Magdalena Góra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Magdalena Góra has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro J. Müller
University of the Basque Country UPV/EHU Paseo Manuel Lardizabal 3
3 shared publications - Dario Cavallo
University of Genova
3 shared publications Davide Tranchida
3 shared publicationsAndreas Albrecht
2 shared publications- Andreas Albrecht
Borealis Polyolefine GmbH, Innovation Headquarters
1 shared publication - Enrico Carmeli
Borealis Polyolefine GmbH, Innovat Headquarters, St Peter Str 25, A-4021 Linz, Austria
1 shared publication
Latest Publications
- Open Access
- 30 January 2024
- Published by Elsevier in Polymer Testing
- Vol. 131
A novel approach for accurate determination of polyethylene and polypropylene content in polyolefin blends and recyclates by cross-fractionation chromatography
- 30 January 2024
- Published by Elsevier in Polymer Testing
- Vol. 131
Open AccessA novel approach for accurate determination of polyethylene and polypropylene content in polyolefin blends and recyclates by cross-fractionation chromatography
- Open Access
- 29 April 2022
- Published by Wiley in Journal of Polymer Science
- Vol. 60 (24) , 3366-3378
Fast successive self‐nucleation and annealing (SSA) thermal fractionation protocol for the characterization of polyolefin blends from mechanical recycling
The sorting stage of mechanical recycling of post‐consumer polyolefins has severe challenges. Polypropylene (PP) is often contaminated with polyethylene (PE) and vice versa. To meet quality requirements, characterization of the recycled pellets is needed. To address this problem, fast characterization generating a statistical assessment of the content of the various batches from recycling is required. This investigation shows that the use of fast scanning rates (in a conventional Differential Scanning Calorimeter) in the successive self‐nucleation and annealing (SSA) protocol can reduce the thermal fractionation time, without losing resolution power, as long as the increase in heating/cooling rate is compensated by reducing sample mass. Using a “coupled SSA protocol” for polypropylene and polyethylene fractions at a rate of 10 °C/min, the measurement time is approximately 420 min. Implementing mass compensation, faster heating rates (i.e., 30 °C/min) and using a single‐fraction protocol, sufficient to determine the content of PP and high‐density PE, reduced the time of the measurement to 75 min. Examples of fractionations of commercial post‐consumer and post‐industrial recycled polyolefin blends conducted at a faster rate are provided. The derived polyolefin content is compared with the standard temperature rising elution fractionation analysis to assess the validity of the proposed method.
- 29 April 2022
- Published by Wiley in Journal of Polymer Science
- Vol. 60 (24) , 3366-3378
Open AccessFast successive self‐nucleation and annealing (SSA) thermal fractionation protocol for the characterization of polyolefin blends from mechanical recycling
The sorting stage of mechanical recycling of post‐consumer polyolefins has severe challenges. Polypropylene (PP) is often contaminated with polyethylene (PE) and vice versa. To meet quality requirements, characterization of the recycled pellets is needed. To address this problem, fast characterization generating a statistical assessment of the content of the various batches from recycling is required. This investigation shows that the use of fast scanning rates (in a conventional Differential Scanning Calorimeter) in the successive self‐nucleation and annealing (SSA) protocol can reduce the thermal fractionation time, without losing resolution power, as long as the increase in heating/cooling rate is compensated by reducing sample mass. Using a “coupled SSA protocol” for polypropylene and polyethylene fractions at a rate of 10 °C/min, the measurement time is approximately 420 min. Implementing mass compensation, faster heating rates (i.e., 30 °C/min) and using a single‐fraction protocol, sufficient to determine the content of PP and high‐density PE, reduced the time of the measurement to 75 min. Examples of fractionations of commercial post‐consumer and post‐industrial recycled polyolefin blends conducted at a faster rate are provided. The derived polyolefin content is compared with the standard temperature rising elution fractionation analysis to assess the validity of the proposed method.