Kun Qian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kun Qian has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Peng Chen
10 shared publicationsYifeng E
9 shared publicationsZhuozhe Li
Jinzhou Medical University, Jinzhou, 121001, PR China
9 shared publicationsFang Fang
Jinzhou Medical University
7 shared publicationsLi Li
7 shared publications- Yifeng E
Jinzhou Medical University, Jinzhou, 121001, PR China
7 shared publications
Latest Publications
- 13 July 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (7) , 5646-5661
Magnetic-Optical Dual-Modality Imaging Monitoring Oxaliplatin through the Crystalline Mn-Metal–Organic Framework Sensor
To support image-assisted evaluation of anticancer drugs in biological settings, functional sensing materials are needed to integrate sensitive molecular detection with imaging-compatible readouts. Oxaliplatin (OHP) is widely used in chemotherapy, and accurate OHP assessment in biological matrices remains important for dosage optimization and toxicity management. Herein, a nanosized Mn-MOF was prepared as a fluorescence sensor and MRI-responsive platform for OHP-associated detection. The structure, morphology, elemental distribution, and Mn surface electronic state of the Mn-MOF were characterized by XRD, SEM, AFM, EDS mapping, XPS, and DLS. Mn-MOF showed limited dialyzable Mn leakage, and retained fluorescence stability and MRI signal stability during 28 days of storage. As a T1 MRI contrast platform, Mn-MOF exhibited a longitudinal relaxivity (r1) of 6.38 mM–1 s–1 at 3.0 T and showed OHP-dependent T1 signal attenuation over the tested OHP concentration range of 0.5–10 mM. Preliminary in vivo MRI experiments showed liver and kidney T1 enhancement after intravenous Mn-MOF administration and OHP-associated attenuation of the Mn-MOF-enhanced signal. In fluorescence mode, the Mn-MOF nanosensor exhibited concentration-dependent quenching toward OHP in ultrapure water over 0.33 fM–18.2 μM, with a calibration-model-based estimated limit of detection (LOD) of 41.1 aM under the stated Mn-MOF-assisted fluorescence sensing conditions. The sensor also showed selectivity under the tested interference conditions, spiked-rabbit-serum calibration and recovery performance, and 28-day fluorescence response stability. Hemolysis, H&E staining, KGN and HK-2 cell-viability assays indicated preliminary hemocompatibility and cytocompatibility under the tested conditions. This dual-modal design provides a preliminary strategy for integrating optical OHP sensing with MRI readout in a single Mn-MOF platform.
- 13 July 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (7) , 5646-5661
Magnetic-Optical Dual-Modality Imaging Monitoring Oxaliplatin through the Crystalline Mn-Metal–Organic Framework Sensor
To support image-assisted evaluation of anticancer drugs in biological settings, functional sensing materials are needed to integrate sensitive molecular detection with imaging-compatible readouts. Oxaliplatin (OHP) is widely used in chemotherapy, and accurate OHP assessment in biological matrices remains important for dosage optimization and toxicity management. Herein, a nanosized Mn-MOF was prepared as a fluorescence sensor and MRI-responsive platform for OHP-associated detection. The structure, morphology, elemental distribution, and Mn surface electronic state of the Mn-MOF were characterized by XRD, SEM, AFM, EDS mapping, XPS, and DLS. Mn-MOF showed limited dialyzable Mn leakage, and retained fluorescence stability and MRI signal stability during 28 days of storage. As a T1 MRI contrast platform, Mn-MOF exhibited a longitudinal relaxivity (r1) of 6.38 mM–1 s–1 at 3.0 T and showed OHP-dependent T1 signal attenuation over the tested OHP concentration range of 0.5–10 mM. Preliminary in vivo MRI experiments showed liver and kidney T1 enhancement after intravenous Mn-MOF administration and OHP-associated attenuation of the Mn-MOF-enhanced signal. In fluorescence mode, the Mn-MOF nanosensor exhibited concentration-dependent quenching toward OHP in ultrapure water over 0.33 fM–18.2 μM, with a calibration-model-based estimated limit of detection (LOD) of 41.1 aM under the stated Mn-MOF-assisted fluorescence sensing conditions. The sensor also showed selectivity under the tested interference conditions, spiked-rabbit-serum calibration and recovery performance, and 28-day fluorescence response stability. Hemolysis, H&E staining, KGN and HK-2 cell-viability assays indicated preliminary hemocompatibility and cytocompatibility under the tested conditions. This dual-modal design provides a preliminary strategy for integrating optical OHP sensing with MRI readout in a single Mn-MOF platform.
- Open Access
- 16 August 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (36) , 26604-26610
Enhancement of acidic hydrogen evolution reaction efficiency through Cu/Ni-doped MFI-type protozeolite layered nanoclusters
Electrochemical activation improves amorphous catalyst performance. Activation regulates the Cu oxidation state, improving hydrogen evolution performance. Cu 2+1 O plays a crucial role in improving the catalysts' stability.
- 16 August 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (36) , 26604-26610
Open AccessEnhancement of acidic hydrogen evolution reaction efficiency through Cu/Ni-doped MFI-type protozeolite layered nanoclusters
Electrochemical activation improves amorphous catalyst performance. Activation regulates the Cu oxidation state, improving hydrogen evolution performance. Cu 2+1 O plays a crucial role in improving the catalysts' stability.
- 9 October 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1281, 341891
Highly dispersed redox antimony oxide pairs for accurate detection and electrochemistry-controlled recovery toward an antibiotic drug: Sulfadiazine
- 9 October 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1281, 341891
Highly dispersed redox antimony oxide pairs for accurate detection and electrochemistry-controlled recovery toward an antibiotic drug: Sulfadiazine
- 23 August 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 239, 115631
Trace identification of cysteine enantiomers based on an electrochemical sensor assembled from CuxS@SOD zeolite
- 23 August 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 239, 115631
Trace identification of cysteine enantiomers based on an electrochemical sensor assembled from CuxS@SOD zeolite
- 18 February 2023
- Published by Springer Nature in Microchimica Acta
- Vol. 190 (3) , 1-12
Highly dispersed Cu and Ni nano cluster sensor for ultrasensitive electrochemical detection of antiviral drug lamivudine
The accurate and rapid detection for the nucleoside reverse transcriptase inhibitor lamivudine (LAM, 3TC) in cellular systems is always a challenge in the clinic application. Here, a sensitive Cu and Ni nano cluster sensor for LAM is generated under hydrothermal conditions.The Cu and Ni atoms are highly dispersed and aggregated in the nanosized opening pore windows of the synthesized LTA zeolite, through the diatomic synergistic contribution of Cu and Ni and the enrichment of zeolitic channel pores. Using differential pulse voltammetry (DPV), the detection limit (LOD) of LAM at the potential (− 0.15 V) can reach 0.001 pM and the linear range is 0.002 pM–0.002 μM. Since the nano cluster is separated and restricted by the nanosized windows of the zeolite framework, the sensor provides high stability, good recovery (92.5–109%) and RSD (0.8–3.2%) in the analysis of tap water, RPMI 1640 medium, and rabbit serum. The Cu/Ni/LTA zeolite-modified glassy carbon electrode (Cu/Ni/LTA/GCE) exhibits excellent catalytic performance for LAM with high selectivity over potentially interfering agents. Graphical abstract A sensitive Cu and Ni nano cluster sensor for LAM is generated in the hydrothermal condition that the Cu and Ni atoms are highly dispersed and aggregated in the nanosized opening pore windows of the as-synthesized LTA zeolite. Through the diatomic synergistic contribution of Cu and Ni and the enrichment of zeolitic channel pores, the observed limit of detection (LOD) can reach 0.001 pM under differential pulse voltammetry (DPV) method with a wide linear relationship to 0.002 μM
- 18 February 2023
- Published by Springer Nature in Microchimica Acta
- Vol. 190 (3) , 1-12
Highly dispersed Cu and Ni nano cluster sensor for ultrasensitive electrochemical detection of antiviral drug lamivudine
The accurate and rapid detection for the nucleoside reverse transcriptase inhibitor lamivudine (LAM, 3TC) in cellular systems is always a challenge in the clinic application. Here, a sensitive Cu and Ni nano cluster sensor for LAM is generated under hydrothermal conditions.The Cu and Ni atoms are highly dispersed and aggregated in the nanosized opening pore windows of the synthesized LTA zeolite, through the diatomic synergistic contribution of Cu and Ni and the enrichment of zeolitic channel pores. Using differential pulse voltammetry (DPV), the detection limit (LOD) of LAM at the potential (− 0.15 V) can reach 0.001 pM and the linear range is 0.002 pM–0.002 μM. Since the nano cluster is separated and restricted by the nanosized windows of the zeolite framework, the sensor provides high stability, good recovery (92.5–109%) and RSD (0.8–3.2%) in the analysis of tap water, RPMI 1640 medium, and rabbit serum. The Cu/Ni/LTA zeolite-modified glassy carbon electrode (Cu/Ni/LTA/GCE) exhibits excellent catalytic performance for LAM with high selectivity over potentially interfering agents. Graphical abstract A sensitive Cu and Ni nano cluster sensor for LAM is generated in the hydrothermal condition that the Cu and Ni atoms are highly dispersed and aggregated in the nanosized opening pore windows of the as-synthesized LTA zeolite. Through the diatomic synergistic contribution of Cu and Ni and the enrichment of zeolitic channel pores, the observed limit of detection (LOD) can reach 0.001 pM under differential pulse voltammetry (DPV) method with a wide linear relationship to 0.002 μM