Lihua Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lihua Li has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Xiaoqin Chen
Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin, P.R. China
8 shared publicationsXiaoyan Yang
Nankai University Optometry & Vision Science Institute
7 shared publicationsCui Yu
He Eye Specialist Hospital, Shenyang, P.R. China
4 shared publicationsMengdi Li
Nankai University Optometry & Vision Science Institute
4 shared publicationsMin Wu
Beijing Tongren Vision Care, Beijing Tongren Hospital, Capital Medical University, Beijing, P.R. China
4 shared publications- Yan Wang
School of Medicine, Nankai University
3 shared publications
Latest Publications
- Open Access
- 10 November 2026
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 14, 2001331
Association between daily near-vision duration and visual symptom burden among university staff: a cross-sectional study
Background: University staff routinely perform prolonged near-viewing tasks that may contribute to visual symptoms and work-related difficulties. We examined the associations of daily near-vision duration with Convergence Insufficiency Symptom Survey (CISS) score and of near-vision duration and CISS score with self-reported work impact. Methods: This cross-sectional survey included 255 university staff members. Daily near-vision duration was analyzed per 2 h/day. Linear regression estimated adjusted mean differences in continuous CISS score, and modified Poisson regression estimated prevalence ratios (PRs) for CISS score ≥21 and self-reported work impact. Models adjusted for age, sex, education, work type, and survey year. Results: The primary CISS models included 253 of 255 respondents. Among 228 respondents with an applicable work-impact response, the work-impact model included 226 complete cases. Mean CISS score was 22.7 (SD 10.9), 58.0% had a score ≥21, and 53.9% of respondents with applicable responses reported work impact. Each additional 2 h/day of near-vision duration was associated with a 1.79-point higher CISS score (95% CI 0.73–2.84) and a PR of 1.15 (95% CI 1.07–1.24) for CISS score ≥21. In the mutually adjusted work-impact model, the PRs were 1.03 (95% CI 0.95–1.12) per 2 h/day and 1.18 (95% CI 1.11–1.25) per 5 CISS points. Conclusion: Longer daily near-vision duration was associated with greater visual symptom burden, and higher CISS score was associated with self-reported work impact. Assessing visual symptoms alongside near-work duration may help occupational health services identify staff who could benefit from eye examination and workplace assessment.
- 10 November 2026
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 14, 2001331
Open AccessAssociation between daily near-vision duration and visual symptom burden among university staff: a cross-sectional study
Background: University staff routinely perform prolonged near-viewing tasks that may contribute to visual symptoms and work-related difficulties. We examined the associations of daily near-vision duration with Convergence Insufficiency Symptom Survey (CISS) score and of near-vision duration and CISS score with self-reported work impact. Methods: This cross-sectional survey included 255 university staff members. Daily near-vision duration was analyzed per 2 h/day. Linear regression estimated adjusted mean differences in continuous CISS score, and modified Poisson regression estimated prevalence ratios (PRs) for CISS score ≥21 and self-reported work impact. Models adjusted for age, sex, education, work type, and survey year. Results: The primary CISS models included 253 of 255 respondents. Among 228 respondents with an applicable work-impact response, the work-impact model included 226 complete cases. Mean CISS score was 22.7 (SD 10.9), 58.0% had a score ≥21, and 53.9% of respondents with applicable responses reported work impact. Each additional 2 h/day of near-vision duration was associated with a 1.79-point higher CISS score (95% CI 0.73–2.84) and a PR of 1.15 (95% CI 1.07–1.24) for CISS score ≥21. In the mutually adjusted work-impact model, the PRs were 1.03 (95% CI 0.95–1.12) per 2 h/day and 1.18 (95% CI 1.11–1.25) per 5 CISS points. Conclusion: Longer daily near-vision duration was associated with greater visual symptom burden, and higher CISS score was associated with self-reported work impact. Assessing visual symptoms alongside near-work duration may help occupational health services identify staff who could benefit from eye examination and workplace assessment.
- Open Access
- 30 October 2026
- Published by Springer Nature in BMC Ophthalmology
Three-year results of cylindrical annular refractive elements (CARE) spectacle lenses in slowing myopia progression
Purpose: To evaluate the 3-year efficacy of spectacle lenses incorporating cylindrical annular refractive elements (CARE and CARE S) in slowing myopia progression and axial elongation in children, and to assess whether treatment effects were sustained over time. Methods: 240 Chinese children aged 6–13 years with myopia of -0.75 to -5.00 D were enrolled in a multicentre, prospective, parallel-group, double-masked, randomized clinical trial and randomly assigned to wear single-vision (SV), CARE, or CARE S spectacle lenses. Cycloplegic spherical equivalent refraction (SE) and axial length (AL) were measured at 6-month intervals. After completion of the 2-year trial, participants were invited to continue for an additional year. At 30 months, children in the SV group were switched to CARE lenses, and hence Year 3 SV progression was estimated using linear mixed-effects models derived from observed data over the first 2 years. Three-year outcomes were adjusted for age, sex, study site, baseline refraction, and compliance. Results: A total of 186 participants (78%) completed the 3-year follow-up. Over 3 years, adjusted mean SE progression was − 1.69 D (95% CI, -1.85 to -1.53) in the SV group, compared with − 1.07 D (95% CI, -1.23 to -0.91) in the CARE group and − 1.24 D (CI, -1.40 to -1.08) in the CARE S group. Adjusted mean AL elongation was 0.85 mm (CI, 0.78 to 0.92) with SV lenses, 0.57 mm (CI, 0.50 to 0.64) with CARE lenses, and 0.67 mm (CI, 0.60 to 0.73) with CARE S lenses. Relative to SV lenses, myopia progression was reduced by 0.62 D/0.28 mm, and 0.45 D/0.18 mm with CARE and CARE S lenses respectively. Efficacy accrued with time. Comparing year to year change, annual progression with SV declined with time whereas CARE and CARE S groups demonstrated similar year to year changes. Conclusions: CARE and CARE S spectacle lenses demonstrated sustained efficacy in slowing myopia progression and axial elongation over 3 years in Chinese children. Greater efficacy was observed with CARE lenses. Despite age-related slowing of progression in the control group, CARE and CARE S lenses demonstrated consistent slowing. The clinically meaningful differences in slowing of myopia with CARE-based spectacle lenses support their use as a safe and effective option for myopia management in children. Trial registration: ClinicalTrials.gov, NCT05288335. Registration Date: February 9, 2022.
- 30 October 2026
- Published by Springer Nature in BMC Ophthalmology
Open AccessThree-year results of cylindrical annular refractive elements (CARE) spectacle lenses in slowing myopia progression
Purpose: To evaluate the 3-year efficacy of spectacle lenses incorporating cylindrical annular refractive elements (CARE and CARE S) in slowing myopia progression and axial elongation in children, and to assess whether treatment effects were sustained over time. Methods: 240 Chinese children aged 6–13 years with myopia of -0.75 to -5.00 D were enrolled in a multicentre, prospective, parallel-group, double-masked, randomized clinical trial and randomly assigned to wear single-vision (SV), CARE, or CARE S spectacle lenses. Cycloplegic spherical equivalent refraction (SE) and axial length (AL) were measured at 6-month intervals. After completion of the 2-year trial, participants were invited to continue for an additional year. At 30 months, children in the SV group were switched to CARE lenses, and hence Year 3 SV progression was estimated using linear mixed-effects models derived from observed data over the first 2 years. Three-year outcomes were adjusted for age, sex, study site, baseline refraction, and compliance. Results: A total of 186 participants (78%) completed the 3-year follow-up. Over 3 years, adjusted mean SE progression was − 1.69 D (95% CI, -1.85 to -1.53) in the SV group, compared with − 1.07 D (95% CI, -1.23 to -0.91) in the CARE group and − 1.24 D (CI, -1.40 to -1.08) in the CARE S group. Adjusted mean AL elongation was 0.85 mm (CI, 0.78 to 0.92) with SV lenses, 0.57 mm (CI, 0.50 to 0.64) with CARE lenses, and 0.67 mm (CI, 0.60 to 0.73) with CARE S lenses. Relative to SV lenses, myopia progression was reduced by 0.62 D/0.28 mm, and 0.45 D/0.18 mm with CARE and CARE S lenses respectively. Efficacy accrued with time. Comparing year to year change, annual progression with SV declined with time whereas CARE and CARE S groups demonstrated similar year to year changes. Conclusions: CARE and CARE S spectacle lenses demonstrated sustained efficacy in slowing myopia progression and axial elongation over 3 years in Chinese children. Greater efficacy was observed with CARE lenses. Despite age-related slowing of progression in the control group, CARE and CARE S lenses demonstrated consistent slowing. The clinically meaningful differences in slowing of myopia with CARE-based spectacle lenses support their use as a safe and effective option for myopia management in children. Trial registration: ClinicalTrials.gov, NCT05288335. Registration Date: February 9, 2022.
- Open Access
- 7 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Influence of design parameters on peripheral defocus after keratorefractive lenticule extraction
This study investigated changes in peripheral defocus before and after keratorefractive lenticule extraction (KLEx) and examined the associations between surgical design parameters and changes in peripheral defocus. This prospective longitudinal pre–post study included 78 patients with myopia who voluntarily chose to undergo KLEx from March to July 2023 at the Optometry Center of Tianjin Eye Hospital, Tianjin Medical University, Tianjin, China. Patients were divided into three groups according to spherical equivalent refractive error. Retinal relative defocus values (RDVs) within the 0°–53° field were measured using multispectral refractive topography before surgery and 3 months postoperatively. Paired-sample t-tests were used to compare preoperative and postoperative changes. Associations between surgical parameters and changes in RDVs were analyzed using Pearson’s correlation analysis. Three months after KLEx, myopic defocus increased at 10°–20°, the RDV at 20°–30° shifted from hyperopic to myopic defocus, and hyperopic defocus decreased at 30°–40° and 40°–53°. Central corneal cutting thickness was positively correlated with the change in RDV at 40°–53°. Percent tissue altered (PTA) was positively correlated with changes in RDVs at 30°–40° and 40–53°. Peripheral hyperopic defocus was reduced after KLEx. Central corneal cutting thickness appears to be an important factor associated with changes in peripheral defocus after KLEx. Greater corneal cutting thickness during surgery was associated with a greater postoperative reduction in peripheral hyperopic defocus.
- 7 July 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessInfluence of design parameters on peripheral defocus after keratorefractive lenticule extraction
This study investigated changes in peripheral defocus before and after keratorefractive lenticule extraction (KLEx) and examined the associations between surgical design parameters and changes in peripheral defocus. This prospective longitudinal pre–post study included 78 patients with myopia who voluntarily chose to undergo KLEx from March to July 2023 at the Optometry Center of Tianjin Eye Hospital, Tianjin Medical University, Tianjin, China. Patients were divided into three groups according to spherical equivalent refractive error. Retinal relative defocus values (RDVs) within the 0°–53° field were measured using multispectral refractive topography before surgery and 3 months postoperatively. Paired-sample t-tests were used to compare preoperative and postoperative changes. Associations between surgical parameters and changes in RDVs were analyzed using Pearson’s correlation analysis. Three months after KLEx, myopic defocus increased at 10°–20°, the RDV at 20°–30° shifted from hyperopic to myopic defocus, and hyperopic defocus decreased at 30°–40° and 40°–53°. Central corneal cutting thickness was positively correlated with the change in RDV at 40°–53°. Percent tissue altered (PTA) was positively correlated with changes in RDVs at 30°–40° and 40–53°. Peripheral hyperopic defocus was reduced after KLEx. Central corneal cutting thickness appears to be an important factor associated with changes in peripheral defocus after KLEx. Greater corneal cutting thickness during surgery was associated with a greater postoperative reduction in peripheral hyperopic defocus.
- Open Access
- 1 May 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (5) , 14
Effects of Myopia Control Spectacle Lenses on Peripheral Refraction and Contrast: Insights From Optical Modeling
To investigate potential optical cues underlying myopia control effects by examining how lenslet-array spectacle lenses influence peripheral refraction and image contrast. Three commercial lenslet-array spectacle lenses-MiyoSmart, Stellest, and diverse segmented defocus optics-were reconstructed in Zemax OpticStudio, together with a conventional single vision (SV) lens as a reference. The reconstructed lenses were coupled with the Navarro eye model to simulate spectacle wearing after experimental validation of the lens models. Optical performance was evaluated under both distance and near viewing conditions with accommodative lags of 0.50 diopters (D) and 1.00 D. Peripheral refraction components (M and J0) were derived from wavefront data. Point spread functions and modulation transfer functions were obtained, with the area under the modulation transfer function curve subsequently calculated. Simulated and experimental point spread functions showed strong agreement, confirming the reliability of the constructed spectacle models. Compared with the SV lens, the lenslet-array introduced M fluctuations (within ±0.25 D), manifesting as alternating positive and negative shifts relative to the SV baseline. Only the Stellest lens exhibited minimal myopic defocus over a limited eccentricity range, while the other designs failed to induce peripheral myopic defocus. In the horizontal meridian between 12.5° and 17.5° eccentricity, lenslet-array lenses exhibited reduced contrast at low spatial frequencies (≤6 cycles/degree) but increased cutoff frequencies and relatively enhanced contrast at higher frequencies (9-15 cycles/degree). Similar patterns were observed under near viewing with a 0.50 D accommodative lag. The myopia control efficacy of lenslet-array lenses may not be fully explained by the peripheral myopic defocus hypothesis. Instead, the observed reduction in low spatial frequency contrast, coupled with an elevated cutoff frequency that preserves high-frequency information, may provide the critical optical cues for slowing myopia progression. These hypothesized mechanisms warrant further clinical investigation.
- 1 May 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (5) , 14
Open AccessEffects of Myopia Control Spectacle Lenses on Peripheral Refraction and Contrast: Insights From Optical Modeling
To investigate potential optical cues underlying myopia control effects by examining how lenslet-array spectacle lenses influence peripheral refraction and image contrast. Three commercial lenslet-array spectacle lenses-MiyoSmart, Stellest, and diverse segmented defocus optics-were reconstructed in Zemax OpticStudio, together with a conventional single vision (SV) lens as a reference. The reconstructed lenses were coupled with the Navarro eye model to simulate spectacle wearing after experimental validation of the lens models. Optical performance was evaluated under both distance and near viewing conditions with accommodative lags of 0.50 diopters (D) and 1.00 D. Peripheral refraction components (M and J0) were derived from wavefront data. Point spread functions and modulation transfer functions were obtained, with the area under the modulation transfer function curve subsequently calculated. Simulated and experimental point spread functions showed strong agreement, confirming the reliability of the constructed spectacle models. Compared with the SV lens, the lenslet-array introduced M fluctuations (within ±0.25 D), manifesting as alternating positive and negative shifts relative to the SV baseline. Only the Stellest lens exhibited minimal myopic defocus over a limited eccentricity range, while the other designs failed to induce peripheral myopic defocus. In the horizontal meridian between 12.5° and 17.5° eccentricity, lenslet-array lenses exhibited reduced contrast at low spatial frequencies (≤6 cycles/degree) but increased cutoff frequencies and relatively enhanced contrast at higher frequencies (9-15 cycles/degree). Similar patterns were observed under near viewing with a 0.50 D accommodative lag. The myopia control efficacy of lenslet-array lenses may not be fully explained by the peripheral myopic defocus hypothesis. Instead, the observed reduction in low spatial frequency contrast, coupled with an elevated cutoff frequency that preserves high-frequency information, may provide the critical optical cues for slowing myopia progression. These hypothesized mechanisms warrant further clinical investigation.
- 18 December 2025
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 363 (2)
Dynamic event-triggered formation control of linear multi-agent systems with multiplicative noises
- 18 December 2025
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 363 (2)
Dynamic event-triggered formation control of linear multi-agent systems with multiplicative noises
- Open Access
- 9 October 2025
- Published by Springer Nature in BMC Public Health
- Vol. 25 (1) , 1-10
Health-related quality of life and its associated factors among high school students with myopia in China
To evaluate the health-related quality of life (HRQoL) of Chinese high school students with myopia and to investigate its potential associate factors. This cross-sectional study was conducted in seven high schools across three representative regions in China. Students were invited to participate in an eye examination and complete an online survey. The HRQoL was measured by using the Child Health Utility Nine-Dimension (CHU-9D) and 25-items National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25). Sociodemographic characteristics and vision-related characteristics were also collected. Descriptive statistics were performed on respondents’ characteristics and one-way analysis of variance was used to compare HRQoL among subgroups. Multivariable linear regression analyses were performed to identify contributing factors to HRQoL. A total of 2,198 students with myopia (53.1% male, age was 16.7 ± 0.8 years) were included in this study. The utility value of CHU-9D was 0.851 ± 0.160 (mean ± SD), the score of NEI-VFQ-25 was 91.112 ± 9.619. Higher NEI-VFQ-25 scores correspond with higher CHU-9D utility values. Regression analyses showed that the CHU-9D utility values were higher in younger students, males, those who adopted normal sitting position, those who spent more than 10 h outdoor-activities per week, and those who wore frame glasses. The NEI-VFQ-25 scores were higher in older students, females, those who adopted normal sitting position, and those who did not wear glasses. Myopia has a non-negligible impact on the HRQoL among Chinese high school students. Age, sex, sitting posture, time of outdoor-activities, and glasses type were deemed as the associated factors of HRQoL.
- 9 October 2025
- Published by Springer Nature in BMC Public Health
- Vol. 25 (1) , 1-10
Open AccessHealth-related quality of life and its associated factors among high school students with myopia in China
To evaluate the health-related quality of life (HRQoL) of Chinese high school students with myopia and to investigate its potential associate factors. This cross-sectional study was conducted in seven high schools across three representative regions in China. Students were invited to participate in an eye examination and complete an online survey. The HRQoL was measured by using the Child Health Utility Nine-Dimension (CHU-9D) and 25-items National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25). Sociodemographic characteristics and vision-related characteristics were also collected. Descriptive statistics were performed on respondents’ characteristics and one-way analysis of variance was used to compare HRQoL among subgroups. Multivariable linear regression analyses were performed to identify contributing factors to HRQoL. A total of 2,198 students with myopia (53.1% male, age was 16.7 ± 0.8 years) were included in this study. The utility value of CHU-9D was 0.851 ± 0.160 (mean ± SD), the score of NEI-VFQ-25 was 91.112 ± 9.619. Higher NEI-VFQ-25 scores correspond with higher CHU-9D utility values. Regression analyses showed that the CHU-9D utility values were higher in younger students, males, those who adopted normal sitting position, those who spent more than 10 h outdoor-activities per week, and those who wore frame glasses. The NEI-VFQ-25 scores were higher in older students, females, those who adopted normal sitting position, and those who did not wear glasses. Myopia has a non-negligible impact on the HRQoL among Chinese high school students. Age, sex, sitting posture, time of outdoor-activities, and glasses type were deemed as the associated factors of HRQoL.
- Open Access
- 15 July 2025
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 279, 11-20
Axial Growth and Meridian Modulation of Cornea Power in Children Wearing Orthokeratology Lenses of Different Back Optic Zone Diameters
- 15 July 2025
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 279, 11-20
Open AccessAxial Growth and Meridian Modulation of Cornea Power in Children Wearing Orthokeratology Lenses of Different Back Optic Zone Diameters
- Open Access
- 13 June 2025
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 278, 203-211
Efficacy of Cylindrical Annular Refractive Elements (CARE) Spectacle Lenses in Slowing Myopia Progression Over 2 Years
- 13 June 2025
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 278, 203-211
Open AccessEfficacy of Cylindrical Annular Refractive Elements (CARE) Spectacle Lenses in Slowing Myopia Progression Over 2 Years
- Open Access
- 28 April 2025
- Published by Elsevier in Ophthalmology
- Vol. 132 (9) , 972-979
Myopia Control Efficacy of Asymmetric Multipoint Defocus Technique Spectacle Lenses
- 28 April 2025
- Published by Elsevier in Ophthalmology
- Vol. 132 (9) , 972-979
Open AccessMyopia Control Efficacy of Asymmetric Multipoint Defocus Technique Spectacle Lenses
- 7 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1344-1358
Experimental and modeling analysis of lenses with concentric cylindrical annular refractive elements: impact on peripheral imaging
The mechanism by which myopia-managing spectacle lenses slow myopia progression remains controversial. Understanding the changes these lenses introduce to peripheral imaging properties helps shed light on this controversial issue. Given the difficulty of directly measuring these changes in clinical settings, this study combined experimental and modeling approaches to evaluate changes in images at the retina induced by myopia-managing lenses. Optical characteristics that may related to the efficacy of the lenses with concentric cylindrical annular refractive elements (CARE) in myopia control were investigated. Three lenses were evaluated: MyoCare (MC), MyoCare S (MCS), and a single vision (SV) lens with a custom-built physical eye model and optical simulations for the analysis. The simulated PSFs are consistent with the measured ones. PSF analysis showed that MC and MCS lenses produce discrete curves, resulting in remarkable distortion in the simulated retina images, especially for large eccentricities. Whether they increase or decrease contrast depends on the spatial frequencies and eccentricities. These lenses also increase retinal light intensity at different eccentricities. The positive power of the CARE structure introduces myopic defocus of less than 0.25 D at only a limited range of eccentricities. The proposed approaches present relatively straightforward techniques for evaluating the optical performance of myopia-managing spectacle lenses.
- 7 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1344-1358
Experimental and modeling analysis of lenses with concentric cylindrical annular refractive elements: impact on peripheral imaging
The mechanism by which myopia-managing spectacle lenses slow myopia progression remains controversial. Understanding the changes these lenses introduce to peripheral imaging properties helps shed light on this controversial issue. Given the difficulty of directly measuring these changes in clinical settings, this study combined experimental and modeling approaches to evaluate changes in images at the retina induced by myopia-managing lenses. Optical characteristics that may related to the efficacy of the lenses with concentric cylindrical annular refractive elements (CARE) in myopia control were investigated. Three lenses were evaluated: MyoCare (MC), MyoCare S (MCS), and a single vision (SV) lens with a custom-built physical eye model and optical simulations for the analysis. The simulated PSFs are consistent with the measured ones. PSF analysis showed that MC and MCS lenses produce discrete curves, resulting in remarkable distortion in the simulated retina images, especially for large eccentricities. Whether they increase or decrease contrast depends on the spatial frequencies and eccentricities. These lenses also increase retinal light intensity at different eccentricities. The positive power of the CARE structure introduces myopic defocus of less than 0.25 D at only a limited range of eccentricities. The proposed approaches present relatively straightforward techniques for evaluating the optical performance of myopia-managing spectacle lenses.