Subhradip Mondal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Subhradip Mondal has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Dattatraya Narayan Gaonkar
Department of Electrical and Electronics Engineering National Institute of Technology Karnataka Srinivasnagar, Surathkal Mangaluru 575025 Karnataka India nitk.ac.in
3 shared publications - Pritam Kumar Gayen
Electrical Engineering Department, Kalyani Government Engineering College, Kalyani, India
3 shared publications
Latest Publications
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 949-958
A Fast and Robust PLL Design with a Combination of Frequency-Adaptive Alpha-Beta-CDSC and SOGI
Recent research has focused on the enhancement of the prefiltering capability of phase-locked loops (PLL). The cascaded delayed signal cancellation (CDSC) PLL removes the low-order selective harmonic frequencies near the fundamental frequency. Here, a frequency-adaptive time delay unit is used to cope with frequency and phase variations of voltage. The high-frequency signal arising due to the frequency-adaptive loop cannot be mitigated. In effect, the transient response of adaptive CDSC-PLL shows a significant irregular pattern. Therefore, this article suggests the use of a second-order generalized integrator (SOGI) after the adaptive CDSC unit to improve the transient profile of frequency response. In the design, the high gain (K $=$ 5.4) of SOGI is chosen to quickly settle the response of PLL at the expense of its ignorance of lower-order harmonics near the fundamental frequency. However, the lower-order harmonics are selectively eliminated by the CDSC unit. So, both prefilters complement each other's filtering capabilities. Additionally, the suggested prefilter provides improved noise immunity and eliminates DC offset via the SOGI unit. The linearized model and tuning procedure for the different control parameters of the proposed PLL are described. The real-time hardware-in-loop tests are executed to justify the optimum performance of the proposed PLL.
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 949-958
A Fast and Robust PLL Design with a Combination of Frequency-Adaptive Alpha-Beta-CDSC and SOGI
Recent research has focused on the enhancement of the prefiltering capability of phase-locked loops (PLL). The cascaded delayed signal cancellation (CDSC) PLL removes the low-order selective harmonic frequencies near the fundamental frequency. Here, a frequency-adaptive time delay unit is used to cope with frequency and phase variations of voltage. The high-frequency signal arising due to the frequency-adaptive loop cannot be mitigated. In effect, the transient response of adaptive CDSC-PLL shows a significant irregular pattern. Therefore, this article suggests the use of a second-order generalized integrator (SOGI) after the adaptive CDSC unit to improve the transient profile of frequency response. In the design, the high gain (K $=$ 5.4) of SOGI is chosen to quickly settle the response of PLL at the expense of its ignorance of lower-order harmonics near the fundamental frequency. However, the lower-order harmonics are selectively eliminated by the CDSC unit. So, both prefilters complement each other's filtering capabilities. Additionally, the suggested prefilter provides improved noise immunity and eliminates DC offset via the SOGI unit. The linearized model and tuning procedure for the different control parameters of the proposed PLL are described. The real-time hardware-in-loop tests are executed to justify the optimum performance of the proposed PLL.
- 21 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 17 (2) , 3005-3015
A Hybrid Islanding Detection Method Based on Lissajous Pattern Having Robust Performance Under Various Power Quality Scenarios
A fast, accurate, robust, and two-staged islanding detection technique (IDT) is proposed. It is the hybridization of second-order general integrator-frequency locked loop (SOGI-FLL), Lissajous pattern (LP), and active power absorption-cum-reactive power injection via dc-bus connected battery unit-based inverter. The LP is used to identify islanding condition on the basis of frequency variation of fundamental voltage. Here, the measured ac voltage signal is preprocessed by SOGI-FLL to obtain fundamental bus voltage under various power quality scenarios. This assures robust islanding detection by removing uncertainty, and thus, reliability is improved. The uncertainty effects due to the partial shading condition of the PV module (source-side disturbance) and weak grid-connected condition are avoided by dc-bus connected battery storage unit. Thus, it removes above-said limitations of the existing scheme. The LP-based detection within the nondetection zone is expedited due to active and reactive powers variation via controlling of the inverter and charging operation of the dc-bus connected battery unit. During the reactive power injection by solar inverter, active power is absorbed by dc-bus connected battery unit. In effect, an active power output of the inverter is reduced. Here, the reactive power injection at the reduced active power output condition of the inverter accelerates frequency variation allowing rapid islanding detection. The real-time experiments are carried out using Typhoon-HIL tools to compare the proposed method with other works reported in the literature. Improved performances under diversified scenarios are found in the proposed case.
- 21 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 17 (2) , 3005-3015
A Hybrid Islanding Detection Method Based on Lissajous Pattern Having Robust Performance Under Various Power Quality Scenarios
A fast, accurate, robust, and two-staged islanding detection technique (IDT) is proposed. It is the hybridization of second-order general integrator-frequency locked loop (SOGI-FLL), Lissajous pattern (LP), and active power absorption-cum-reactive power injection via dc-bus connected battery unit-based inverter. The LP is used to identify islanding condition on the basis of frequency variation of fundamental voltage. Here, the measured ac voltage signal is preprocessed by SOGI-FLL to obtain fundamental bus voltage under various power quality scenarios. This assures robust islanding detection by removing uncertainty, and thus, reliability is improved. The uncertainty effects due to the partial shading condition of the PV module (source-side disturbance) and weak grid-connected condition are avoided by dc-bus connected battery storage unit. Thus, it removes above-said limitations of the existing scheme. The LP-based detection within the nondetection zone is expedited due to active and reactive powers variation via controlling of the inverter and charging operation of the dc-bus connected battery unit. During the reactive power injection by solar inverter, active power is absorbed by dc-bus connected battery unit. In effect, an active power output of the inverter is reduced. Here, the reactive power injection at the reduced active power output condition of the inverter accelerates frequency variation allowing rapid islanding detection. The real-time experiments are carried out using Typhoon-HIL tools to compare the proposed method with other works reported in the literature. Improved performances under diversified scenarios are found in the proposed case.
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
Battery Storage-Based Novel Hybrid Islanding Detection Technique Using Lissajous Pattern Estimation
The reliability, uncertainty and sensitivity of local islanding detection method for distributed generation system under diversified real-time scenarios and non-linear loading conditions are not greatly explored. In this paper, a new type hybrid islanding detection technique (IDT) is suggested, which reduces uncertainty and simultaneously improves reliability and sensitivity under different situations. In the technique, one detection parameter is defined, which is calculated from estimation of major- and minor-axis of Lissajous Pattern (LP). Here, evaluation of the parameter is done in two stages to avoid erroneous detection. In first stage, initiation of voltage transient is detected by LP. In the second stage, the active control via battery energy storage system (BESS) distinguishes nuisance tripping case from islanding state. The extra active power injection/absorption via BESS also helps to identify islanding state at very near to zero power condition i.e. sensitivity is enhanced. The detection time is found within 160 ms for different test cases, which is well below that of the acceptable upper value (2 s) specified in standard. The uncertainties in detection and threshold setting due to variations of harmonics and other operating conditions are removed in proposed case, which is a distinct advantage. The Typhoon-HIL tool is used to carry out various case studies in real-time. Here, superior performances of proposed approach are observed in comparison with other state-of-arts reported in the literatures.
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
Battery Storage-Based Novel Hybrid Islanding Detection Technique Using Lissajous Pattern Estimation
The reliability, uncertainty and sensitivity of local islanding detection method for distributed generation system under diversified real-time scenarios and non-linear loading conditions are not greatly explored. In this paper, a new type hybrid islanding detection technique (IDT) is suggested, which reduces uncertainty and simultaneously improves reliability and sensitivity under different situations. In the technique, one detection parameter is defined, which is calculated from estimation of major- and minor-axis of Lissajous Pattern (LP). Here, evaluation of the parameter is done in two stages to avoid erroneous detection. In first stage, initiation of voltage transient is detected by LP. In the second stage, the active control via battery energy storage system (BESS) distinguishes nuisance tripping case from islanding state. The extra active power injection/absorption via BESS also helps to identify islanding state at very near to zero power condition i.e. sensitivity is enhanced. The detection time is found within 160 ms for different test cases, which is well below that of the acceptable upper value (2 s) specified in standard. The uncertainties in detection and threshold setting due to variations of harmonics and other operating conditions are removed in proposed case, which is a distinct advantage. The Typhoon-HIL tool is used to carry out various case studies in real-time. Here, superior performances of proposed approach are observed in comparison with other state-of-arts reported in the literatures.