Jonathan Bouvette
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jonathan Bouvette has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Mario Juan Borgnia
Genome Integrity and Structural Biology Laboratory, National Institute of Environmental Health Sciences, National Institutes of Health, Department of Health and Human Services, Research Triangle Park, NC, USA
5 shared publications - Alberto Bartesaghi
Department of Biochemistry, Duke University School of Medicine, Durham, NC, 27710, USA; Department of Computer Science, Duke University, Durham, NC, 27708, USA; Department of Electrical and Computer Engineering, Duke University, Durham, NC, 27708, USA
4 shared publications - Amanda A. Riccio
Genome Integrity and Structural Biology Laboratory, National Institute of Environmental Health Sciences
3 shared publications - Qinwen Huang
Department of Computer Science, Duke University, Durham, USA
3 shared publications - William C. Copeland
Genome Integrity and Structural Biology Laboratory, Mitochondrial DNA Replication Group, National Institute of Environmental Health Sciences, National Institutes of Health , Research Triangle Park, NC 27709
3 shared publications Andrew West
Duke University
1 shared publication
Latest Publications
- Open Access
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 1019
Expanding the Reach of Cryo-EM through Open Design Robotics and Remote Screening
Propelled by improvements in hardware for data collection and processing, single particle cryo-electron microscopy has rapidly gained relevance in structural biology. Yet, finding the conditions to stabilize a macromolecular target for imaging remains the most critical step in determining its structure. Attaining the optimal specimen requires the evaluation of multiple grids in a microscope as conditions are varied. While automation has significantly increased the speed of data collection, optimization is still carried out manually. This laborious process, which is highly dependent on subjective assessments, inefficient and prone to error, often determines the success of a project. When relying on remote facilities the process is even more cumbersome. Protein samples can be unstable when transported on ice or subjected to freeze and thaw cycles. Even when vitrified specimens can be prepared locally, lack of direct access to the screening instruments poses a significant barrier to optimization.
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 1019
Open AccessExpanding the Reach of Cryo-EM through Open Design Robotics and Remote Screening
Propelled by improvements in hardware for data collection and processing, single particle cryo-electron microscopy has rapidly gained relevance in structural biology. Yet, finding the conditions to stabilize a macromolecular target for imaging remains the most critical step in determining its structure. Attaining the optimal specimen requires the evaluation of multiple grids in a microscope as conditions are varied. While automation has significantly increased the speed of data collection, optimization is still carried out manually. This laborious process, which is highly dependent on subjective assessments, inefficient and prone to error, often determines the success of a project. When relying on remote facilities the process is even more cumbersome. Protein samples can be unstable when transported on ice or subjected to freeze and thaw cycles. Even when vitrified specimens can be prepared locally, lack of direct access to the screening instruments poses a significant barrier to optimization.
- Open Access
- 23 August 2022
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 11
Automated systematic evaluation of cryo-EM specimens with SmartScope
Finding the conditions to stabilize a macromolecular target for imaging remains the most critical barrier to determining its structure by cryo-electron microscopy (cryo-EM). While automation has significantly increased the speed of data collection, specimens are still screened manually, a laborious and subjective task that often determines the success of a project. Here, we present SmartScope, the first framework to streamline, standardize, and automate specimen evaluation in cryo-EM. SmartScope employs deep-learning-based object detection to identify and classify features suitable for imaging, allowing it to perform thorough specimen screening in a fully automated manner. A web interface provides remote control over the automated operation of the microscope in real time and access to images and annotation tools. Manual annotations can be used to re-train the feature recognition models, leading to improvements in performance. Our automated tool for systematic evaluation of specimens streamlines structure determination and lowers the barrier of adoption for cryo-EM.
- 23 August 2022
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 11
Open AccessAutomated systematic evaluation of cryo-EM specimens with SmartScope
Finding the conditions to stabilize a macromolecular target for imaging remains the most critical barrier to determining its structure by cryo-electron microscopy (cryo-EM). While automation has significantly increased the speed of data collection, specimens are still screened manually, a laborious and subjective task that often determines the success of a project. Here, we present SmartScope, the first framework to streamline, standardize, and automate specimen evaluation in cryo-EM. SmartScope employs deep-learning-based object detection to identify and classify features suitable for imaging, allowing it to perform thorough specimen screening in a fully automated manner. A web interface provides remote control over the automated operation of the microscope in real time and access to images and annotation tools. Manual annotations can be used to re-train the feature recognition models, leading to improvements in performance. Our automated tool for systematic evaluation of specimens streamlines structure determination and lowers the barrier of adoption for cryo-EM.
- Open Access
- 1 August 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (32)
Structural insight and characterization of human Twinkle helicase in mitochondrial disease
Twinkle is the mammalian helicase vital for replication and integrity of mitochondrial DNA. Over 90 Twinkle helicase disease variants have been linked to progressive external ophthalmoplegia and ataxia neuropathies among other mitochondrial diseases. Despite the biological and clinical importance, Twinkle represents the only remaining component of the human minimal mitochondrial replisome that has yet to be structurally characterized. Here, we present 3-dimensional structures of human Twinkle W315L. Employing cryo-electron microscopy (cryo-EM), we characterize the oligomeric assemblies of human full-length Twinkle W315L, define its multimeric interface, and map clinical variants associated with Twinkle in inherited mitochondrial disease. Cryo-EM, crosslinking-mass spectrometry, and molecular dynamics simulations provide insight into the dynamic movement and molecular consequences of the W315L clinical variant. Collectively, this ensemble of structures outlines a framework for studying Twinkle function in mitochondrial DNA replication and associated disease states.
- 1 August 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (32)
Open AccessStructural insight and characterization of human Twinkle helicase in mitochondrial disease
Twinkle is the mammalian helicase vital for replication and integrity of mitochondrial DNA. Over 90 Twinkle helicase disease variants have been linked to progressive external ophthalmoplegia and ataxia neuropathies among other mitochondrial diseases. Despite the biological and clinical importance, Twinkle represents the only remaining component of the human minimal mitochondrial replisome that has yet to be structurally characterized. Here, we present 3-dimensional structures of human Twinkle W315L. Employing cryo-electron microscopy (cryo-EM), we characterize the oligomeric assemblies of human full-length Twinkle W315L, define its multimeric interface, and map clinical variants associated with Twinkle in inherited mitochondrial disease. Cryo-EM, crosslinking-mass spectrometry, and molecular dynamics simulations provide insight into the dynamic movement and molecular consequences of the W315L clinical variant. Collectively, this ensemble of structures outlines a framework for studying Twinkle function in mitochondrial DNA replication and associated disease states.
- Open Access
- 22 July 2022
- Published by Springer Nature in Research Square
Structural and functional landscape of α-synuclein fibril conformations amplified from cerebrospinal fluid
Lewy body dementias are pathologically defined by the deposition of α-synuclein fibrils into inclusions throughout the brain. Cerebrospinal fluid(CSF) in disease harbors circulating α-synuclein-fibril seeds, and parental α-synuclein fibrils can template core structure into amplified fibrils. Using cryo-electron microscopy, we identify six novel α-synuclein fibril assemblies amplified from ten CSF samples (3.8Å to 2.9Å nominal resolutions). Fibrils are classified based on two types of filament interaction, two types of β-sheet stacking, and two types of hydrophobic pocket. CSF-amplified fibril products have one, two, or three distinct assemblies each. Six of ten samples share a common fibril assembly. Within this classification, the fibrils have distinct profiles in amyloid dye binding, and dramatically different potencies in both seeding new inclusions in neurons and evoked microglial pro-inflammatory responses. However, no single structural feature predicts functional phenotypes. Our results highlight CSF as a valuable resource to identify novel α-synuclein assemblies potentially important in disease.
- 22 July 2022
- Published by Springer Nature in Research Square
Open AccessStructural and functional landscape of α-synuclein fibril conformations amplified from cerebrospinal fluid
Lewy body dementias are pathologically defined by the deposition of α-synuclein fibrils into inclusions throughout the brain. Cerebrospinal fluid(CSF) in disease harbors circulating α-synuclein-fibril seeds, and parental α-synuclein fibrils can template core structure into amplified fibrils. Using cryo-electron microscopy, we identify six novel α-synuclein fibril assemblies amplified from ten CSF samples (3.8Å to 2.9Å nominal resolutions). Fibrils are classified based on two types of filament interaction, two types of β-sheet stacking, and two types of hydrophobic pocket. CSF-amplified fibril products have one, two, or three distinct assemblies each. Six of ten samples share a common fibril assembly. Within this classification, the fibrils have distinct profiles in amyloid dye binding, and dramatically different potencies in both seeding new inclusions in neurons and evoked microglial pro-inflammatory responses. However, no single structural feature predicts functional phenotypes. Our results highlight CSF as a valuable resource to identify novel α-synuclein assemblies potentially important in disease.
- Open Access
Automated systematic evaluation of cryo-EM specimens with SmartScope
Propelled by improvements in hardware for data collection and processing, single particle cryo-electron microscopy has rapidly gained relevance in structural biology. Yet, finding the conditions to stabilize a macromolecular target for imaging remains the most critical barrier to determining its structure. Attaining the optimal specimen requires the evaluation of multiple grids in a microscope as conditions are varied. While automation has significantly increased the speed of data collection, optimization is still carried out manually. This laborious process which is highly dependent on subjective assessments, inefficient and prone to error, often determines the success of a project. Here, we present SmartScope, the first framework to streamline, standardize, and automate specimen evaluation in cryo-electron microscopy. SmartScope employs deep-learning-based object detection to identify and classify features suitable for imaging, allowing it to perform thorough specimen screening in a fully automated manner. A web interface provides remote control over the automated operation of the microscope in real time and access to images and annotation tools. Manual annotations can be used to re-train the feature recognition models, leading to improvements in performance. Our automated tool for systematic evaluation of specimens streamlines structure determination and lowers the barrier of adoption for cryo-electron microscopy.
Open AccessAutomated systematic evaluation of cryo-EM specimens with SmartScope
Propelled by improvements in hardware for data collection and processing, single particle cryo-electron microscopy has rapidly gained relevance in structural biology. Yet, finding the conditions to stabilize a macromolecular target for imaging remains the most critical barrier to determining its structure. Attaining the optimal specimen requires the evaluation of multiple grids in a microscope as conditions are varied. While automation has significantly increased the speed of data collection, optimization is still carried out manually. This laborious process which is highly dependent on subjective assessments, inefficient and prone to error, often determines the success of a project. Here, we present SmartScope, the first framework to streamline, standardize, and automate specimen evaluation in cryo-electron microscopy. SmartScope employs deep-learning-based object detection to identify and classify features suitable for imaging, allowing it to perform thorough specimen screening in a fully automated manner. A web interface provides remote control over the automated operation of the microscope in real time and access to images and annotation tools. Manual annotations can be used to re-train the feature recognition models, leading to improvements in performance. Our automated tool for systematic evaluation of specimens streamlines structure determination and lowers the barrier of adoption for cryo-electron microscopy.