Hufsa Arain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hufsa Arain has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chandra Mohan
Department Biomedical Engineering, University of Houston, United States
3 shared publications - David Wang
John Sealy School of Medicine, UT Medical Branch, Galveston, TX 77555, USA
2 shared publications - Janani Arunachalam
Department Biomedical Engineering, University of Houston, Houston, TX 77204, USA
2 shared publications - Ramesh Saxena
The University of Texas Southwestern Medical Center, USA
2 shared publications - Rongwei Lei
Department Biomedical Engineering, University of Houston, Houston, TX 77204, USA
2 shared publications - David Wang
Department of Biomedical Engineering, University of Houston, Houston, TX 77004, USA
1 shared publication
Latest Publications
- Open Access
- 12 February 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (2) , 98
Duplex Vertical-Flow Rapid Tests for Point-of-Care Detection of Anti-dsDNA and Anti-Nuclear Autoantibodies
The goal of this study is to develop a rapid diagnostic test for rheumatic disease and systemic lupus erythematosus (SLE) screening. A novel rapid vertical flow assay (VFA) was engineered and used to assay anti-nuclear (ANA) and anti-dsDNA (αDNA) autoantibodies from systemic lupus erythematosus (SLE) patients and healthy controls (HCs). Observer scores and absolute signal intensities from the VFA were validated via ELISA. The rapid point-of-care VFA test that was engineered demonstrated a limit of detection of 0.5 IU/mL for ANA and αDNA autoantibodies in human plasma with an inter-operator CV of 19% for ANA and 12% for αDNA. Storage stability was verified over a three-month period. When testing anti-dsDNA and ANA levels in SLE and HC serum samples, the duplex VFA revealed 95% sensitivity, 72% specificity and an 84% ROC AUC value in discriminating disease groups, comparable to the gold standard, ELISA. The rapid αDNA/ANA duplex VFA can potentially be used in primary care clinics for evaluating patients or at-risk subjects for rheumatic diseases and for planning follow-up testing. Given its low cost, ease, and rapid turnaround, it can also be used to assess SLE prevalence estimates.
- 12 February 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (2) , 98
Open AccessDuplex Vertical-Flow Rapid Tests for Point-of-Care Detection of Anti-dsDNA and Anti-Nuclear Autoantibodies
The goal of this study is to develop a rapid diagnostic test for rheumatic disease and systemic lupus erythematosus (SLE) screening. A novel rapid vertical flow assay (VFA) was engineered and used to assay anti-nuclear (ANA) and anti-dsDNA (αDNA) autoantibodies from systemic lupus erythematosus (SLE) patients and healthy controls (HCs). Observer scores and absolute signal intensities from the VFA were validated via ELISA. The rapid point-of-care VFA test that was engineered demonstrated a limit of detection of 0.5 IU/mL for ANA and αDNA autoantibodies in human plasma with an inter-operator CV of 19% for ANA and 12% for αDNA. Storage stability was verified over a three-month period. When testing anti-dsDNA and ANA levels in SLE and HC serum samples, the duplex VFA revealed 95% sensitivity, 72% specificity and an 84% ROC AUC value in discriminating disease groups, comparable to the gold standard, ELISA. The rapid αDNA/ANA duplex VFA can potentially be used in primary care clinics for evaluating patients or at-risk subjects for rheumatic diseases and for planning follow-up testing. Given its low cost, ease, and rapid turnaround, it can also be used to assess SLE prevalence estimates.
- Open Access
- 19 January 2024
- Published by MDPI AG in Preprints.org
Duplex vertical flow rapid tests for point-of-care detection of anti-dsDNA and anti-nuclear autoantibodies
The goal of this study was to develop a rapid diagnostic kit for rheumatic disease and systemic lupus erythematosus (SLE) screening. A novel rapid vertical flow assay (VFA) was engineered and used to assay anti-nuclear (ANA) and anti-dsDNA (αDNA) autoantibodies from systemic lupus erythematosus (SLE) patients and healthy controls (HC). Observer scores and absolute signal intensities from the VFA were validated by ELISA. The rapid ten minute point of care VFA test engineered demonstrated a limit of detection of 0.5 IU/ml for ANA and αDNA autoantibodies in human plasma with inter-operator CV of 19% for ANA and 12% for αDNA. Storage stability was verified over a three-month period. When testing anti-dsDNA and ANA levels in 22 SLE and 18 HC serum samples, the duplex VFA revealed 95% sensitivity, 72% specificity and 84% accuracy in discriminating disease groups, comparable to the gold standard, ELISA. The rapid αDNA/ANA duplex VFA can potentially be used in primary care clinics for evaluating patients or at-risk subjects for rheumatic diseases and for planning follow-up testing. Given its low cost, ease and rapid turnaround, it can also be used to assess SLE prevalence estimates.
- 19 January 2024
- Published by MDPI AG in Preprints.org
Open AccessDuplex vertical flow rapid tests for point-of-care detection of anti-dsDNA and anti-nuclear autoantibodies
The goal of this study was to develop a rapid diagnostic kit for rheumatic disease and systemic lupus erythematosus (SLE) screening. A novel rapid vertical flow assay (VFA) was engineered and used to assay anti-nuclear (ANA) and anti-dsDNA (αDNA) autoantibodies from systemic lupus erythematosus (SLE) patients and healthy controls (HC). Observer scores and absolute signal intensities from the VFA were validated by ELISA. The rapid ten minute point of care VFA test engineered demonstrated a limit of detection of 0.5 IU/ml for ANA and αDNA autoantibodies in human plasma with inter-operator CV of 19% for ANA and 12% for αDNA. Storage stability was verified over a three-month period. When testing anti-dsDNA and ANA levels in 22 SLE and 18 HC serum samples, the duplex VFA revealed 95% sensitivity, 72% specificity and 84% accuracy in discriminating disease groups, comparable to the gold standard, ELISA. The rapid αDNA/ANA duplex VFA can potentially be used in primary care clinics for evaluating patients or at-risk subjects for rheumatic diseases and for planning follow-up testing. Given its low cost, ease and rapid turnaround, it can also be used to assess SLE prevalence estimates.
- Open Access
- 28 April 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (5) , 1107
Design of Gold Nanoparticle Vertical Flow Assays for Point-of-Care Testing
Vertical flow assays (VFAs) or flow-through assays have emerged as an alternate type of paper-based assay due to their faster detection time, larger sample volume capacity, and significantly higher multiplexing capabilities. They have been successfully employed to detect several different targets (polysaccharides, protein, and nucleic acids), although in a limited number of samples (serum, whole blood, plasma) compared to the more commonly known lateral flow assays (LFAs). The operation of a VFA relies mainly on gravity, coupled with capillary action or external force to help the sample flow through layers of stacked pads. With recent developments in this field, multiple layers of pads and signal readers have been optimized for more user-friendly operation, and VFAs have achieved a lower limit of detection for various analytes than the gold-standard methods. Thus, compared to the more widely used LFA, the VFA demonstrates certain advantages and is becoming an increasingly popular platform for obtaining qualitative and quantitative results in low-resource settings. Considering the wide application of gold nanoparticles (GNPs) in VFAs, we will mostly discuss (1) the design of GNP-based VFA along with its associated advantages/disadvantages, (2) fabrication and optimization of GNP-based VFAs for applications, and (3) the future outlook of flow-based assays for point-of-care testing (POCT) diagnostics.
- 28 April 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (5) , 1107
Open AccessDesign of Gold Nanoparticle Vertical Flow Assays for Point-of-Care Testing
Vertical flow assays (VFAs) or flow-through assays have emerged as an alternate type of paper-based assay due to their faster detection time, larger sample volume capacity, and significantly higher multiplexing capabilities. They have been successfully employed to detect several different targets (polysaccharides, protein, and nucleic acids), although in a limited number of samples (serum, whole blood, plasma) compared to the more commonly known lateral flow assays (LFAs). The operation of a VFA relies mainly on gravity, coupled with capillary action or external force to help the sample flow through layers of stacked pads. With recent developments in this field, multiple layers of pads and signal readers have been optimized for more user-friendly operation, and VFAs have achieved a lower limit of detection for various analytes than the gold-standard methods. Thus, compared to the more widely used LFA, the VFA demonstrates certain advantages and is becoming an increasingly popular platform for obtaining qualitative and quantitative results in low-resource settings. Considering the wide application of gold nanoparticles (GNPs) in VFAs, we will mostly discuss (1) the design of GNP-based VFA along with its associated advantages/disadvantages, (2) fabrication and optimization of GNP-based VFAs for applications, and (3) the future outlook of flow-based assays for point-of-care testing (POCT) diagnostics.