LWLingyun Wang

Lingyun Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lingyun Wang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Freqformer: Frequency-Domain Transformer for 3-D Reconstruction and Quantification of Human Retinal Vasculature

    by Lingyun Wang, Bingjie Wang, Jay Chhablani, Jose Alain Sahel, Shaohua Pi

    Objective: To achieve accurate 3-D reconstruction and quantitative analysis of human retinal vasculature from a single optical coherence tomography angiography (OCTA) scan. Methods: We introduce Freqformer, a novel Transformer-based model featuring a dual-branch architecture that integrates a Transformer layer for capturing global spatial context with a complex-valued frequency-domain module designed for adaptive frequency enhancement. Freqformer was trained using single depth-plane OCTA images, utilizing volumetrically merged OCTA as ground truth. Performance was evaluated quantitatively through 2-D and 3-D image metrics. 2-D networks and their 3-D counterparts were compared to assess the differences between enhancing volume slice by slice and enhancing it by 3-D patches. Furthermore, 3-D quantitative vascular metrics were conducted to quantify human retinal vasculature. Results: Freqformer substantially outperformed existing convolutional neural networks and Transformer-based methods, achieving superior image metrics. Importantly, the enhanced OCTA volumes show strong correlation with the merged volumes on vascular segment count, density, length, and flow index, further underscoring its reliability for quantitative vascular analysis. 3-D counterparts did not yield additional gains in image metrics or downstream 3-D vascular quantification but incurred nearly an order-of-magnitude longer inference time, supporting our 2-D slice-wise enhancement strategy. Additionally, Freqformer showed excellent generalization capability on larger field-of-view scans, surpassing the quality of conventional volumetric merging methods. Conclusion: Freqformer reliably generates high-definition 3-D retinal microvasculature from single-scan OCTA, enabling precise vascular quantification comparable to standard volumetric merging methods. Significance: Freqformer has promising clinical applications in early detection, detailed microvasculature analysis, and monitoring of retinal vascular diseases through advanced 3-D quantitative assessments.


  • Tartrazine-enhanced visible-light OCT for deep-tissue imaging

    by Jiaxuan Kong, Lingyun Wang, Shaohua Pi

    Visible-light optical coherence tomography (vis-OCT) provides ultrahigh axial resolution and intrinsic spectroscopic contrast, but its performance in deep tissues is fundamentally limited by strong scattering and absorption at short wavelengths. Here, we report the use of tartrazine—an FDA-approved, water-soluble food dye—as a rapid, biocompatible contrast enhancer to improve vis-OCT penetration and structural visibility across multiple tissue types. We systematically evaluated tartrazine-assisted imaging in postmortem chicken muscle, optic nerve, and brain cortex, as well as in vivo at the ocular limbus and mouse ear. Topical or surface immersion with low-concentration tartrazine solutions significantly improved the vis-OCT signal in deep tissue with increased signal-to-noise ratio, extended penetration, and enhanced structure contrast. These results establish Tartrazine as an inexpensive, safe, and effective optical clearing and contrast-enhancing agent for vis-OCT, enabling deeper and higher-fidelity imaging of biological tissues both ex vivo and in vivo .


  • BreakNet: discontinuity-resilient multi-scale transformer segmentation of retinal layers

    by Razieh Ganjee, Bingjie Wang, Lingyun Wang, Chengcheng Zhao, José-Alain Sahel, Shaohua Pi

    Visible light optical coherence tomography (vis-OCT) is gaining traction for retinal imaging due to its high resolution and functional capabilities. However, the significant absorption of hemoglobin in the visible light range leads to pronounced shadow artifacts from retinal blood vessels, posing challenges for accurate layer segmentation. In this study, we present BreakNet, a multi-scale Transformer-based segmentation model designed to address boundary discontinuities caused by these shadow artifacts. BreakNet utilizes hierarchical Transformer and convolutional blocks to extract multi-scale global and local feature maps, capturing essential contextual, textural, and edge characteristics. The model incorporates decoder blocks that expand pathways to enhance the extraction of fine details and semantic information, ensuring precise segmentation. Evaluated on rodent retinal images acquired with prototype vis-OCT, BreakNet demonstrated superior performance over state-of-the-art segmentation models, such as TCCT-BP and U-Net, even when faced with limited-quality ground truth data. Our findings indicate that BreakNet has the potential to significantly improve retinal quantification and analysis.


  • Fully automated OCT-based tissue screening system

    by Shaohua Pi, Razieh Ganjee, Lingyun Wang, Riley K. Arbuckle, Chengcheng Zhao, Jose A Sahel, Bingjie Wang, Yuanyuan Chen

    This study introduces an innovative optical coherence tomography (OCT) imaging system dedicated to high-throughput screening applications using ex vivo tissue culture. Leveraging OCT’s non-invasive, high-resolution capabilities, the system is equipped with a custom-designed motorized platform and tissue detection ability for automated, successive imaging across samples. Transformer-based deep-learning segmentation algorithms further ensure robust, consistent, and efficient readouts meeting the standards for screening assays. Validated using retinal explant cultures from a mouse model of retinal degeneration, the system provides robust, rapid, reliable, unbiased, and comprehensive readouts of tissue response to treatments. This fully automated OCT-based system marks a significant advancement in tissue screening, promising to transform drug discovery, as well as other relevant research fields.


  • Sub2Full: split spectrum to boost optical coherence tomography despeckling without clean data

    by Lingyun Wang, Jose A Sahel, Shaohua Pi

    Optical coherence tomography (OCT) suffers from speckle noise, causing the deterioration of image quality, especially in high-resolution modalities such as visible light OCT (vis-OCT). Here, we proposed an innovative self-supervised strategy called Sub2Full (S2F) for OCT despeckling without clean data. This approach works by acquiring two repeated B-scans, splitting the spectrum of the first repeat as a low-resolution input, and utilizing the full spectrum of the second repeat as the high-resolution target. The proposed method was validated on vis-OCT retinal images visualizing sublaminar structures in the outer retina and demonstrated superior performance over state-of-the-art Noise2Noise (N2N) and Noise2Void (N2V) schemes.


  • Axial super-resolution optical coherence tomography via complex-valued network

    by Lingyun Wang, Si Chen, Linbo Liu, Xue Yin, Guohua Shi, Jianhua Mo

    Optical coherence tomography (OCT) is a fast and non-invasive optical interferometric imaging technique that can provide high-resolution cross-sectional images of biological tissues. OCT’s key strength is its depth resolving capability which remains invariant along the imaging depth and is determined by the axial resolution. The axial resolution is inversely proportional to the bandwidth of the OCT light source. Thus, the use of broadband light sources can effectively improve the axial resolution and however leads to an increased cost. In recent years, real-valued deep learning technique has been introduced to obtain super-resolution optical imaging. In this study, we proposed a complex-valued super-resolution network (CVSR-Net) to achieve an axial super-resolution for OCT by fully utilizing the amplitude and phase of OCT signal. The method was evaluated on three OCT datasets. The results show that the CVSR-Net outperforms its real-valued counterpart with a better depth resolving capability. Furthermore, comparisons were made between our network, six prevailing real-valued networks and their complex-valued counterparts. The results demonstrate that the complex-valued network exhibited a better super-resolution performance than its real-valued counterpart and our proposed CVSR-Net achieved the best performance. In addition, the CVSR-Net was tested on out-of-distribution domain datasets and its super-resolution performance was well maintained as compared to that on source domain datasets, indicating a good generalization capability.


  • Optical coherence tomography for in vivo longitudinal monitoring of artificial dermal scaffold

    by Ziye Chen, Qiong Cheng, Lingyun Wang, Yunfeng Mo, Ke Li, Jianhua Mo

    Objectives: Artificial dermal scaffold (ADS) has undergone rapid development and been increasingly used for treating skin wound in clinics due to its good biocompatibility, controllable degradation, and low risk of disease infection. To obtain good treatment efficacy, ADS needs to be monitored longitudinally during the treatment process. For example, scaffold‐tissue fit, cell in‐growth, vascular regeneration, and scaffold degradation are the key properties to be inspected. However, to date, there are no effective, real‐time, and noninvasive techniques to meet the requirement of the scaffold monitoring above.Materials and Methods: In this study, we propose to use optical coherence tomography (OCT) to monitor ADS in vivo through three‐dimensional imaging. A swept source OCT system with a handheld probe was developed for in vivo skin imaging. Moreover, a cell in‐growth, vascular regeneration, and scaffold degradation rate (IRDR) was defined with the volume reduction rate of the scaffold's collagen sponge layer. To measure the IRDR, a semiautomatic image segmentation algorithm was designed based on U‐Net to segment the collagen sponge layer of the scaffold from OCT images.Results: The results show that the scaffold‐tissue fit can be clearly visualized under OCT imaging. The IRDR can be computed based on the volume of the segmented collagen sponge layer. It is observed that the IRDR appeared to a linear function of the time and in addition, the IRDR varied among different skin parts.Conclusion: Overall, it can be concluded that OCT has a good potential to monitor ADS in vivo. This can help guide the clinicians to control the treatment with ADS to improve the therapy.


  • Compressive‐sensing swept‐source optical coherence tomography angiography with reduced noise

    by Lingyun Wang, Ziye Chen, Zhanyu Zhu, Xiaojun Yu, Jianhua Mo

    Optical coherence tomography angiography (OCTA), as a functional extension of optical coherence tomography (OCT), has exhibited a great potential to aid in clinical diagnostics. Currently, OCTA still suffers from motion artifact and noise. Therefore, in this article, we propose to implement compressive sensing (CS) on B‐scans to reduce motion artifact by increasing B‐scan rate. Meanwhile, a noise reduction filter is specially designed by combining CS, Gaussian filter and median filter. Specially, CS filtering is realized by averaging multiple CS repetitions on en‐face OCTA images with varied sampling functions. The method is evaluated on in vivo OCTA images of human skin. The results show that vasculature structures can be reconstructed well through CS on B‐scans with a sampling rate of 70%. Moreover, the noise can be significantly eliminated by the developed filter. This implies that our method has a good potential to expedite OCTA imaging and improve the image quality.