, National School of Applied Sciences (ENSA), Ibn Tofail University, Kenitra 14000, Morocco
1 shared publication
Latest Publications
- Open Access
- 6 May 2026
- Published by MDPI AG in Electricity
- Vol. 7 (2) , 42
Evaluation of Power Quality in Railway Systems: Challenge of Intermittency and Proposal of a Synchronized Aggregation Methodology for Reliable Compliance
This article highlights the intrinsic limitations of existing standards, such as EN 50160 and its associated measurement techniques, when applied to the assessment of power quality in high-speed railway traction power supply networks. These networks, characterized by intermittent and non-linear loads, generate disturbances (harmonics, voltage unbalance) that are not always detected or correctly quantified by standardized aggregation methods, leading to an underestimation of the actual impacts and calling into question the credibility of compliance assessments. The study proposes a new evaluation methodology based on synchronizing measurements with train traffic and grouping data by events rather than by fixed aggregation periods. This approach enables a more accurate characterization of negative-sequence voltage unbalance, providing a reliable estimation of both the magnitude and duration of disturbances. Experimental observations from multiple journeys and aggregation scenarios provide quantitative evidence supporting the relevance of the proposed improvements, which will contribute to updating and implementing standards better adapted to the specific characteristics of intermittent networks such as railway traffic, thereby ensuring a reliable, credible, and reproducible power quality assessment.
- 6 May 2026
- Published by MDPI AG in Electricity
- Vol. 7 (2) , 42
Open AccessEvaluation of Power Quality in Railway Systems: Challenge of Intermittency and Proposal of a Synchronized Aggregation Methodology for Reliable Compliance
This article highlights the intrinsic limitations of existing standards, such as EN 50160 and its associated measurement techniques, when applied to the assessment of power quality in high-speed railway traction power supply networks. These networks, characterized by intermittent and non-linear loads, generate disturbances (harmonics, voltage unbalance) that are not always detected or correctly quantified by standardized aggregation methods, leading to an underestimation of the actual impacts and calling into question the credibility of compliance assessments. The study proposes a new evaluation methodology based on synchronizing measurements with train traffic and grouping data by events rather than by fixed aggregation periods. This approach enables a more accurate characterization of negative-sequence voltage unbalance, providing a reliable estimation of both the magnitude and duration of disturbances. Experimental observations from multiple journeys and aggregation scenarios provide quantitative evidence supporting the relevance of the proposed improvements, which will contribute to updating and implementing standards better adapted to the specific characteristics of intermittent networks such as railway traffic, thereby ensuring a reliable, credible, and reproducible power quality assessment.
- Open Access
- 30 June 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 330, 03003
Analysis of the electrical power generated by a 2 Mwp photovoltaic plant connected to the MV distribution network: Focus on the power factor
This article presents a case study on analyzing active and reactive power injected by a 2 MWp photovoltaic (PV) power plant to the MV distribution network. Data were collected over 18 hours, from April 21, 2022 at 15:13 pm to April 22, 2022 at 9:50 am, using a qualimeter based on the NIDAQ 6008 card. The main objective of this study was to evaluate variations in power quality over a one-second measurement period, with particular emphasis on the impact of sunrise and sunset on PV plant output. The electrical parameters measured included active, reactive, and as well as power factor. The analysis revealed significant fluctuations in active and reactive power throughout the measurement period, with variations corresponding to weather conditions and grid load. The results were contextualized using a scientific literature review, which provided an overview of previous research on power quality in grid-connected PV systems. This study provides valuable insights for better management of photovoltaic solar power in MV distribution networks, highlighting the importance of taking diurnal variations into account in solar power generation.
- 30 June 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 330, 03003
Open AccessAnalysis of the electrical power generated by a 2 Mwp photovoltaic plant connected to the MV distribution network: Focus on the power factor
This article presents a case study on analyzing active and reactive power injected by a 2 MWp photovoltaic (PV) power plant to the MV distribution network. Data were collected over 18 hours, from April 21, 2022 at 15:13 pm to April 22, 2022 at 9:50 am, using a qualimeter based on the NIDAQ 6008 card. The main objective of this study was to evaluate variations in power quality over a one-second measurement period, with particular emphasis on the impact of sunrise and sunset on PV plant output. The electrical parameters measured included active, reactive, and as well as power factor. The analysis revealed significant fluctuations in active and reactive power throughout the measurement period, with variations corresponding to weather conditions and grid load. The results were contextualized using a scientific literature review, which provided an overview of previous research on power quality in grid-connected PV systems. This study provides valuable insights for better management of photovoltaic solar power in MV distribution networks, highlighting the importance of taking diurnal variations into account in solar power generation.
- Open Access
- 17 February 2025
- Published by MDPI AG in Preprints.org
Evaluation of the Energy Quality of a 2 MWp Photovoltaic Power Plant Integrated into the Distribution Network: Revision of the EN50160 Standard on Total Harmonic Distortion and Voltage Variations
With the increasing integration of renewable energy sources into the distribution network and the growing complexity of modern power grids, electricity quality has become a major concern. This paper analyzes the performance of a 2 MWp photovoltaic power plant connected to a 22 kV distribution grid, focusing on Total Harmonic Distortion (THD) and voltage unbalances, including homopolar and inverse components. Measurements taken during critical periods, particularly at sunrise and sunset, highlight the need to review energy quality parameters over time intervals shorter than ten minutes to better detect and understand significant deviations, especially in grids with high renewable energy integration. This study highlights the shortcomings of existing standards and proposes revisions to better ad-dress the challenges posed by renewable energy integration. The recommendations aim to improve electricity quality assessment and ensure optimal compatibility with contemporary and future technologies.
- 17 February 2025
- Published by MDPI AG in Preprints.org
Open AccessEvaluation of the Energy Quality of a 2 MWp Photovoltaic Power Plant Integrated into the Distribution Network: Revision of the EN50160 Standard on Total Harmonic Distortion and Voltage Variations
With the increasing integration of renewable energy sources into the distribution network and the growing complexity of modern power grids, electricity quality has become a major concern. This paper analyzes the performance of a 2 MWp photovoltaic power plant connected to a 22 kV distribution grid, focusing on Total Harmonic Distortion (THD) and voltage unbalances, including homopolar and inverse components. Measurements taken during critical periods, particularly at sunrise and sunset, highlight the need to review energy quality parameters over time intervals shorter than ten minutes to better detect and understand significant deviations, especially in grids with high renewable energy integration. This study highlights the shortcomings of existing standards and proposes revisions to better ad-dress the challenges posed by renewable energy integration. The recommendations aim to improve electricity quality assessment and ensure optimal compatibility with contemporary and future technologies.
- 29 April 2023
- Published by Springer Nature
- p. 761-772
Realization of an Electrical Power Quality Analyzer Based on NIDAQ6009 Board
- 29 April 2023
- Published by Springer Nature
- p. 761-772
Realization of an Electrical Power Quality Analyzer Based on NIDAQ6009 Board
- 6 May 2022
- Published by Springer Nature
- p. 706-717
Design a Power Quality Analyzer Using an ARDUINO Card and Display Signals in the LABVIEW Environment
- 6 May 2022
- Published by Springer Nature
- p. 706-717
Design a Power Quality Analyzer Using an ARDUINO Card and Display Signals in the LABVIEW Environment