Telmo Bento
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Telmo Bento has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Humberto Bustince
Universidad Pública de Navarra
1 shared publication - Pedro Couto
Centre for the Research and Technology of Agro-Environmental and Biological Sciences (CITAB), University of Trás-os-Montes e Alto Douro (UTAD), 5000-801 Vila Real, Portugal
1 shared publication - Pedro Melo-Pinto
CITAB, Universidade de Trás-os-Montes e Alto Douro, Vila Real, Portugal
1 shared publication
Latest Publications
- Open Access
- 11 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (10) , 4865
Positron Emission Tomography Image Segmentation Based on Atanassov’s Intuitionistic Fuzzy Sets
In this paper, we present an approach to fully automate tumor delineation in positron emission tomography (PET) images. PET images play a major role in medicine for in vivo imaging in oncology (PET images are used to evaluate oncology patients, detecting emitted photons from a radiotracer localized in abnormal cells). PET image tumor delineation plays a vital role both in pre- and post-treatment stages. The low spatial resolution and high noise characteristics of PET images increase the challenge in PET image segmentation. Despite the difficulties and known limitations, several image segmentation approaches have been proposed. This paper introduces a new unsupervised approach to perform tumor delineation in PET images using Atanassov’s intuitionistic fuzzy sets (A-IFSs) and restricted dissimilarity functions. Moreover, the implementation of this methodology is presented and tested against other existing methodologies. The proposed algorithm increases the accuracy of tumor delineation in PET images, and the experimental results show that the proposed method outperformed all methods tested.
- 11 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (10) , 4865
Open AccessPositron Emission Tomography Image Segmentation Based on Atanassov’s Intuitionistic Fuzzy Sets
In this paper, we present an approach to fully automate tumor delineation in positron emission tomography (PET) images. PET images play a major role in medicine for in vivo imaging in oncology (PET images are used to evaluate oncology patients, detecting emitted photons from a radiotracer localized in abnormal cells). PET image tumor delineation plays a vital role both in pre- and post-treatment stages. The low spatial resolution and high noise characteristics of PET images increase the challenge in PET image segmentation. Despite the difficulties and known limitations, several image segmentation approaches have been proposed. This paper introduces a new unsupervised approach to perform tumor delineation in PET images using Atanassov’s intuitionistic fuzzy sets (A-IFSs) and restricted dissimilarity functions. Moreover, the implementation of this methodology is presented and tested against other existing methodologies. The proposed algorithm increases the accuracy of tumor delineation in PET images, and the experimental results show that the proposed method outperformed all methods tested.