Abu Zaharin Ahmad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Abu Zaharin Ahmad has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- A. M. A. Khalid
Faculty of Electrical & Electronics Engineering, University of Malaysia Pahang, 26600 Pekan, Malaysia
1 shared publication - Abibaker A. Albishti
Higher Institute of Sciences and Technology
1 shared publication - Ekhlas Mhawi Thajeel
Electrical Engineering Dept., University of Technology-Iraq, Alsinaa street, 10066 Baghdad, Iraq
1 shared publication - Elhadi. E. Aker
Higher Institute of Sciences and Technology
1 shared publication Erliza Serri
Sustainable Energy & Power Electronics Research (SuPER), Group, Faculty of Electrical & Electronics Engineering, University Malaysia Pahang, Pekan, Pahang, Malaysia
1 shared publication- Guangping Li
Intelligent Manufacturing College, Nanning University, Nanning, Guangxi, China
1 shared publication
Latest Publications
- Open Access
- 24 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1798-1803
Virtual Simulation of Quadrotor UAV Empowering the Teaching Reform of Automatic Control Principles: Practical Path and Effectiveness Verification
- 24 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1798-1803
Open AccessVirtual Simulation of Quadrotor UAV Empowering the Teaching Reform of Automatic Control Principles: Practical Path and Effectiveness Verification
- Open Access
- 1 September 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (3) , 1478-1489
A neural network controller and a simple circuit of SVPWM technique to increase five-level VSC STATCOM performance during voltage sag and swell
The most critical disturbance faced in the electrical distribution systems is power service interruptions due to voltage sag or swell which results in economic losses on the user’s side. To compensate voltage sag or swell, advanced custom power devices are used and one of such devices is the static synchronous compensation (STATCOM). This paper presents the implementation of 5-level voltage source converter (VSC) STATCOM using a neural network (NN) and a simplified space vector pulse width modulation (SVPWM) circuit. The primary objective of the NN controller and SVPWM circuit is to enhance the performance and response time of the STATCOM system, specifically in terms of improving voltage and power factor (PF) when faced with voltage sag or swell. The performance of STATCOM was examined within the context of the IEEE 3-bus system. The investigation focused on two scenarios: a single-line-to-ground fault resulting in voltage sag, and the sudden connection of a capacitive load leading to voltage swell. The findings unequivocally demonstrated the efficacy of the STATCOM with a NN controller in comparison to a conventional controller. The utilization of the NN controller resulted in notable improvements in voltage and PF within a remarkably short time frame of 0.02 seconds.
- 1 September 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (3) , 1478-1489
Open AccessA neural network controller and a simple circuit of SVPWM technique to increase five-level VSC STATCOM performance during voltage sag and swell
The most critical disturbance faced in the electrical distribution systems is power service interruptions due to voltage sag or swell which results in economic losses on the user’s side. To compensate voltage sag or swell, advanced custom power devices are used and one of such devices is the static synchronous compensation (STATCOM). This paper presents the implementation of 5-level voltage source converter (VSC) STATCOM using a neural network (NN) and a simplified space vector pulse width modulation (SVPWM) circuit. The primary objective of the NN controller and SVPWM circuit is to enhance the performance and response time of the STATCOM system, specifically in terms of improving voltage and power factor (PF) when faced with voltage sag or swell. The performance of STATCOM was examined within the context of the IEEE 3-bus system. The investigation focused on two scenarios: a single-line-to-ground fault resulting in voltage sag, and the sudden connection of a capacitive load leading to voltage swell. The findings unequivocally demonstrated the efficacy of the STATCOM with a NN controller in comparison to a conventional controller. The utilization of the NN controller resulted in notable improvements in voltage and PF within a remarkably short time frame of 0.02 seconds.
- 15 August 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 96
Utilizing the Kolmogorov-Arnold Networks for chiller energy consumption prediction in commercial building
- 15 August 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 96
Utilizing the Kolmogorov-Arnold Networks for chiller energy consumption prediction in commercial building
- Open Access
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Simulation of adaptive gain control via 2-D lookup table for isolated hybrid micro-grid system
This paper presented a smartness 2-D lookup table (2-DLT) control by means of adaptation gain to develop a frequency controller and facilitate the power-sharing requirements in an isolated micro-grid system. This intelligence of an expert controller adopts the scale of adaptation gain for estimating control design. Synchronous power generators are commonly used to provide power to distant and isolated regions where grid expansion is expensive due to economic and technical constraints. Load frequency control (LFC) technology challenges to guarantee the reliability and stability regarding the system. It is known that conventional control methods are unreliable due to frequency variation and sudden changes in the load or failure generation. Traditional control and criteria may not be appropriate for the new structural networks, such as micro-grid. In this work, the performance of the proposed 2-DLT controller is examined and compared to the classical proportional integral (PI) controller and artificial neural network (ANN). The simulation system is implemented and tested using MATLAB/Simulink.
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Open AccessSimulation of adaptive gain control via 2-D lookup table for isolated hybrid micro-grid system
This paper presented a smartness 2-D lookup table (2-DLT) control by means of adaptation gain to develop a frequency controller and facilitate the power-sharing requirements in an isolated micro-grid system. This intelligence of an expert controller adopts the scale of adaptation gain for estimating control design. Synchronous power generators are commonly used to provide power to distant and isolated regions where grid expansion is expensive due to economic and technical constraints. Load frequency control (LFC) technology challenges to guarantee the reliability and stability regarding the system. It is known that conventional control methods are unreliable due to frequency variation and sudden changes in the load or failure generation. Traditional control and criteria may not be appropriate for the new structural networks, such as micro-grid. In this work, the performance of the proposed 2-DLT controller is examined and compared to the classical proportional integral (PI) controller and artificial neural network (ANN). The simulation system is implemented and tested using MATLAB/Simulink.
- Open Access
- 6 May 2022
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2022, 1-12
Low Voltage Ride through Enhancement Using Grey Wolf Optimizer to Reduce Overshoot Current in the Grid-Connected PV System
In today’s world, the DG should not be disconnected in the event of a power outage but should instead remain linked to the grid and supported by reactive power. This can be accomplished by implementing the low voltage ride through (LVRT) with a proportional integral (PI) controller. As a result, the voltage profile can be enhanced. The PI controller, on the other hand, has drawbacks in that setting the gain takes a long time and results in an overshoot current on the grid, which could trigger the protection relay. To address this issue, this paper proposes employing a grey-wolf optimizer (GWO) to enhance the LVRT in a 5 MW three-phase grid-connected PV system. A MATLAB simulation was carried out then under a three-phase fault and load disturbance to verify the efficiency. It is found that, even with a 70% voltage sag, the PV system can remain connected to the electrical grid while minimising overshoot current on the grid side.
- 6 May 2022
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2022, 1-12
Open AccessLow Voltage Ride through Enhancement Using Grey Wolf Optimizer to Reduce Overshoot Current in the Grid-Connected PV System
In today’s world, the DG should not be disconnected in the event of a power outage but should instead remain linked to the grid and supported by reactive power. This can be accomplished by implementing the low voltage ride through (LVRT) with a proportional integral (PI) controller. As a result, the voltage profile can be enhanced. The PI controller, on the other hand, has drawbacks in that setting the gain takes a long time and results in an overshoot current on the grid, which could trigger the protection relay. To address this issue, this paper proposes employing a grey-wolf optimizer (GWO) to enhance the LVRT in a 5 MW three-phase grid-connected PV system. A MATLAB simulation was carried out then under a three-phase fault and load disturbance to verify the efficiency. It is found that, even with a 70% voltage sag, the PV system can remain connected to the electrical grid while minimising overshoot current on the grid side.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 219-224
Comparative study of short prediction MPC-KF with PI controller for DC-DC buck converter
In nature, the DC-DC converter deals with high switching phenomenon that contributes to the higher conduction losses. Its operation conventionally associated with PI/PID controller in order to meet the desired output. To increase the DC-DC converter performance, an advanced controller has been proposed. However, it is deals with complex algorithm that made the controller cost higher. In this paper, the short prediction horizon of MPC using search tree optimization that generates low switching phenomenon is proposed. The optimal problem is being solve using on-line to reduce the computational effort. The Kalman filter is then used for load estimation. This control approach for DC-DC converter has produced the promising output transient performance when compared with conventional PI controller while also minimizing the switching losses phenomenon.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 219-224
Comparative study of short prediction MPC-KF with PI controller for DC-DC buck converter
In nature, the DC-DC converter deals with high switching phenomenon that contributes to the higher conduction losses. Its operation conventionally associated with PI/PID controller in order to meet the desired output. To increase the DC-DC converter performance, an advanced controller has been proposed. However, it is deals with complex algorithm that made the controller cost higher. In this paper, the short prediction horizon of MPC using search tree optimization that generates low switching phenomenon is proposed. The optimal problem is being solve using on-line to reduce the computational effort. The Kalman filter is then used for load estimation. This control approach for DC-DC converter has produced the promising output transient performance when compared with conventional PI controller while also minimizing the switching losses phenomenon.
- Open Access
- 1 January 2010
- Published by Taylor & Francis in SICE Journal of Control, Measurement, and System Integration
- Vol. 3 (1) , 35-42
A New Model Predictive Control Approach to DC-DC Converter Based on Combinatory Optimization
- 1 January 2010
- Published by Taylor & Francis in SICE Journal of Control, Measurement, and System Integration
- Vol. 3 (1) , 35-42
Open AccessA New Model Predictive Control Approach to DC-DC Converter Based on Combinatory Optimization