BMBela Majorovits

Bela Majorovits

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bela Majorovits has a total of 349 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sensitivity of a closed dielectric haloscope to axion dark matter

    by A. Ivanov, D. Leppla-Weber, B. Ary dos Santos Garcia, D. Bergermann, H. Byun, A. Caldwell, V. Dabhi, C. Diaconu, J. Diehl, G. Dvali, et al.

    We present a method to determine the sensitivity of a closed dielectric haloscope to axion dark matter. Dielectric haloscopes aim to probe the theoretically well-motivated axion mass range of ∼ 26 µeV to ∼ 500 µeV by utilizing a stack of dielectric disks and a mirror to enhance the axion-photon conversion within an external magnetic field. Their conversion volume is nearly axion-mass independent, thereby favoring large-scale designs to increase sensitivity. The large volume causes simulations to be computationally expensive and time-consuming. This paper presents a simple model that can be used to determine the sensitivity of the experiment with minimal computational resources. The model is able to describe the electromagnetic response of a closed dielectric haloscope, accounting for realistic geometric imperfections, as well as the noise introduced by the receiver system. It is applied to data taken with a MAgnetized Disk and Mirror Axion Experiment (MADMAX) prototype within the 1.6 T Morpurgo magnet at CERN. This work underpins the first axion dark matter search using a dielectric haloscope and provides the foundation for future dark matter searches with MADMAX.

  • Top Cited Papers
    Open Access

    First Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment

    by H Acharya, N Ackermann, M Agostini, A Alexander, C Andreoiu, G R Araujo, F T Avignone, M Babicz, W Bae, A M Bakalyarov, et al.

    The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.


  • Open Access

    Non-magnetic glass-fiber cryostat for MADMAX prototype tests

    by D. Kreikemeyer-Lorenzo, T. Koettig, P. Borges de Sousa, C. Gooch, D. Kittlinger, B. Majorovits, J.P.A. Maldonado, P. Pralavorio

    MADMAX, an axion dark matter search experiment, is currently in the prototype testing phase. Its working principle is based on the conversion of axions in a magnetic field into photons. This signal is then enhanced by a booster made of dielectric disks placed in front of a mirror. In order to test MADMAX prototypes at cryogenic temperatures in a magnetic field parallel to the disks, a new G-10 glass-fiber cryostat of 0.06,m3 inner volume was designed, tested and used in a CERN magnet. The design allows to minimise cost as well as cooling down and warming up times. Using continuous circulation flow of gaseous helium, the MADMAX prototype was cooled down reproducibly to temperatures below 10 K for more than 24 hours. This procedure allowed, for the first time, to perform a calibration of the booster response and to run a dark matter axion search in a magnetic field at low temperatures. This novel type of cryostat, with a low manufacturing cost, fast and easy to operate, could be used for other purposes beyond MADMAX.


  • Development, Integration, and Test of the MACQU Demo Coil Toward MADMAX Quench Analysis

    by Clement Lorin, Walid Abdel Maksoud, Jerome Allard, Christophe Berriaud, Valerio Calvelli, Loic Denarie, Guillaume Dilasser, Thomas Donga, Yannick Drouen, Unai Duranona, et al.

    The MADMAX project aims at detecting axion dark matter in the mass range of 100 μeV. To facilitate axion to photon conversion with detectable rate a superconducting dipole magnet with a large bore is needed. The MADMAX dipole magnet has to generate ∼9 T in a 1.35 m aperture over ∼1.3 m in length. A key challenge for a magnet made of a cable in-conduit conductor (CICC), operating at 1.8 K with an indirect bath cooling is the quench detection. In order to validate feasibility, a mock-up coil with a quench behavior scalable to MADMAX was designed and produced. The paper gives an overview of the technical details of the MACQU test coil. The conductor, the magnet, the busbar and the supporting and cryogenic systems were designed at CEA. The cable was manufactured in China at the Chang Tong INC from WST Nb-Ti strands, the insertion and compaction was achieved in the ASIPP institute with a copper profile from Aurubis. The winding of the coil and the busbar pre-forming were performed at Bilfinger Noell as well as the assembly of the supporting structure and the thermal shield. The magnet was integrated in the JT60 test station at CEA Saclay and extensively tested. The magnet current reached 80% on the loadline instead of 90% as expected at nominal. The limitation is likely coming from uneven current distribution at the extremity of the magnet at the connection box location. Nevertheless, quench tests were successfully performed at constant currents from 10 kA to 17 kA. They proved that the initial quench velocities are of the order of 1 m/s to 10 m/s, high enough to safely detect a voltage drop in MADMAX and discharge the magnet. In addition, a thermo-hydraulic quench back effect was observed in the MACQU coil cooled by superfluid helium.


  • Top Cited Papers

    Direct detection of dark matter—APPEC committee report*

    by Julien Billard, Mark Boulay, Susana Cebrián, Laura Covi, Giuliana Fiorillo, Anne Green, Joachim Kopp, Béla Majorovits, Kimberly Palladino, Federica Petricca, et al.

    This report provides an extensive review of the experimental programme of direct detection searches of particle dark matter. It focuses mostly on European efforts, both current and planned, but does it within a broader context of a worldwide activity in the field. It aims at identifying the virtues, opportunities and challenges associated with the different experimental approaches and search techniques. It presents scientific and technological synergies, both existing and emerging, with some other areas of particle physics, notably collider and neutrino programmes, and beyond. It addresses the issue of infrastructure in light of the growing needs and challenges of the different experimental searches. Finally, the report makes a number of recommendations from the perspective of a long-term future of the field. They are introduced, along with some justification, in the opening overview and recommendations section and are next summarised at the end of the report. Overall, we recommend that the direct search for dark matter particle interactions with a detector target should be given top priority in astroparticle physics, and in all particle physics, and beyond, as a positive measurement will provide the most unambiguous confirmation of the particle nature of dark matter in the Universe.