Kun Liu
Kun Liu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Gert Rietveld
University of Twente, Enschede, The Netherlands
2 shared publications - Hui Yu
Philips Healthcare (Suzhou) Company, Ltd., Suzhou, China
2 shared publications - Jelena Popovic
Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, NB, The Netherlands
2 shared publications - Keqiu Zeng
Philips Healthcare (Suzhou) Company, Ltd., Suzhou, China
2 shared publications - Liguo Wang
Philips Healthcare (Suzhou) Company, Ltd., Suzhou, China
2 shared publications - Saijun Mao
Delft Netherlands 2628
2 shared publications
Latest Publications
- 25 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 10594-10608
Resolution Improvement in a High-Power Magnetic Resonance Imaging Gradient Power Amplifier
High-resolution gradient power amplifiers are required to generate high-fidelity gradient fields in magnetic resonance imaging (MRI) systems. Various aspects of gradient power amplifiers have been the subject of research in the past years, however, systematic analysis and design methods for its resolution improvement have not been sufficiently addressed. This article addresses this research gap with comprehensive analysis and design methods for resolution improvement. First, a method for systematic resolution characterization of the MRI gradient power amplifier with gradient coil is proposed. Second, noise modeling with respect to the critical aspects in the system resolution degradation is developed and discussed. Third, the resolution improvement methods of bandwidth optimization, pseudorandom code modulation, and utilizing silicon carbide (SiC) switching power devices are proposed and analyzed, achieving a resolution at the one part in ${10^6}$ level. Finally, the resolution improvement methods are experimentally validated in a 1000 V/400 A SiC gradient power amplifier. The experimental results show a 3.6 times reduction in the peak spurious signals and resolution improvement at all current levels and pulse lengths, compared to a conventional insulated gate bipolar transistor GPA. These results prove the validity of the proposed methods for resolution improvement in a high-power MRI gradient power amplifier, enabling future high-power and high-resolution amplifier designs.
- 25 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 10594-10608
Resolution Improvement in a High-Power Magnetic Resonance Imaging Gradient Power Amplifier
High-resolution gradient power amplifiers are required to generate high-fidelity gradient fields in magnetic resonance imaging (MRI) systems. Various aspects of gradient power amplifiers have been the subject of research in the past years, however, systematic analysis and design methods for its resolution improvement have not been sufficiently addressed. This article addresses this research gap with comprehensive analysis and design methods for resolution improvement. First, a method for systematic resolution characterization of the MRI gradient power amplifier with gradient coil is proposed. Second, noise modeling with respect to the critical aspects in the system resolution degradation is developed and discussed. Third, the resolution improvement methods of bandwidth optimization, pseudorandom code modulation, and utilizing silicon carbide (SiC) switching power devices are proposed and analyzed, achieving a resolution at the one part in ${10^6}$ level. Finally, the resolution improvement methods are experimentally validated in a 1000 V/400 A SiC gradient power amplifier. The experimental results show a 3.6 times reduction in the peak spurious signals and resolution improvement at all current levels and pulse lengths, compared to a conventional insulated gate bipolar transistor GPA. These results prove the validity of the proposed methods for resolution improvement in a high-power MRI gradient power amplifier, enabling future high-power and high-resolution amplifier designs.
- 3 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (8) , 9035-9046
High-Precision Control Method for High-Power MRI Gradient Power Amplifiers
In magnetic resonance imaging (MRI), high-power gradient power amplifiers (GPAs) are required to drive the gradient coils to generate strong and high-fidelity gradient fields. High precision is an essential requirement for the GPAs since precision directly impacts MRI imaging quality. Various aspects of the GPA have been the subject of research in the past years; however, high-precision GPA control that meets the stringent requirements of MRI applications is still a challenge. This article proposes a novel multi-rational-delay variables state space control method and an efficient out-of-band signal injection method to achieve GPA control accuracy at the level of one part per million at MVA output power levels. First, a systematic modeling and design method of the state space controller for high-power GPA is introduced utilizing state vectors with multi-rational-delay variables. This method improves the GPA dynamic performance significantly. Second, an efficient out-of-band signal injection method is presented to further improve the control precision at low output current, enabling the fulfillment of the challenging high-precision MRI requirements over the full GPA output range. Finally, the high-precision control method is validated in a GPA demonstrator with 500 A/1000 V output. Key results are a 30% improvement in current pulse reproducibility with respect to the conventional control method and a factor of 2.5 less noise at low currents. These experimental results validate the proposed novel method for the high-precision control of GPAs in MRI applications and prove its capability to contribute to significantly improved MRI image quality.
- 3 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (8) , 9035-9046
High-Precision Control Method for High-Power MRI Gradient Power Amplifiers
In magnetic resonance imaging (MRI), high-power gradient power amplifiers (GPAs) are required to drive the gradient coils to generate strong and high-fidelity gradient fields. High precision is an essential requirement for the GPAs since precision directly impacts MRI imaging quality. Various aspects of the GPA have been the subject of research in the past years; however, high-precision GPA control that meets the stringent requirements of MRI applications is still a challenge. This article proposes a novel multi-rational-delay variables state space control method and an efficient out-of-band signal injection method to achieve GPA control accuracy at the level of one part per million at MVA output power levels. First, a systematic modeling and design method of the state space controller for high-power GPA is introduced utilizing state vectors with multi-rational-delay variables. This method improves the GPA dynamic performance significantly. Second, an efficient out-of-band signal injection method is presented to further improve the control precision at low output current, enabling the fulfillment of the challenging high-precision MRI requirements over the full GPA output range. Finally, the high-precision control method is validated in a GPA demonstrator with 500 A/1000 V output. Key results are a 30% improvement in current pulse reproducibility with respect to the conventional control method and a factor of 2.5 less noise at low currents. These experimental results validate the proposed novel method for the high-precision control of GPAs in MRI applications and prove its capability to contribute to significantly improved MRI image quality.
- 26 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
High Voltage PNP Device Using RESURF Structure for Above 40V ESD Protection
A high voltage PNP device is designed with a small footprint by applying the RESURF technique. It has low turn-on resistance and high failure current. Adjusting the length of LOCOS, the PNP device shows flexibility for different voltage applications from 40V to 90V without failure current degradation.
- 26 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
High Voltage PNP Device Using RESURF Structure for Above 40V ESD Protection
A high voltage PNP device is designed with a small footprint by applying the RESURF technique. It has low turn-on resistance and high failure current. Adjusting the length of LOCOS, the PNP device shows flexibility for different voltage applications from 40V to 90V without failure current degradation.
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21574839,p. 1-4
The All-digital Electrical Energy Metering System Based on Optical Current and Voltage Transducer
The communication protocol structure of digital substation in smart grid has changed greatly, and the electrical energy metering system is changed greatly too. In this paper, an all-digital electrical energy metering system based on pure optical voltage transducer (OVT) and optical current transducer (OCT) is introduced. The advanced communication protocol IEC618509-2 is adopted in the all-digital electrical metering system firstly. And in this paper, the difference between traditional electrical energy metering system and all-digital electrical energy metering system is analyzed and compared in principle, and the benefits of all-digital electrical energy metering system are described. The realization of the proposed all-digital electrical energy metering system on a 220 kV voltage grade power system is described. The results of running show that the developed all-digital electrical energy metering has the performances of high accuracy, high reliability and high safety.
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21574839,p. 1-4
The All-digital Electrical Energy Metering System Based on Optical Current and Voltage Transducer
The communication protocol structure of digital substation in smart grid has changed greatly, and the electrical energy metering system is changed greatly too. In this paper, an all-digital electrical energy metering system based on pure optical voltage transducer (OVT) and optical current transducer (OCT) is introduced. The advanced communication protocol IEC618509-2 is adopted in the all-digital electrical metering system firstly. And in this paper, the difference between traditional electrical energy metering system and all-digital electrical energy metering system is analyzed and compared in principle, and the benefits of all-digital electrical energy metering system are described. The realization of the proposed all-digital electrical energy metering system on a 220 kV voltage grade power system is described. The results of running show that the developed all-digital electrical energy metering has the performances of high accuracy, high reliability and high safety.