Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ruifeng Wang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Data of short-term thermal energy storage strategy with medium-deep borehole heat exchanger

    by Jun Liu, Ruifeng Wang, Sheng Zhang, Zhaosong Fang

  • Open Access

    Soil Heat Deficit Regulation-Based Cross-Seasonal Heat Storage of Medium-Deep Borehole Heat Exchanger

    by Jun Liu, Yuping Zhang, Jingyue Zhang, Ruifeng Wang, Heng Shi, Sheng Zhang, Zhaosong Fang

    Medium-deep borehole heat exchanger (MBDHE) is a clean building heating solution that offers improved indoor thermal comfort, but it risks heat extraction capacity deterioration due to insufficient geothermal heat flux recovery. Cross-seasonal heat storage can mitigate heat extraction capacity deterioration. However, previous studies focused on optimizing the heat storage parameters without considering the mutual inhibition between geothermal heat flux recovery and the heat storage. This paper proposes a soil heat deficit regulation-based cross-seasonal heat storage method, which expands the soil heat deficit to enhance the geothermal heat flux recovery and heat storage simultaneously for improved heating performance of the MDBHE. The effectiveness of the proposed method is demonstrated by using an MDBHE model validated against actual engineering data. The results show that the flow rate-based soil heat deficit regulation is more effective than the temperature-based soil heat deficit regulation. Expanding the soil heat deficit by lowering the heat extraction temperature effectively increases the heat extraction capacity of MDBHE by up to 44.82% with a relatively stable heat storage efficiency. Expanding the soil heat deficit by increasing the heat extraction flow rate increases the heat extraction capacity by up to 55.93% and improves the heat storage efficiency by up to 18.71%. Furthermore, the robustness of the soil heat deficit regulation is verified under different heat storage conditions. Therefore, the proposed method can effectively improve the heating performance of MDBHE, enhancing indoor thermal comfort and contributing to the advancement of low-carbon building heating.


  • Open Access

    Numerical Investigation of the Long-Term Load Shifting Behaviors within the Borehole Heat Exchanger Array System

    by Haijiang Zou, Siyu Guo, Ruifeng Wang, Fenghao Wang, Zhenxing Shen, Wanlong Cai

    In the process of development and utilization of a large-scale borehole heat exchanger (BHE) array system, the phenomenon of load shifting within BHE array can be observed. In this paper, OpenGeoSys software coupled with TESPy toolkit is used to establish a comprehensive numerical model of BHE system (without depicting the heat pump part), and the behaviors of load shifting between BHEs with different design parameters are studied. The results show that the outlet temperature of single BHE and BHE array is generally rising, and the soil temperature around the BHE has accumulated unbalanced heat. The soil temperature near the BHEs array fluctuates more obviously than the single BHE system, and the distribution is uneven. At the end of the 15th year, the soil temperature near the center BHE increased by 2 °C compared with the initial soil temperature, which was more favorable in winter, but was not conducive to the performance improvement in summer. Further analysis by changing the inter-borehole spacing shows that with the increase of the inter-borehole spacing, the load shifting behaviors are gradually weakened, and the maximum shifted load of the central BHE is linear with the change of the inter-borehole spacing. After changing the layout methods, we observe that the more intensive the layout is, the more load shifting behavior is, and the unbalanced rate of soil temperature distribution around the linear layout is lower than other layouts. With the increase in the number of BHEs, the load shifting behaviors are further enhanced. By analyzing the proportion of shifted load amount relative to the average value, it is found that the system will take a longer time to reach heat balance with the increase of BHEs’ number. A shutdown of part of BHEs for a certain period of time will help to improve the long-term operational efficiency of the large-scale shallow ground source heat pump (GSHP) system.


  • Open Access

    Numerical Study on the Long-Term Performance and Load Imbalance Ratio for Medium-Shallow Borehole Heat Exchanger System

    by Ruifeng Wang, Fenghao Wang, Yuze Xue, Jinghua Jiang, Yuping Zhang, Wanlong Cai, Chaofan Chen

    To contribute to the goal of carbon neutralization, the closed-loop borehole heat exchanger system is widely applied to use geothermal energy for building cooling and heating. In this work, a new type of medium-shallow borehole heat exchanger (MSBHE) is proposed, which is coaxial type and has a depth range between 200 m to 500 m. To investigate the long-term performance of MSBHE in the area with unbalanced cooling and heating load of buildings and the sustainable load imbalance ratio under different design parameters, a comprehensive numerical model is established. The results show that the drilling depth significantly influences the sustainable load imbalance ratio of MSBHE. As the drilling depth is increased from 200 m to 500 m, the load imbalance ratio of the MSBHE increases from 20.76% to 60.29%. In contrast, the load imbalance ratio is always kept at the same level with different inlet velocities and operation modes. Furthermore, in a 9-MSBHE array system, the heat exchanger located in the middle of the array has the lowest load imbalance ratio of 48.97%, which is 15.98% lower than the borehole in the edge location. This is caused by the significant influence of the shifted-load phenomenon among MSBHEs in an array system. The findings of the work imply that this newly proposed MSBHE can sustain a notable load imbalance ratio, which is particularly applicable to the areas with a strong imbalance of annual building load.