IGIan Andrew Gardner

Ian Andrew Gardner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ian Andrew Gardner has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Inter‐Laboratory Comparison of qPCR Assays for Piscirickettsia salmonis in Atlantic Salmon (Salmo salar L.) in 11 Chilean Laboratories

    by Andrea Peña, Marco Rozas‐Serri, Ian A. Gardner, Benjamin Diethelm‐Varela, Carla Anguita, Carlos Navarro Jerez, Fernando O. Mardones

    Real‐time PCR (qPCR) testing is an essential component of early detection surveillance systems for Piscirickettsia salmonis infection in Atlantic salmon farms in Chile. Currently, all 11 laboratories in the authorised diagnostic laboratory network use assays based on published protocols. Compared with other P. salmonis qPCR assays, these assays have the advantage of targeting two different genes, that is, the 16S ribosomal gene and the internal transcribed spacer (ITS), potentially allowing for higher diagnostic accuracy. However, variation and lack of harmonisation of qPCR testing systems (e.g., primers/probe, RNA/DNA as target, extraction methods, etc.) may contribute to among‐laboratory variation in qPCR results and an increased frequency of false‐negative and false‐positive results. The purpose of the ring trial reported herein was to compare qPCR results from 11 laboratories in Chile routinely testing Atlantic salmon for P. salmonis as part of a national control program. The panel of 14 samples included duplicates of three concentrations of P. salmonis in a homogenised head kidney, LF89 and EM90 bacteria and two negative controls (blank and a suspension of Flavobacterium psychrophilum). The sample order was randomised across labs, samples were tested blinded and analysed without knowledge of the source lab. Of the laboratories, 8 (72.7%) had at least one incorrect result out of 14 tested samples. Low‐concentration samples (Ct of about 30) were more often incorrectly classified by reverse transcription‐qPCR (RT‐qPCR) (3/6 labs) than by qPCR (0/5). Six (54.5%) labs had at least one false‐positive result indicating that cross‐contamination was likely during sample processing. Affected laboratories are advised to conduct internal investigations to confirm the causes of false‐positive results and recommendations for design and implementation of future ring trials are discussed.


  • Open Access

    Bayesian estimation of sensitivity and specificity of a rapid mastitis test kit, bacterial culture, and PCR for detection of Staphylococcus aureus, Streptococcus species, and coliforms in bovine milk samples

    by Tapakorn Chamchoy, Emmanuel Okello, Deniece R. Williams, Karen Tonooka, Kathy Glenn, Koji Maehana, Ian A. Gardner, Sharif S. Aly

    Our objectives were to evaluate the diagnostic accuracy of a rapid and novel immunochromatography-based mastitis kit that includes 3 independent tests to detect coliforms (Escherichia coli or Klebsiella pneumoniae), Streptococcus spp., and Staphylococcus aureus. The kit was developed to facilitate diagnostic-based mastitis treatment. Validation of the kit was based on 154 aseptically collected mastitis samples from 2 clinical herds (clinical population) and 120 milk samples from 3 nonclinical herds (nonclinical population) without clinical cases at the time of enrollment. One herd sampled at different times was common to both populations. A 3-test in 2-population Bayesian latent class model with uniform priors for all test parameters except specificity of culture, which was modeled informatively, was used to estimate sensitivity (Se) and specificity (Sp) of the test kit, culture, and PCR at the cow level. The mastitis test kit's 96.9% Sp for Streptococcus spp. had a low false positive percentage (3.1%), which, together with the kit's rapid turnaround time for results, makes it a suitable initial screening test that producers can use to identify clinical cows to treat based on Streptococcus spp. mastitis in kit-positive results. Due to the 60.4% kit Se, producers should follow up on Streptococcus spp. kit-negative cows using a confirmatory test such as PCR (Sp of 98.4%) or culture (Sp of 99.6%). In contrast, aerobic culture had Se of 76.5% and Sp of 99.6% for Streptococcus spp. Similarly, the Sp of the kit (98.2%) and culture (99.8%) for Staph. aureus were particularly high, and even though the kit's Se (61.0%) was lower than culture (88.4%; posterior probability of difference 98%), the kit could be beneficial before use of a confirmatory test for kit-negative samples due to its ease and rapid turnaround time. Mostly, quantitative real-time (q)PCR outperformed the kit's Se (37.7%) and Sp (92.9%) for coliforms, as well as the kit's Se (60.4%) for Streptococcus spp. However, qPCR may require more technical skills and turnaround time for final results. Use of the on-farm mastitis test kit evaluated in the present study could enhance sustainable antimicrobial drug use by rapidly identifying Streptococcus mastitis for targeted treatment. Furthermore, the kit may be used in a Staph. aureus outbreak where cows can be rapidly screened to identify cases for segregation or culling during an outbreak and kit-negative cows further confirmed by milk culture or qPCR. However, the cost-effectiveness of such an approach has not been investigated.


  • Design standards for experimental and field studies to evaluate diagnostic accuracy of tests for infectious diseases in aquatic animals

    by E Laurin, K K Thakur, I A Gardner, P Hick, N J G Moody, M S J Crane, I Ernst

    Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial‐animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk‐of‐failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta‐analyses of DAS research literature.


  • Reliability of environmental sampling to quantify Mycobacterium avium subspecies paratuberculosis on California free-stall dairies

    by S.S. Aly, R.J. Anderson, R.H. Whitlock, T.L. Fyock, S. McAdams, J.M. Adaska, J. Jiang, I.A. Gardner

    The reliability of environmental sampling to quantify Mycobacterium avium ssp. paratuberculosis (MAP) based on collector and time was evaluated. Fecal slurry samples were collected using a standardized protocol simultaneously by 2 collectors of different experience levels. Samples were collected from 30 cow pens on 4 dairies every other day on 3 occasions while cow movements between pens were minimal. The 4 study herds had moderate MAP seroprevalence and were housed in free-stall dairies in central California. Results of testing the environmental samples for MAP using PCR and culture were strongly correlated. The reliability of environmental sampling simultaneously by different collectors as estimated by the intraclass correlation coefficient was excellent (81%) for PCR and good (67%) for culture and may justify comparison of quantitative results of samples collected by different investigators. The reliability of environmental sampling over a 5-d period was good (67 and 64% for PCR and culture results, respectively), which justifies the utility of environmental sampling to identify pens with a high MAP bioburden between routine cow pen changes on a dairy. Environmental sampling of free-stall pens using the standardized sampling protocol yielded comparable PCR and culture results across collectors with different experience levels and at different times within a 5-d period.


  • Open Access

    Observer variation in visual assessment of forelimb horseshoe characteristics on Thoroughbred racehorses

    by Diane K. Gross, Susan M. Stover, Ashley E. Hill, Ian A. Gardner

    Objective —To assess the accuracy and reliability of a visual method of evaluating horseshoe characteristics. Animals —1,199 Thoroughbred racehorses. Procedure —Characteristics of 1 forelimb horseshoe were visually assessed on horses immediately prior to racing by 5 field observers at 5 major racetracks in California. Characteristics evaluated included horseshoe type; toe grab height; and the presence of a rim, pad, and heel traction devices. Sensitivity and specificity for observer assessment of horseshoe characteristics were calculated by comparing observer assessments to a postmortem laboratory standard for horses that died within 48 hours of a race. Intraobserver agreement was assessed in a subset of horses by comparing horseshoe observations made before and after the horse's race. Interobserver agreement was evaluated by comparing horseshoe assessment among observers who examined the same subset of horses prior to racing on select days. Results —The sensitivity and specificity of this visual method of evaluating horseshoe characteristics were good and ranged from 0.75 to 1 and 0.67 to 1, respectively. Agreement beyond chance (weighted kappa values) between observers and the laboratory standard for toe grab height was fair (0.60 to 0.62). Intraobserver and interobserver agreements (kappa values) were high (0.86 to 0.99 and 0.71 to 1, respectively). Conclusions and Clinical Relevance —Visual observation of horseshoes can be a feasible and reproducible method for assessing horseshoe characteristics prospectively in a large cohort of horses under racing conditions. ( Am J Vet Res 2004;65:1674–1679)


  • RISK OF TRANSPLACENTAL TRANSMISSION OF SARCOCYSTIS NEURONA AND NEOSPORA HUGHESI IN CALIFORNIA HORSES

    by Paulo C. Duarte, Patricia A. Conrad, Bradd C. Barr, W. David Wilson, Gregory L. Ferraro, Andrea E. Packham, Tim E. Carpenter, Ian A. Gardner

    The study objective was to assess the risk of transplacental transmission of Sarcocystis neurona and Neospora hughesi in foals from 4 California farms during 3 foaling seasons. Serum of presuckle foals and serum and colostrum of periparturient mares were tested using indirect fluorescent antibody tests for S. neurona and N. hughesi. Serum antibody titers were ≤10 in 366 presuckle foals tested. There was no serologic or histologic evidence of either parasite in aborted fetuses or placentas examined. Positivity for S. neurona and N. hughesi in mares increased with age. Mares ≤9 yr that originated from Kentucky were 3.8 and 1.4 times more likely to be positive for S. neurona and N. hughesi, respectively, than mares from California. The strength of association between positivity to either parasite and state of birth decreased as age increased. Mares positive for S. neurona and N. hughesi were 2.2 and 1.7 times more likely, respectively, to have a previous abortion than negative mares, adjusted for age and sta...


  • Open Access

    Evaluation of the microcirculation of the equine jejunum and ascending colon after ischemia and reperfusion

    by Robin M. Dabareiner, Jack R. Snyder, Kenneth E. Sullins, Nathaniel A. White, Ian A. Gardner

    Summary: Intramural vascular patterns of the jejunum and colon were evaluated during ischemic strangulation obstruction (iso, 70 minutes) and subsequent reperfusion (60 minutes) in 7 adult anesthetized horses. Microvasculature of experimental and control segments was described by comparison of results from microangiography, light microscopy, and scanning electron microscopy of vascular replicas. Experimental and control segments with isolated vascular arcades were removed either immediately after the experimental period or after 60 minutes of reperfusion. Blood was flushed from the vascular system by use of isotonic NaCl, and the segments were divided. Half of each segment was perfused with a modified radiopaque medium for microangiographic evaluation, and half was perfused with dilute methylmethacrylate to create a vascular replica to be studied by scanning electron microscopy. Microangiographic section also were evaluated for histologic changes. Microvasculature of jejunal control segments and all colon segments was similar to described normal microvasculature of the equine jejunum and ascending colon. In jejunal iso segments, intramural perfusion was redistributed away from the mucosa. In the villi, the central arteriole was short and convoluted and the subepithelial capillaries were not filled. The submucosal vessels and crypt capillaries were congested, compared with those of controls, and the serosal vessels were not filled in the ischemic segments. Histologic grade II-III mucosal lesion was seen in jejunal iso segments. Reperfused jejunal segments had a transmural hyperemic response, and previously unfilled capillaries were observed in all intestinal layers. After reperfusion, the mucosal lesion progressed to grade III-IV and a cellular infiltrate and edema formation were observed in the serosa. The intramural vasculature of the ischemic and reperfused colon remain unchanged. Minimal histologic damage was observed in the colon after 70 minutes of iso or after 60 minutes of reperfusion.