Deqian Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Deqian Zheng has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Guixiang Chen
School of Civil Engineering, Henan University of Technology, Zhengzhou 450001, China
9 shared publications - Chaosai Liu
College of Civil Engineering, Henan University of Technology, Zhengzhou 450001, China
8 shared publications Guixiang Chen
College of Civil Engineering, Henan University of Technology, Zhengzhou, China
5 shared publications- Wenlei Liu
College of Civil Engineering, Henan University of Technology, Zhengzhou 450001, China
4 shared publications - Wenyong Ma
Shijiazhuang Tiedao Univ
4 shared publications Chaosai Liu
College of Civil Engineering, Henan University of Technology, Zhengzhou, China
2 shared publications
Latest Publications
- Open Access
- 24 November 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (23) , 11653
Effect of Ventilation Ducts on Coupled Heat and Moisture Transfer in Pilot Silo Wheat Bulks with Non-Uniform Porosity
Appropriate ventilation strategies are beneficial for preventing grain deterioration and losses during storage, thereby ensuring grain quality and safety. Using established porous media transport equations, the Ergun equation, and a thin-layer drying model, a coupled heat and moisture transfer framework accounting for non-uniform porosity was implemented and validated for a pilot-scale wheat silo. The engineering comparison examined four, six, and eight vertical branch ducts at a central duct height of 0.94 times the grain filling height, and central duct heights of 0.47 (0.47H), 0.94 (0.94H), and 1.07 (1.07H) times the grain filling height with four branch ducts. At a fixed total inlet mass flow rate of 0.51 kg/s, four branch ducts produced slightly faster initial cooling, while differences among the branch duct configurations diminished during approximately 40–88 h. Central duct height affected the location and extent of residual high-temperature zones, whose area ratios were described by case-specific exponential fits over the simulated ventilation interval. Among the three central duct heights examined, 1.07H produced the smallest high-temperature-zone area ratio at 88 h, whereas 0.94H produced the lowest predicted final moisture content. In the pilot silo and operating conditions of this study, the central air collecting duct positioned near or above the grain surface is beneficial for regulating the ventilation performance of the grain bulk.
- 24 November 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (23) , 11653
Open AccessEffect of Ventilation Ducts on Coupled Heat and Moisture Transfer in Pilot Silo Wheat Bulks with Non-Uniform Porosity
Appropriate ventilation strategies are beneficial for preventing grain deterioration and losses during storage, thereby ensuring grain quality and safety. Using established porous media transport equations, the Ergun equation, and a thin-layer drying model, a coupled heat and moisture transfer framework accounting for non-uniform porosity was implemented and validated for a pilot-scale wheat silo. The engineering comparison examined four, six, and eight vertical branch ducts at a central duct height of 0.94 times the grain filling height, and central duct heights of 0.47 (0.47H), 0.94 (0.94H), and 1.07 (1.07H) times the grain filling height with four branch ducts. At a fixed total inlet mass flow rate of 0.51 kg/s, four branch ducts produced slightly faster initial cooling, while differences among the branch duct configurations diminished during approximately 40–88 h. Central duct height affected the location and extent of residual high-temperature zones, whose area ratios were described by case-specific exponential fits over the simulated ventilation interval. Among the three central duct heights examined, 1.07H produced the smallest high-temperature-zone area ratio at 88 h, whereas 0.94H produced the lowest predicted final moisture content. In the pilot silo and operating conditions of this study, the central air collecting duct positioned near or above the grain surface is beneficial for regulating the ventilation performance of the grain bulk.
- Open Access
- 22 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7356
A Modified Inflow Turbulence Synthesis Method for Large Eddy Simulation: Application to Thermal Stratification Effects on Wind Loads of an Isolated Cubic Building
The variation in thermal stratifications significantly alter the distribution of the wind load on buildings. In this study, large eddy simulation (LES) was adopted to investigate this influence on an isolated cubic building. The thermally stratified turbulent inflow for LES was synthesized by a modified generation method, which combines equilibrium boundary conditions with empirical stability functions and integrates them into the Fluent inherent vortex method. The effectiveness of the present method was verified by comparison with corresponding wind tunnel test data under neutral stratification. The simulated wind load around an isolated cubic building was then compared across three thermal stratification conditions, including neutral, stable and unstable stratification. Compared with the neutral stratification, variations in temperature result in variations in the position and morphology of the horseshoe vortex location at the windward side and separation vortex at the top under stable and unstable stratifications, changing the distribution characteristics of wind pressure in those areas. On the leeward side, the wind pressure and its non-Gaussian characteristics under stable and unstable stratifications are enhanced due the variation in temperature. The extreme wind pressure coefficient at the bottom region of the leeward surfaces under the stable and unstable stratification increases by 1.38- and 1.50-fold, respectively.
- 22 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7356
Open AccessA Modified Inflow Turbulence Synthesis Method for Large Eddy Simulation: Application to Thermal Stratification Effects on Wind Loads of an Isolated Cubic Building
The variation in thermal stratifications significantly alter the distribution of the wind load on buildings. In this study, large eddy simulation (LES) was adopted to investigate this influence on an isolated cubic building. The thermally stratified turbulent inflow for LES was synthesized by a modified generation method, which combines equilibrium boundary conditions with empirical stability functions and integrates them into the Fluent inherent vortex method. The effectiveness of the present method was verified by comparison with corresponding wind tunnel test data under neutral stratification. The simulated wind load around an isolated cubic building was then compared across three thermal stratification conditions, including neutral, stable and unstable stratification. Compared with the neutral stratification, variations in temperature result in variations in the position and morphology of the horseshoe vortex location at the windward side and separation vortex at the top under stable and unstable stratifications, changing the distribution characteristics of wind pressure in those areas. On the leeward side, the wind pressure and its non-Gaussian characteristics under stable and unstable stratifications are enhanced due the variation in temperature. The extreme wind pressure coefficient at the bottom region of the leeward surfaces under the stable and unstable stratification increases by 1.38- and 1.50-fold, respectively.
- 1 July 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (7)
Study of thermal stratification effects on wind fields over a three-dimensional hill using an improved inflow turbulence generation method for large eddy simulation
The influence of thermal stratification variations on the wind fields over hills poses greater challenges for the design of wind-sensitive structures in mountainous areas. In this study, large eddy simulation (LES) was performed to study such influence. The thermally stratified turbulent inflow for LES was generated using an enhanced narrowband synthesis random flow generation method, which integrates equilibrium boundary conditions with empirical stability functions and incorporates refinements to the spatial tuning, timescale, and spectral energy correction factors. Its effectiveness was validated through comparison with wind tunnel test data. The simulated wind flow fields around the hill were then compared across three thermal stratification conditions, including neutral, stable, and unstable stratification. Relative to neutral stratification, temperature variations under stable stratification enlarge both the standing vortex on the windward side and the separated vortex on the leeward side. Conversely, under unstable stratification, the area of the standing vortex increases while that of the separated vortex decreases. These changes in the above vortex position and area significantly alter the wind field distribution around the hill. In the wake region, vortex structures under stable stratification are larger in scale with more concentrated turbulence intensity, whereas under unstable stratification, vortex shedding is more pronounced and accompanied by more extensive turbulence dissipation. Furthermore, a wind field prediction model for hilly terrain, developed using the atmospheric stability data and wind field data under neutral stratification, was proposed and demonstrated satisfactory performance under both stable and unstable stratification conditions.
- 1 July 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (7)
Study of thermal stratification effects on wind fields over a three-dimensional hill using an improved inflow turbulence generation method for large eddy simulation
The influence of thermal stratification variations on the wind fields over hills poses greater challenges for the design of wind-sensitive structures in mountainous areas. In this study, large eddy simulation (LES) was performed to study such influence. The thermally stratified turbulent inflow for LES was generated using an enhanced narrowband synthesis random flow generation method, which integrates equilibrium boundary conditions with empirical stability functions and incorporates refinements to the spatial tuning, timescale, and spectral energy correction factors. Its effectiveness was validated through comparison with wind tunnel test data. The simulated wind flow fields around the hill were then compared across three thermal stratification conditions, including neutral, stable, and unstable stratification. Relative to neutral stratification, temperature variations under stable stratification enlarge both the standing vortex on the windward side and the separated vortex on the leeward side. Conversely, under unstable stratification, the area of the standing vortex increases while that of the separated vortex decreases. These changes in the above vortex position and area significantly alter the wind field distribution around the hill. In the wake region, vortex structures under stable stratification are larger in scale with more concentrated turbulence intensity, whereas under unstable stratification, vortex shedding is more pronounced and accompanied by more extensive turbulence dissipation. Furthermore, a wind field prediction model for hilly terrain, developed using the atmospheric stability data and wind field data under neutral stratification, was proposed and demonstrated satisfactory performance under both stable and unstable stratification conditions.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Driving mechanism of vortex-induced vibration for the Humen Bridge and its mitigation
Vortex-induced vibration (VIV) of the Humen Bridge in 2020 raised a major concern about the application of shallow box girders in long-span bridges since their aerodynamic characteristics are highly sensitive to aerodynamic shape and deck attachments. In this study, large eddy simulation (LES) coupled with computational structural dynamics was first employed to reveal the VIV response of the Humen Bridge under different wind speeds and to investigate the flow structure and driving mechanism during the VIV process. Then, LES was further used to explore aerodynamic measures and their mechanisms to effectively mitigate the VIV of the Humen Bridge. Finally, sectional model wind tunnel tests were carried out to measure the wind pressure on the bridge deck and the wake flow with various deck attachments. The results indicate that, when VIV is observed on the original stiffening girder, pressure fluctuations on the bottom surface are intensified. The strong vortex shedding at the bottom of the stiffening girder is identified as the primary driver of the vertical bending VIV. This phenomenon can be effectively mitigated by moving the side maintenance rail (MR) inward or replacing it with invisible MRs. The upstream barrier and MR on the original stiffening girder obstruct the airflow, inducing strong flow separation. This results in an expansion of high negative pressure zones on both the top and bottom surfaces, generating significant mean and fluctuating aerodynamic forces.
- 1 September 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (9)
Driving mechanism of vortex-induced vibration for the Humen Bridge and its mitigation
Vortex-induced vibration (VIV) of the Humen Bridge in 2020 raised a major concern about the application of shallow box girders in long-span bridges since their aerodynamic characteristics are highly sensitive to aerodynamic shape and deck attachments. In this study, large eddy simulation (LES) coupled with computational structural dynamics was first employed to reveal the VIV response of the Humen Bridge under different wind speeds and to investigate the flow structure and driving mechanism during the VIV process. Then, LES was further used to explore aerodynamic measures and their mechanisms to effectively mitigate the VIV of the Humen Bridge. Finally, sectional model wind tunnel tests were carried out to measure the wind pressure on the bridge deck and the wake flow with various deck attachments. The results indicate that, when VIV is observed on the original stiffening girder, pressure fluctuations on the bottom surface are intensified. The strong vortex shedding at the bottom of the stiffening girder is identified as the primary driver of the vertical bending VIV. This phenomenon can be effectively mitigated by moving the side maintenance rail (MR) inward or replacing it with invisible MRs. The upstream barrier and MR on the original stiffening girder obstruct the airflow, inducing strong flow separation. This results in an expansion of high negative pressure zones on both the top and bottom surfaces, generating significant mean and fluctuating aerodynamic forces.
- Open Access
- 17 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Segregation of particles during maize loading process in a center-loaded silo
Kernel breakage and segregation are unavoidable phenomena during maize loading process in the silo, and the study of this phenomenon is beneficial for solving the aeration, drying and insect control in grain storage. Distribution and segregation of broken kernels, dust, and fragments (BKDF), inorganic impurities, foreign kernels and other organic impurities were studied by maize loading process in a center-loaded silo. Maize was loaded through a vertical funnel into the silo from four drop heights (0.3, 1, 2 and 3.1 m). Samples were collected using a sampling tube inserted vertically at a Y-shaped locations along three radii of the silo for each drop heights. The difference in porosity distribution in the spatial position of the maize bulk caused by kernel breakage and segregation was determined. Higher drop heights increased the content of BKDF, and the BKDF decreased nonlinearly with the increase of distance from the center of the silo. The foreign kernels concentration near the center of the silo was higher than that near the silo wall. Inorganic impurities mainly accumulated in the 1/4–3/4 radius, while other organic impurities accumulated mostly near the wall of the silo. A nonlinear model considering kernel breakage and segregation was developed to predict the porosity distribution in the vertical and radial direction in the silo. Kernel breakage and segregation minimize the porosity at the center of the silo. The porosity of the silo center was 0.421–0.438, and it increased with the distance from the center of the silo increased.
- 17 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Open AccessSegregation of particles during maize loading process in a center-loaded silo
Kernel breakage and segregation are unavoidable phenomena during maize loading process in the silo, and the study of this phenomenon is beneficial for solving the aeration, drying and insect control in grain storage. Distribution and segregation of broken kernels, dust, and fragments (BKDF), inorganic impurities, foreign kernels and other organic impurities were studied by maize loading process in a center-loaded silo. Maize was loaded through a vertical funnel into the silo from four drop heights (0.3, 1, 2 and 3.1 m). Samples were collected using a sampling tube inserted vertically at a Y-shaped locations along three radii of the silo for each drop heights. The difference in porosity distribution in the spatial position of the maize bulk caused by kernel breakage and segregation was determined. Higher drop heights increased the content of BKDF, and the BKDF decreased nonlinearly with the increase of distance from the center of the silo. The foreign kernels concentration near the center of the silo was higher than that near the silo wall. Inorganic impurities mainly accumulated in the 1/4–3/4 radius, while other organic impurities accumulated mostly near the wall of the silo. A nonlinear model considering kernel breakage and segregation was developed to predict the porosity distribution in the vertical and radial direction in the silo. Kernel breakage and segregation minimize the porosity at the center of the silo. The porosity of the silo center was 0.421–0.438, and it increased with the distance from the center of the silo increased.
- Open Access
- 4 February 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (3) , 338
Analysis of Heat and Moisture Transfer and Fungi-Induced Hot Spots in Maize Bulk with Different Broken Kernel Contents
Kernel breakage and fungi-induced hot spots can easily lead to potential safety hazards in maize storage. The objective of this study was to focus on the formation and development of hot spots in maize bulk with two different broken kernels contents (BKCs), i.e., 4.26% (BKC4.26) and 6.14% (BKC6.14), and a moisture content of 16.3% under the same storage conditions. A multifunctional simulation system was developed to simulate the heat and moisture transfer process in stored grain bulk, and a new method was proposed to evaluate the effect of local hot spots on the storage safety of maize bulk with different BKCs. The results showed that there are differences in fungal respiration rates in the maize bulk with two different BKCs, and the temperature impact range caused by hot spots under the same storage conditions was different. The maximum temperature caused by fungal growth in BKC4.26 and BKC6.14 was 37.47 °C and 38.81 °C, and the proportion of high-temperature areas caused was 64.2% and 62.3%. The relative humidity at local hot spots continued to decrease, reaching 64.8% and 71.7% when stored for 1800 h in BKC4.26 and BKC6.14. The CO2 concentration at hot spots in BKC6.14 was higher than that of BKC4.26, while the O2 concentration was lower than BKC4.26. Dry matter loss (DML) at the hot spots in BKC6.14 was higher than that in BKC4.26. A nonlinear model was developed to predict temperature changes of fungi-induced hot spots in maize bulk considering the storage time, temperature, relative humidity, and CO2 concentration at the hot spots, and the model fit the experimental data reasonably well.
- 4 February 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (3) , 338
Open AccessAnalysis of Heat and Moisture Transfer and Fungi-Induced Hot Spots in Maize Bulk with Different Broken Kernel Contents
Kernel breakage and fungi-induced hot spots can easily lead to potential safety hazards in maize storage. The objective of this study was to focus on the formation and development of hot spots in maize bulk with two different broken kernels contents (BKCs), i.e., 4.26% (BKC4.26) and 6.14% (BKC6.14), and a moisture content of 16.3% under the same storage conditions. A multifunctional simulation system was developed to simulate the heat and moisture transfer process in stored grain bulk, and a new method was proposed to evaluate the effect of local hot spots on the storage safety of maize bulk with different BKCs. The results showed that there are differences in fungal respiration rates in the maize bulk with two different BKCs, and the temperature impact range caused by hot spots under the same storage conditions was different. The maximum temperature caused by fungal growth in BKC4.26 and BKC6.14 was 37.47 °C and 38.81 °C, and the proportion of high-temperature areas caused was 64.2% and 62.3%. The relative humidity at local hot spots continued to decrease, reaching 64.8% and 71.7% when stored for 1800 h in BKC4.26 and BKC6.14. The CO2 concentration at hot spots in BKC6.14 was higher than that of BKC4.26, while the O2 concentration was lower than BKC4.26. Dry matter loss (DML) at the hot spots in BKC6.14 was higher than that in BKC4.26. A nonlinear model was developed to predict temperature changes of fungi-induced hot spots in maize bulk considering the storage time, temperature, relative humidity, and CO2 concentration at the hot spots, and the model fit the experimental data reasonably well.
- Open Access
- 22 December 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (12) , 1540
Large Eddy Simulation of Flow Around Twin Tower Buildings in Tandem Arrangements with Upstream Corner Modification
The aerodynamic performance of twin tall buildings immersed in the atmospheric boundary layer was numerically investigated by adopting the spatial-averaged large eddy simulation (LES) method. This study focused on the effects of corner cutting and chamfering. The buildings were both square and sectional with a width-to-height ratio of 1:6, and were arranged in a tandem configuration with a spacing ratio of 2.0. The corner-cutting and chamfering measures were only applied to the upstream cylinder, with a corner modification rate of 10%. To generate the turbulent inflow boundary condition (IBC) for LES, steady-state equilibrium IBC expressions were introduced into the vortex method, which were implemented in the commercial code Ansys Fluent. The present simulation method and solution parameters were first verified by comparing the simulated wind field and the wind pressure distribution on a single tall building with those of the wind tunnel test. The influences of the corner-cutting and chamfering measures on the wind load of the tandem buildings were then comparatively studied concerning the statistical values of their aerodynamic force coefficients and wind pressure coefficients. The influence mechanism was analyzed based on the simulated time-averaged flow field and the instantaneous vortex structure around the buildings. The results indicated that upstream corner-cutting and chamfering measures can induce a diffusion angle shift in the separated shear flow from the leading edge of the upstream building, thus affecting the separation and reattachment of the separated upstream flow on the downstream building. Among the measures studied, upstream corner cutting is more effective in reducing wind pressure and aerodynamic force coefficients.
- 22 December 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (12) , 1540
Open AccessLarge Eddy Simulation of Flow Around Twin Tower Buildings in Tandem Arrangements with Upstream Corner Modification
The aerodynamic performance of twin tall buildings immersed in the atmospheric boundary layer was numerically investigated by adopting the spatial-averaged large eddy simulation (LES) method. This study focused on the effects of corner cutting and chamfering. The buildings were both square and sectional with a width-to-height ratio of 1:6, and were arranged in a tandem configuration with a spacing ratio of 2.0. The corner-cutting and chamfering measures were only applied to the upstream cylinder, with a corner modification rate of 10%. To generate the turbulent inflow boundary condition (IBC) for LES, steady-state equilibrium IBC expressions were introduced into the vortex method, which were implemented in the commercial code Ansys Fluent. The present simulation method and solution parameters were first verified by comparing the simulated wind field and the wind pressure distribution on a single tall building with those of the wind tunnel test. The influences of the corner-cutting and chamfering measures on the wind load of the tandem buildings were then comparatively studied concerning the statistical values of their aerodynamic force coefficients and wind pressure coefficients. The influence mechanism was analyzed based on the simulated time-averaged flow field and the instantaneous vortex structure around the buildings. The results indicated that upstream corner-cutting and chamfering measures can induce a diffusion angle shift in the separated shear flow from the leading edge of the upstream building, thus affecting the separation and reattachment of the separated upstream flow on the downstream building. Among the measures studied, upstream corner cutting is more effective in reducing wind pressure and aerodynamic force coefficients.
- 17 October 2024
- Published by Elsevier in Journal of Hydrology
- Vol. 645
Research on methodology for assessing social vulnerability to urban flooding: A case study in China
- 17 October 2024
- Published by Elsevier in Journal of Hydrology
- Vol. 645
Research on methodology for assessing social vulnerability to urban flooding: A case study in China
- 16 October 2024
- Published by Elsevier in Journal of Hydrology
- Vol. 645
Analyzing the spatial scale effects of urban elements on urban flooding based on multiscale geographically weighted regression
- 16 October 2024
- Published by Elsevier in Journal of Hydrology
- Vol. 645
Analyzing the spatial scale effects of urban elements on urban flooding based on multiscale geographically weighted regression
- 1 July 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (7)
Numerical investigation of cylinder rotors with various endplates
For a finite-length cylinder rotor, rotation induces unique pattern tip vortices at the free end, significantly altering the aerodynamic characteristics of the rotor. Endplates are often applied to finite-length cylinders as a means of restraining end effects. The endplates change the aerodynamic characteristics of the rotor by affecting the end axial flow. In the present study, cylinder rotors with static and rotating endplates of various diameters are investigated by means of large eddy simulation. By analyzing the aerodynamic force, wind pressure, and flow field characteristics of the rotors, the varying patterns and reasons for the aerodynamic characteristics of rotors with static and rotating endplates are clarified. The results show that the endplate induces disk vortices and changes the vortex patterns at the free end of the rotor, and the static endplates show little effect on the development of tip vortices, so the wake vortices show the triple vortex pattern, whereas the rotating endplates enhance the intensity of the plate vortices and inhibit the tip vortices development, leading to the double vortex pattern, which in turn produces a different pattern of aerodynamic characteristics compared to the rotor with the static endplates. The mechanism of the variation in the aerodynamic characteristics and vortex patterns is partially explained by analyzing and discussing the flow field results.
- 1 July 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (7)
Numerical investigation of cylinder rotors with various endplates
For a finite-length cylinder rotor, rotation induces unique pattern tip vortices at the free end, significantly altering the aerodynamic characteristics of the rotor. Endplates are often applied to finite-length cylinders as a means of restraining end effects. The endplates change the aerodynamic characteristics of the rotor by affecting the end axial flow. In the present study, cylinder rotors with static and rotating endplates of various diameters are investigated by means of large eddy simulation. By analyzing the aerodynamic force, wind pressure, and flow field characteristics of the rotors, the varying patterns and reasons for the aerodynamic characteristics of rotors with static and rotating endplates are clarified. The results show that the endplate induces disk vortices and changes the vortex patterns at the free end of the rotor, and the static endplates show little effect on the development of tip vortices, so the wake vortices show the triple vortex pattern, whereas the rotating endplates enhance the intensity of the plate vortices and inhibit the tip vortices development, leading to the double vortex pattern, which in turn produces a different pattern of aerodynamic characteristics compared to the rotor with the static endplates. The mechanism of the variation in the aerodynamic characteristics and vortex patterns is partially explained by analyzing and discussing the flow field results.