Jothiraj Selvaraj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jothiraj Selvaraj has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Sameera Fathimal Mohamed Ali
Department of Biomedical Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
6 shared publications - Umapathy Snekhalatha
Department of Biomedical Engineering, college of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India
6 shared publications - Jayanthy Ak
Department of Medical Engineering, Sri Ramachandra Faculty of Engineering and Technology Sri Ramachandra Institute of Higher Education and Research Chennai India
3 shared publications - Fadiyah Almutairi
Department of Information System, College of Computer and Information Sciences (CCIS), Majmaah University, Al Majmaah 11952, Saudi Arabia
2 shared publications M. Sameera Fathimal
Department of Biomedical Engineering, SRM Institute of Science and Technology, Kattankulathur, Chengalpattu 603203, Tamil Nadu, India
2 shared publications- S. P. Angeline Kirubha
SRM Inst Sci & Technol, Coll Engn & Technol, Dept Biomed Engn, Kattankulathur 603203, Tamil Nadu, India
2 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (21) , 4102
A Hybrid-Structure Framework for Multivariable Health Assessment and Conditional Short-Horizon Projection
A mathematically transparent framework is developed for assessing a person’s current health status and conditionally projecting the status to a selected future time. The method uses a hybrid structure in which each biomedical parameter contributes both a set of supported monitoring states and a fuzzy confidence value. Eight specific physiological and metabolic parameters are converted by means of explicit and repeatable fuzzy calibrations, followed by combination of fuzzy and set-valued information to form an aggregate monitoring vector and Hybrid Health Severity Index. A local trend model is developed using recent observations, and the same hybrid approach is used for future evaluation. There are three synthetic illustrations given here to demonstrate the computations, including one with a deliberately severe profile to examine the upper end of the proposed scale. The work is purely methodological, and validation of the calibrations on clinical data is required before any health care application.
- 9 November 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (21) , 4102
Open AccessA Hybrid-Structure Framework for Multivariable Health Assessment and Conditional Short-Horizon Projection
A mathematically transparent framework is developed for assessing a person’s current health status and conditionally projecting the status to a selected future time. The method uses a hybrid structure in which each biomedical parameter contributes both a set of supported monitoring states and a fuzzy confidence value. Eight specific physiological and metabolic parameters are converted by means of explicit and repeatable fuzzy calibrations, followed by combination of fuzzy and set-valued information to form an aggregate monitoring vector and Hybrid Health Severity Index. A local trend model is developed using recent observations, and the same hybrid approach is used for future evaluation. There are three synthetic illustrations given here to demonstrate the computations, including one with a deliberately severe profile to examine the upper end of the proposed scale. The work is purely methodological, and validation of the calibrations on clinical data is required before any health care application.
- Open Access
- 13 August 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Advancing Parkinson’s detection from MRI: a deep learning comparison of classical and quantum architectures
Purpose: The precise diagnosis of Parkinson’s Disease (PD) continues to pose a considerable barrier in clinical neurology. This work investigates the capability of sophisticated deep learning architectures to improve Parkinson’s disease identification via Magnetic Resonance Imaging (MRI) scans, aiming to improve diagnostic sensitivity and specificity. Method: This research implements an automated PD classification framework utilizing deep learning models to analyze real-time MRI scans. CNN models and Transformers that leverages the inherent spatial information within MRI scans for automated feature extraction and classification of PD was implemented. The comparative analysis of diverse architectures aimed to discern the optimal feature extraction and classification strategies for distinguishing PD-affected brains from healthy controls was performed. K-fold cross-validation was conducted to evaluate the reliability of dataset partitioning and to ensure model generalizability. Results: The QNN demonstrated superior performance during training and validation with accuracy of 0.9851 and 0.9731 respectively. Among the Transformer-based architectures, the Swin Transformer achieved a training and validation accuracy of 0.9712 & 0.9673. In the category of CNN-based models, ResNet50 exhibited the highest accuracy, attaining 0.9322 during training and 0.9192 during validation. The K-fold cross-validation results corroborated the stability and consistency of the model performances with the 80:20 data split, reinforcing the robustness of the proposed approach. Furthermore, to assess the generalizability of the best-performing model, an external validation was conducted using the Parkinson’s Progression Markers Initiative (PPMI) dataset. The results demonstrated comparable performance trends, thereby confirming the adaptability of the DL model to independent datasets. Conclusion: This study’s findings highlight the capability of deep learning-driven neuroimaging analysis in facilitating automated and precise PD diagnosis. This investigation provides a scalable and clinically viable AI framework that enhances diagnostic accuracy, thereby supporting clinicians in disease detection and improving patient management strategies.
- 13 August 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Open AccessAdvancing Parkinson’s detection from MRI: a deep learning comparison of classical and quantum architectures
Purpose: The precise diagnosis of Parkinson’s Disease (PD) continues to pose a considerable barrier in clinical neurology. This work investigates the capability of sophisticated deep learning architectures to improve Parkinson’s disease identification via Magnetic Resonance Imaging (MRI) scans, aiming to improve diagnostic sensitivity and specificity. Method: This research implements an automated PD classification framework utilizing deep learning models to analyze real-time MRI scans. CNN models and Transformers that leverages the inherent spatial information within MRI scans for automated feature extraction and classification of PD was implemented. The comparative analysis of diverse architectures aimed to discern the optimal feature extraction and classification strategies for distinguishing PD-affected brains from healthy controls was performed. K-fold cross-validation was conducted to evaluate the reliability of dataset partitioning and to ensure model generalizability. Results: The QNN demonstrated superior performance during training and validation with accuracy of 0.9851 and 0.9731 respectively. Among the Transformer-based architectures, the Swin Transformer achieved a training and validation accuracy of 0.9712 & 0.9673. In the category of CNN-based models, ResNet50 exhibited the highest accuracy, attaining 0.9322 during training and 0.9192 during validation. The K-fold cross-validation results corroborated the stability and consistency of the model performances with the 80:20 data split, reinforcing the robustness of the proposed approach. Furthermore, to assess the generalizability of the best-performing model, an external validation was conducted using the Parkinson’s Progression Markers Initiative (PPMI) dataset. The results demonstrated comparable performance trends, thereby confirming the adaptability of the DL model to independent datasets. Conclusion: This study’s findings highlight the capability of deep learning-driven neuroimaging analysis in facilitating automated and precise PD diagnosis. This investigation provides a scalable and clinically viable AI framework that enhances diagnostic accuracy, thereby supporting clinicians in disease detection and improving patient management strategies.
- Open Access
Binary and Multi-Class Classification of Colorectal Polyps Using CRP-ViT: A Comparative Study Between CNNs and QNNs
Background: Colorectal cancer (CRC) is a major contributor to cancer mortality on a global scale, with polyps being critical precursors. The accurate classification of colorectal polyps (CRPs) from colonoscopy images is essential for the timely diagnosis and treatment of CRC. Method: This research proposes a novel hybrid model, CRP-ViT, integrating ResNet50 with Vision Transformers (ViTs) to enhance feature extraction and improve classification performance. This study conducted a comprehensive comparison of the CRP-ViT model against traditional convolutional neural networks (CNNs) and emerging quantum neural networks (QNNs). Experiments were conducted for binary classification to predict the presence of polyps and multi-classification to predict specific polyp types (hyperplastic, adenomatous, and serrated). Results: The results demonstrate that CRPQNN-ViT achieved superior classification performance while maintaining computational efficiency. CRPQNN-ViT achieved an accuracy of 98.18% for training and 97.73% for validation on binary classification and 98.13% during training and 97.92% for validation on multi-classification tasks. In addition to the key metrics, computational parameters were compared, where CRPQNN-ViT excelled in computational time. Conclusions: This comparative analysis reveals the potential of integrating quantum computing into medical image analysis and underscores the effectiveness of transformer-based architectures for CRP classification.
Open AccessBinary and Multi-Class Classification of Colorectal Polyps Using CRP-ViT: A Comparative Study Between CNNs and QNNs
Background: Colorectal cancer (CRC) is a major contributor to cancer mortality on a global scale, with polyps being critical precursors. The accurate classification of colorectal polyps (CRPs) from colonoscopy images is essential for the timely diagnosis and treatment of CRC. Method: This research proposes a novel hybrid model, CRP-ViT, integrating ResNet50 with Vision Transformers (ViTs) to enhance feature extraction and improve classification performance. This study conducted a comprehensive comparison of the CRP-ViT model against traditional convolutional neural networks (CNNs) and emerging quantum neural networks (QNNs). Experiments were conducted for binary classification to predict the presence of polyps and multi-classification to predict specific polyp types (hyperplastic, adenomatous, and serrated). Results: The results demonstrate that CRPQNN-ViT achieved superior classification performance while maintaining computational efficiency. CRPQNN-ViT achieved an accuracy of 98.18% for training and 97.73% for validation on binary classification and 98.13% during training and 97.92% for validation on multi-classification tasks. In addition to the key metrics, computational parameters were compared, where CRPQNN-ViT excelled in computational time. Conclusions: This comparative analysis reveals the potential of integrating quantum computing into medical image analysis and underscores the effectiveness of transformer-based architectures for CRP classification.
- Open Access
- 20 May 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (10) , 1285
Multiclassification of Colorectal Polyps from Colonoscopy Images Using AI for Early Diagnosis
Background/Objectives: Colorectal cancer (CRC) remains one of the leading causes of cancer-related mortality worldwide, emphasizing the critical need for the accurate classification of precancerous polyps. This research presents an extensive analysis of the multiclassification framework leveraging various deep learning (DL) architectures for the automated classification of colorectal polyps from colonoscopy images. Methods: The proposed methodology integrates real-time data for training and utilizes a publicly available dataset for testing, ensuring generalizability. The real-time images were cautiously annotated and verified by a panel of experts, including post-graduate medical doctors and gastroenterology specialists. The DL models were designed to categorize the preprocessed colonoscopy images into four clinically significant classes: hyperplastic, serrated, adenoma, and normal. A suite of state-of-the-art models, including VGG16, VGG19, ResNet50, DenseNet121, EfficientNetV2, InceptionNetV3, Vision Transformer (ViT), and the custom-developed CRP-ViT, were trained and rigorously evaluated for this task. Results: Notably, the CRP-ViT model exhibited superior capability in capturing intricate features, achieving an impressive accuracy of 97.28% during training and 96.02% during validation with real-time images. Furthermore, the model demonstrated remarkable performance during testing on the public dataset, attaining an accuracy of 95.69%. To facilitate real-time interaction and clinical applicability, a user-friendly interface was developed using Gradio, allowing healthcare professionals to upload colonoscopy images and receive instant classification results. Conclusions: The CRP-ViT model effectively predicts and categorizes colonoscopy images into clinically relevant classes, aiding gastroenterologists in decision-making. This study highlights the potential of integrating AI-driven models into routine clinical practice to improve colorectal cancer screening outcomes and reduce diagnostic variability.
- 20 May 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (10) , 1285
Open AccessMulticlassification of Colorectal Polyps from Colonoscopy Images Using AI for Early Diagnosis
Background/Objectives: Colorectal cancer (CRC) remains one of the leading causes of cancer-related mortality worldwide, emphasizing the critical need for the accurate classification of precancerous polyps. This research presents an extensive analysis of the multiclassification framework leveraging various deep learning (DL) architectures for the automated classification of colorectal polyps from colonoscopy images. Methods: The proposed methodology integrates real-time data for training and utilizes a publicly available dataset for testing, ensuring generalizability. The real-time images were cautiously annotated and verified by a panel of experts, including post-graduate medical doctors and gastroenterology specialists. The DL models were designed to categorize the preprocessed colonoscopy images into four clinically significant classes: hyperplastic, serrated, adenoma, and normal. A suite of state-of-the-art models, including VGG16, VGG19, ResNet50, DenseNet121, EfficientNetV2, InceptionNetV3, Vision Transformer (ViT), and the custom-developed CRP-ViT, were trained and rigorously evaluated for this task. Results: Notably, the CRP-ViT model exhibited superior capability in capturing intricate features, achieving an impressive accuracy of 97.28% during training and 96.02% during validation with real-time images. Furthermore, the model demonstrated remarkable performance during testing on the public dataset, attaining an accuracy of 95.69%. To facilitate real-time interaction and clinical applicability, a user-friendly interface was developed using Gradio, allowing healthcare professionals to upload colonoscopy images and receive instant classification results. Conclusions: The CRP-ViT model effectively predicts and categorizes colonoscopy images into clinically relevant classes, aiding gastroenterologists in decision-making. This study highlights the potential of integrating AI-driven models into routine clinical practice to improve colorectal cancer screening outcomes and reduce diagnostic variability.
- 1 November 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065050
Pioneering diabetes screening tool: machine learning driven optical vascular signal analysis
The escalating prevalence of diabetes mellitus underscores the critical need for non-invasive screening tools capable of early disease detection. Present diagnostic techniques depend on invasive procedures, which highlights the need for advancement of non-invasive alternatives for initial disease detection. Machine learning in integration with the optical sensing technology can effectively analyze the signal patterns associated with diabetes. The objective of this research is to develop and evaluate a non-invasive optical-based method combined with machine learning algorithms for the classification of individuals into normal, prediabetic, and diabetic categories. A novel device was engineered to capture real-time optical vascular signals from participants representing the three glycemic states. The signals were then subjected to quality assessment and preprocessing to ensure data reliability. Subsequently, feature extraction was performed using time-domain analysis and wavelet scattering techniques to derive meaningful characteristics from the optical signals. The extracted features were subsequently employed to train and validate a suite of machine learning algorithms. An ensemble bagged trees classifier with wavelet scattering features and random forest classifier with time-domain features demonstrated superior performance, achieving an overall accuracy of 86.6% and 80.0% in differentiating between normal, prediabetic, and diabetic individuals based on the optical vascular signals. The proposed non-invasive optical-based approach, coupled with advanced machine learning techniques, holds promise as a potential screening tool for diabetes mellitus. The classification accuracy achieved in this study warrants further investigation and validation in larger and more diverse populations.
- 1 November 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065050
Pioneering diabetes screening tool: machine learning driven optical vascular signal analysis
The escalating prevalence of diabetes mellitus underscores the critical need for non-invasive screening tools capable of early disease detection. Present diagnostic techniques depend on invasive procedures, which highlights the need for advancement of non-invasive alternatives for initial disease detection. Machine learning in integration with the optical sensing technology can effectively analyze the signal patterns associated with diabetes. The objective of this research is to develop and evaluate a non-invasive optical-based method combined with machine learning algorithms for the classification of individuals into normal, prediabetic, and diabetic categories. A novel device was engineered to capture real-time optical vascular signals from participants representing the three glycemic states. The signals were then subjected to quality assessment and preprocessing to ensure data reliability. Subsequently, feature extraction was performed using time-domain analysis and wavelet scattering techniques to derive meaningful characteristics from the optical signals. The extracted features were subsequently employed to train and validate a suite of machine learning algorithms. An ensemble bagged trees classifier with wavelet scattering features and random forest classifier with time-domain features demonstrated superior performance, achieving an overall accuracy of 86.6% and 80.0% in differentiating between normal, prediabetic, and diabetic individuals based on the optical vascular signals. The proposed non-invasive optical-based approach, coupled with advanced machine learning techniques, holds promise as a potential screening tool for diabetes mellitus. The classification accuracy achieved in this study warrants further investigation and validation in larger and more diverse populations.
- 22 July 2024
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 36 (06)
ADVANCING COLORECTAL POLYP DETECTION: AN AUTOMATED SEGMENTATION APPROACH WITH COLRECTSEG-UNET
Purpose: This study aimed to achieve two primary goals. First, we sought to develop a lightweight convolutional neural network (CNN) model, COLRECTSEG-UNet, for the purpose of automated polyp segmentation and localization. Second, we evaluated the generalizability of the proposed model by testing it on a proprietary colonoscopy image dataset (own dataset) in addition to a publicly available benchmark (CVC-ColonDB and Kvasir dataset). Methods: The COLRECTSEG-UNet architecture was employed to perform polyp segmentation. Subsequently, the model was trained and validated using an 80:20 data split from the CVC-ColonDB dataset. The efficacy of these data split was confirmed through [ ] -fold cross-validation. To elucidate the significance of each layer within the COLRECTSEG-UNet design, an ablation study was conducted. The performance of the model was assessed using various metrics on the CVC-ClinicDB, own dataset and Kvasir dataset during the testing phase. These metrics were then compared to those achieved by current state-of-the-art models and findings reported in recent literature. Results: When evaluated on the CVC-ClinicDB dataset, the COLRECTSEG-UNet model achieved outstanding accuracy of 0.9591, intersection over union (IoU) of 0.9299 and F1-Score of 0.9530. Similarly, impressive results were obtained on the own dataset, with accuracy, IoU and F1-Score values of 0.955, 0.9346 and 0.9539, respectively. Additionally, Kvasir dataset attained the accuracy, IoU and F1-Score of 0.9542, 0.9291 and 0.9565, respectively. These results demonstrate that the proposed COLRECTSEG-UNet outperforms the existing benchmark models and surpasses the performance reported in current literature. Conclusion: The implementation of COLRECTSEG-UNet as a lightweight model paves the way for its integration as a backend component within medical imaging system software. This has the potential to significantly aid gastroenterologists in clinical decision-making during interventions.
- 22 July 2024
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 36 (06)
ADVANCING COLORECTAL POLYP DETECTION: AN AUTOMATED SEGMENTATION APPROACH WITH COLRECTSEG-UNET
Purpose: This study aimed to achieve two primary goals. First, we sought to develop a lightweight convolutional neural network (CNN) model, COLRECTSEG-UNet, for the purpose of automated polyp segmentation and localization. Second, we evaluated the generalizability of the proposed model by testing it on a proprietary colonoscopy image dataset (own dataset) in addition to a publicly available benchmark (CVC-ColonDB and Kvasir dataset). Methods: The COLRECTSEG-UNet architecture was employed to perform polyp segmentation. Subsequently, the model was trained and validated using an 80:20 data split from the CVC-ColonDB dataset. The efficacy of these data split was confirmed through [ ] -fold cross-validation. To elucidate the significance of each layer within the COLRECTSEG-UNet design, an ablation study was conducted. The performance of the model was assessed using various metrics on the CVC-ClinicDB, own dataset and Kvasir dataset during the testing phase. These metrics were then compared to those achieved by current state-of-the-art models and findings reported in recent literature. Results: When evaluated on the CVC-ClinicDB dataset, the COLRECTSEG-UNet model achieved outstanding accuracy of 0.9591, intersection over union (IoU) of 0.9299 and F1-Score of 0.9530. Similarly, impressive results were obtained on the own dataset, with accuracy, IoU and F1-Score values of 0.955, 0.9346 and 0.9539, respectively. Additionally, Kvasir dataset attained the accuracy, IoU and F1-Score of 0.9542, 0.9291 and 0.9565, respectively. These results demonstrate that the proposed COLRECTSEG-UNet outperforms the existing benchmark models and surpasses the performance reported in current literature. Conclusion: The implementation of COLRECTSEG-UNet as a lightweight model paves the way for its integration as a backend component within medical imaging system software. This has the potential to significantly aid gastroenterologists in clinical decision-making during interventions.
- 12 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1527-1531
MRI Image Segmentation for Schizophrenia Diagnosis Using a Modified U-Net Architecture
In order to effectively manage the progressive nature of schizophrenia, accurate characterization of the Lateral Ventricles in MRI scans is essential. Clinicians often face challenges in detecting ventricles due to potential blending with background pixels. Moreover, the clinician’s cognitive state significantly impacts accurate identification of affected brain regions. The aim of the study involves automated segmentation of lateral ventricles in the Schizophrenia using Modified U-Net method. We trained and validated the Modified U-Net using Open Neuro datasets, tuning hyperparameters for optimal performance. The adam optimizer produced better accuracy of 94.56% compared to RMS in U-Net segmentation. Our results show an Mean Intersection over Union (mIoU) of 0.9198, and mF1 of 0.9342 in U-Net segmentation. The use of the Modified U-Net to localize lateral ventricles in medical imaging has the potential to enhance schizophrenia early diagnosis.
- 12 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1527-1531
MRI Image Segmentation for Schizophrenia Diagnosis Using a Modified U-Net Architecture
In order to effectively manage the progressive nature of schizophrenia, accurate characterization of the Lateral Ventricles in MRI scans is essential. Clinicians often face challenges in detecting ventricles due to potential blending with background pixels. Moreover, the clinician’s cognitive state significantly impacts accurate identification of affected brain regions. The aim of the study involves automated segmentation of lateral ventricles in the Schizophrenia using Modified U-Net method. We trained and validated the Modified U-Net using Open Neuro datasets, tuning hyperparameters for optimal performance. The adam optimizer produced better accuracy of 94.56% compared to RMS in U-Net segmentation. Our results show an Mean Intersection over Union (mIoU) of 0.9198, and mF1 of 0.9342 in U-Net segmentation. The use of the Modified U-Net to localize lateral ventricles in medical imaging has the potential to enhance schizophrenia early diagnosis.
- 5 February 2024
- Published by Wiley in International Journal of Imaging Systems and Technology
Design and development of artificial intelligence‐based application programming interface for early detection and diagnosis of colorectal cancer from wireless capsule endoscopy images
The colorectal cancer (CRC) is gaining attention in the context of gastrointestinal tract diseases as it ranks third among the most prevalent type of cancer. The early diagnosis of the CRC can be done by periodic examination of the colon and rectum for innocuous tissue abnormality called polyp as it has the potential to evolve as malignant in future. The CRC diagnosis using wireless capsule endoscopy requires the dedicated commitment of the medical expert demanding significant time, focus and effort. The accuracy of manual analysis in identifying polyps is extensively reliant on the cognitive condition of the physician, thus emphasizing the requirement for automatic polyp identification. The artificial intelligence integrated computer-aided diagnosis system could assist the clinician in better diagnosis, thereby reducing the miss-rates of polyps. In our proposed study, we developed an application program interface to aid the clinician in automatic segmentation of the polyp and evaluation of its dimension by manual placement of four landmarks on the predicted polyp. The segmentation is performed by the proposed light weight Padded U-Net for the effective polyp segmentation in the colorectal images. We trained and validated the Padded U-Net with augmented images of Kvasir dataset and calculated the performance parameters. In order to facilitate image augmentation, a graphical user interface called Augment Tree was developed, which incorporates 92 augmentation techniques. The accuracy, recall, precision, IoU, F1-score, loss achieved during validation of Padded U-Net were 95.6%, 0.946%, 0.985%, 0.933%, 0.965% and 0.080% respectively. We demonstrated that accuracy was improved and loss was reduced when the model was trained with augmented images rather than only the limited original dataset images. On comparison of our Padded U-net architecture with recently developed architectures, our model attained optimal performance in all the metrics except accuracy in which it attained marginal performance to the highest value.
- 5 February 2024
- Published by Wiley in International Journal of Imaging Systems and Technology
Design and development of artificial intelligence‐based application programming interface for early detection and diagnosis of colorectal cancer from wireless capsule endoscopy images
The colorectal cancer (CRC) is gaining attention in the context of gastrointestinal tract diseases as it ranks third among the most prevalent type of cancer. The early diagnosis of the CRC can be done by periodic examination of the colon and rectum for innocuous tissue abnormality called polyp as it has the potential to evolve as malignant in future. The CRC diagnosis using wireless capsule endoscopy requires the dedicated commitment of the medical expert demanding significant time, focus and effort. The accuracy of manual analysis in identifying polyps is extensively reliant on the cognitive condition of the physician, thus emphasizing the requirement for automatic polyp identification. The artificial intelligence integrated computer-aided diagnosis system could assist the clinician in better diagnosis, thereby reducing the miss-rates of polyps. In our proposed study, we developed an application program interface to aid the clinician in automatic segmentation of the polyp and evaluation of its dimension by manual placement of four landmarks on the predicted polyp. The segmentation is performed by the proposed light weight Padded U-Net for the effective polyp segmentation in the colorectal images. We trained and validated the Padded U-Net with augmented images of Kvasir dataset and calculated the performance parameters. In order to facilitate image augmentation, a graphical user interface called Augment Tree was developed, which incorporates 92 augmentation techniques. The accuracy, recall, precision, IoU, F1-score, loss achieved during validation of Padded U-Net were 95.6%, 0.946%, 0.985%, 0.933%, 0.965% and 0.080% respectively. We demonstrated that accuracy was improved and loss was reduced when the model was trained with augmented images rather than only the limited original dataset images. On comparison of our Padded U-net architecture with recently developed architectures, our model attained optimal performance in all the metrics except accuracy in which it attained marginal performance to the highest value.