Han Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Han Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Toshiyuki Enomoto
Division of Mechanical Engineering, Graduate School of Engineering, The University of Osaka, Suita, Japan
4 shared publicationsUrara Satake
3 shared publications- Hirotatsu Imai
Department of Orthopaedic Surgery, The University of Osaka Graduate School of Medicine, 2-2 Yamadaoka, Suita 565-0871, Japan
1 shared publication - Koki Hosozawa
Department of Artificial Intelligence Diagnostic Radiology, The University of Osaka Graduate School of Medicine, Suita 565-0871, Japan
1 shared publication - Koki Kishimoto
Department of Orthopaedic Surgery, The University of Osaka Graduate School of Medicine, 2-2 Yamadaoka, Suita 565-0871, Japan
1 shared publication - Kosuke Kita
Department of Artificial Intelligence Diagnostic Radiology, The University of Osaka Graduate School of Medicine, Suita 565-0871, Japan
1 shared publication
Latest Publications
- 19 October 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-16
Turning-Point Impact Compromises the Biomechanical Integrity of Cortical Bone During Oscillating Sawing
- 19 October 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-16
Turning-Point Impact Compromises the Biomechanical Integrity of Cortical Bone During Oscillating Sawing
- Open Access
Feasibility of Drill-Tip Position Estimation During Cortical Bone Drilling Using Force and Torque Signals
Purpose: Excessive drill advancement after cortical breakthrough is a potential safety concern in orthopaedic procedures. We developed a data-driven approach to estimate the drill-tip position relative to the far cortex prior to breakthrough using time-series thrust force and spindle torque signals. Methods: Drilling experiments were performed on 268 porcine cortical bone specimens at a constant feed rate of 0.5 mm/s. A long short-term memory network was trained to estimate the drill-tip position from filtered force and torque signals. The reference position was derived from breakthrough timing confirmed by high-speed imaging and the programmed feed rate. Performance was evaluated using mean absolute error within the −2 to +2 mm peri-breakthrough interval. Two post hoc analyses examined whether model performance exceeded an elapsed-time baseline and whether pre-breakthrough force patterns were more consistent when expressed relative to breakthrough position than to drilling onset time. Results: The combined-input LSTM achieved an MAE of 0.20 mm, compared with 0.23 mm for force alone and 0.24 mm for torque alone. Among the representative architectures evaluated, LSTM showed the lowest regression error. A signal-blind time-only baseline yielded an MAE of 0.54 mm. The association between cortical thickness and force-decline onset was weaker when expressed in spatial coordinates relative to breakthrough than when expressed as time from drilling onset (R2 = 23% vs. 74%). These findings suggest that force and torque signals contained information associated with proximity to breakthrough beyond that provided by average drilling duration alone. Conclusion: Converting sensor-derived resistance patterns into spatially anchored positional information may support proactive strategies such as controlled deceleration before penetration. The proposed approach represents a step toward exemplifying the emerging concept of surgeon-assisting Physical AI.
Open AccessFeasibility of Drill-Tip Position Estimation During Cortical Bone Drilling Using Force and Torque Signals
Purpose: Excessive drill advancement after cortical breakthrough is a potential safety concern in orthopaedic procedures. We developed a data-driven approach to estimate the drill-tip position relative to the far cortex prior to breakthrough using time-series thrust force and spindle torque signals. Methods: Drilling experiments were performed on 268 porcine cortical bone specimens at a constant feed rate of 0.5 mm/s. A long short-term memory network was trained to estimate the drill-tip position from filtered force and torque signals. The reference position was derived from breakthrough timing confirmed by high-speed imaging and the programmed feed rate. Performance was evaluated using mean absolute error within the −2 to +2 mm peri-breakthrough interval. Two post hoc analyses examined whether model performance exceeded an elapsed-time baseline and whether pre-breakthrough force patterns were more consistent when expressed relative to breakthrough position than to drilling onset time. Results: The combined-input LSTM achieved an MAE of 0.20 mm, compared with 0.23 mm for force alone and 0.24 mm for torque alone. Among the representative architectures evaluated, LSTM showed the lowest regression error. A signal-blind time-only baseline yielded an MAE of 0.54 mm. The association between cortical thickness and force-decline onset was weaker when expressed in spatial coordinates relative to breakthrough than when expressed as time from drilling onset (R2 = 23% vs. 74%). These findings suggest that force and torque signals contained information associated with proximity to breakthrough beyond that provided by average drilling duration alone. Conclusion: Converting sensor-derived resistance patterns into spatially anchored positional information may support proactive strategies such as controlled deceleration before penetration. The proposed approach represents a step toward exemplifying the emerging concept of surgeon-assisting Physical AI.
- 23 November 2023
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 324
Modeling of oscillating bone sawing forces with instantaneous cutting speed and depth of cut
- 23 November 2023
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 324
Modeling of oscillating bone sawing forces with instantaneous cutting speed and depth of cut
- 19 July 2023
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 319
Serrated chip formation mechanism in orthogonal cutting of cortical bone at small depths of cut
- 19 July 2023
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 319
Serrated chip formation mechanism in orthogonal cutting of cortical bone at small depths of cut
- 7 May 2022
- Published by Elsevier in CIRP Annals
- Vol. 71 (1) , 73-76
Surgical oscillating saw blade to suppress forces in bone cutting
- 7 May 2022
- Published by Elsevier in CIRP Annals
- Vol. 71 (1) , 73-76
Surgical oscillating saw blade to suppress forces in bone cutting