DZDong Zhang

Dong Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dong Zhang has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Interfacial regulation of droplet impact energy partitioning on VO2-SiO2 superhydrophobic composite coatings

    by Tianzhen Zhang, Dong Zhang, Yuqi Zhang, Liqiang Zhang, Xing Ding, Longkai Li

  • Open Access

    Effects of operating strategies on capacity configuration and operational performance of a grid-connected park-level multi-energy complementary system during the transition to a new power system

    by Baohong Jin, Xu Hong, Xilian Han, Yimeng Hu, Dong Zhang, Jinping Li

    Operating strategy strongly influences both capacity sizing and dispatch in grid-connected park-level multi-energy complementary systems (PMECSs). Conventional cost-oriented strategies, however, do not fully capture the effect of increasing renewable energy penetration ratio (REPR) on the supply side of the new power system. This study proposes a carbon-penalty-based operating strategy and develops a bi-level multi-objective stochastic optimization model that explicitly considers supply-side REPR. A Copula model and a first-order autoregressive model are used to characterize the spatial and temporal correlations among renewable generation, load, and ambient conditions. Representative scenarios are then generated through Latin hypercube sampling and Wasserstein-distance-based reduction. Using these scenarios, the supply-side REPR is varied from 0% to 100% at 20% intervals to optimize system configuration and evaluate operational performance, and the results are compared with those of a conventional strategy. The proposed strategy increases the capacities of the ground-source heat pump and photovoltaic/thermal unit while reducing the capacity of the combined heat and power unit. At the same REPR, the optimized system reduces total cost, CO2 emissions, and primary energy consumption by up to 3.7%, 21.13%, and 30.42%, respectively, relative to the conventional strategy. Multi-scenario simulations further confirm the superiority and robustness of the proposed strategy. These results demonstrate that incorporating carbon penalties can better unlock the economic and environmental benefits of higher supply-side REPR in PMECSs.

  • Open Access

    Coordinated Optimal Dispatch of Electricity–Cooling–Storage Multi-Energy Systems in Commercial Building Clusters

    by Zhenlan Dou, Huawei Huang, Chunyan Zhang, Jiaqi Li, Dong Zhang

    This study addresses the energy demand profiles of commercial buildings by developing an optimal dispatch strategy for a regional high-efficiency distributed energy system integrating electricity, cooling, and storage through source–load coordination. The spatiotemporal distribution characteristics of cooling, heating, and electrical loads are analyzed and an integrated energy system model is established, comprising gas internal combustion engine, a lithium bromide absorption chiller/heater, gas-fired boiler, centrifugal chillers, and an ice storage system. Taking into account seasonal electricity pricing policies and meteorological variations in Shanghai, a load grading system and a time-of-use (TOU) pricing response mechanism are constructed, leading to the development of operational strategy portfolios for different typical scenarios. A multi-objective optimization dispatch model is formulated with the dual aims of minimizing operating costs and maximizing energy efficiency. The results indicate that, compared to a fixed operational mode, the optimized strategy achieves average CO2 emission reduction rates of 16.4% in summer, 25.2% in non-summer periods, and 20.9% annually. Additionally, annual grid electricity purchases are reduced by 10.2%, with a static investment payback period of 11.37 years. This research provides an intelligent, practically applicable operational solution for distributed energy systems in commercial buildings, effectively overcoming the limitations of traditional approaches in terms of flexibility and economic performance.

  • Data-driven fouling prediction and health monitoring of plate heat exchangers based on accelerated fouling experiments and deep learning models

    by HuiTing Zhang, Gang Hou, GuangZhong Huang, JingWei Liu, MeiJiao Jiang, Han Jiang, Zhoujian An, Dong Zhang

  • Effect of waste heat recovery pathways on the thermo-economic performance of a solar-augmented CCES system: A mechanism study

    by Dong Zhang, Jingyi Jia, Xinyue Su, Yueyi Li, Qingdong Deng, Yong Ding, Zhoujian An

  • Open Access

    Effects of operating strategies on capacity configuration and operational performance of a grid-connected park-level multi-energy complementary system during the transition to a new power system

    by Baohong Jin, Xu Hong, Xilian Han, Yimeng Hu, Dong Zhang, Jinping Li

    Operating strategy strongly influences both capacity sizing and dispatch in grid-connected park-level multi-energy complementary systems (PMECSs). Conventional cost-oriented strategies, however, do not fully capture the effect of increasing renewable energy penetration ratio (REPR) on the supply side of the new power system. This study proposes a carbon-penalty-based operating strategy and develops a bi-level multi-objective stochastic optimization model that explicitly considers supply-side REPR. A Copula model and a first-order autoregressive model are used to characterize the spatial and temporal correlations among renewable generation, load, and ambient conditions. Representative scenarios are then generated through Latin hypercube sampling and Wasserstein-distance-based reduction. Using these scenarios, the supply-side REPR is varied from 0% to 100% at 20% intervals to optimize system configuration and evaluate operational performance, and the results are compared with those of a conventional strategy. The proposed strategy increases the capacities of the ground-source heat pump and photovoltaic/thermal unit while reducing the capacity of the combined heat and power unit. At the same REPR, the optimized system reduces total cost, CO2 emissions, and primary energy consumption by up to 3.7%, 21.13%, and 30.42%, respectively, relative to the conventional strategy. Multi-scenario simulations further confirm the superiority and robustness of the proposed strategy. These results demonstrate that incorporating carbon penalties can better unlock the economic and environmental benefits of higher supply-side REPR in PMECSs.

  • Open Access

    Optimization design and analysis of precooler for SCO2 Brayton cycle based on multi-objective genetic algorithm

    by Jian Fu, Hanyi Liu, Zhoujian An, Yong Ding, Xiaoze Du, Dong Zhang, Guochun Liu, Yan Wang

    The Supercritical carbon dioxide Brayton cycle (SCBC) is a promising technology for renewable thermal power generation, known for its compact layout and high thermodynamic efficiency. In the SCBC, the recuperator, heater, and precooler are typically realized using printed circuit heat exchangers (PCHEs). While most current research focuses on the recuperator and heater, research focusing on the precooler remains relatively limited. The impact of precooler design on cycle efficiency has not yet been fully explored. To address this research gap, the optimal design of the precooler in the SCBC is investigated through a multi-objective genetic algorithm in present study. The design procedure first examines the effects of individual boundary conditions and geometric parameters on precooler performance. Subsequently, a multi-objective optimization is performed using the Non-dominated Sorting Genetic Algorithm II (NSGA-II), with cycle thermal efficiency, entropy generation, and total cost are selected as the optimization objectives. Finally, based on a trade-off analysis of the Pareto frontier, the optimal design point is identified. The three objective values corresponding to the final design point are 0.53, 3.07×10-4, and 38.80, respectively. The findings provide a reference design point for the precooler in SCBC, established through a holistic consideration of cycle efficiency, irreversibility, and economic performance.

  • Effect of Vapor Pressure Difference on the Operating Characteristics of Pulsating Heat Pipe Using Non-Azeotropic Water/HFE-7100 Mixture

    by Zeyuan Zhao, Dong Zhang, Haixia Li, Qingdong Deng, Yong Ding, Zehao Li, Zhoujian An

    Pulsating heat pipes (PHPs), as highly efficient heat transfer devices, have been widely employed in thermal management systems in recent years. However, their unique structural characteristics often lead to stagnation, intermittent oscillation, and dry-out, particularly at low inclination angles. In this study, a three-dimensional closed-loop PHP charged with a non-azeotropic mixture of water and HFE-7100 was designed with the aim of broadening the operational range of PHPs. Comparative experiments were conducted between the non-azeotropic mixture PHP and single-fluid PHP charged with either water or HFE-7100 under identical operating conditions, in order to evaluate the enhancement of heat transfer performance. The enhancement mechanism of the non-azeotropic working fluid was analyzed in detail from the perspective of its thermophysical properties. The experimental results demonstrate that, under low inclination angles, the water charged PHP is more susceptible to dry-out. The thermal resistance of the HFE-7100 PHP is consistently higher than that of the mixture PHP. The non-azeotropic mixture effectively extends the stable operating range of the PHP. However, due to the significant difference in the saturated vapor pressures of the two working fluids, the water-charged PHP exhibits superior heat transfer performance at 50% filling ratio under inclination angles of 70° and 90°. Therefore, this study comprehensively analyzes the operating characteristics of the HFE-7100/water mixture PHP based on thermophysical properties in conjunction with temperature and pressure data. Finally, recommendations are provided for the selection of non-azeotropic immiscible working fluids.