Luisa Huck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Luisa Huck has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Christiane Katharina Kuhl
Department of Diagnostic and Interventional Radiology University Hospital RWTH Aachen Aachen Germany
4 shared publications - Daniel Truhn
Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany
3 shared publications - Firas Khader
University Hospital Aachen
3 shared publications - Gustav Müller-Franzes
Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany
3 shared publications - Jakob Nikolas Kather
Else Kroener Fresenius Center for Digital Health, Technical University Dresden, Dresden, Germany
3 shared publications - Sven Nebelung
Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany
3 shared publications
Latest Publications
- 1 May 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 315 (2) , e241371
Intraindividual Comparison of Ultrafast versus Standard Two-dimensional Dynamic Contrast-enhanced Breast MRI
In women with background parenchymal enhancement or difficult-to-characterize enhancing lesions at standard two-dimensional dynamic contrast-enhanced breast MRI who underwent ultrafast MRI as a second contrast-enhanced examination, ultrafast imaging reduced lesion conspicuity and did not improve lesion classification.
- 1 May 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 315 (2) , e241371
Intraindividual Comparison of Ultrafast versus Standard Two-dimensional Dynamic Contrast-enhanced Breast MRI
In women with background parenchymal enhancement or difficult-to-characterize enhancing lesions at standard two-dimensional dynamic contrast-enhanced breast MRI who underwent ultrafast MRI as a second contrast-enhanced examination, ultrafast imaging reduced lesion conspicuity and did not improve lesion classification.
- 1 July 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 312 (1) , e232304
Intraindividual Comparison of Different Methods for Automated BPE Assessment at Breast MRI: A Call for Standardization
Substantial heterogeneity was observed between different background parenchymal enhancement categorization methods; methods that consider enhancement intensity were more closely correlated to experienced radiologists’ visual analysis than methods that consider enhancing volume.
- 1 July 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 312 (1) , e232304
Intraindividual Comparison of Different Methods for Automated BPE Assessment at Breast MRI: A Call for Standardization
Substantial heterogeneity was observed between different background parenchymal enhancement categorization methods; methods that consider enhancement intensity were more closely correlated to experienced radiologists’ visual analysis than methods that consider enhancing volume.
- 27 June 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (12) , 838-844
Dedicated Photon-Counting CT for Detection and Classification of Microcalcifications
Objectives: Clinical experience regarding the use of dedicated photon-counting breast CT (PC-BCT) for diagnosis of breast microcalcifications is scarce. This study systematically compares the detection and classification of breast microcalcifications using a dedicated breast photon-counting CT, especially designed for examining the breast, in comparison with digital breast tomosynthesis (DBT). Materials and Methods: This is a prospective intraindividual study on women with DBT screening–detected BI-RADS-4/-5 microcalcifications who underwent PC-BCT before biopsy. PC-BCT images were reconstructed with a noninterpolated spatial resolution of 0.15 × 0.15 × 0.15 mm (reconstruction mode 1 [RM-1]) and with 0.3 × 0.3 × 0.3 mm (reconstruction mode 2 [RM-2]), plus thin-slab maximum intensity projection (MIP) reconstructions. Two radiologists independently rated the detection of microcalcifications in direct comparison with DBT on a 5-point scale. The distribution and morphology of microcalcifications were then rated according to BI-RADS. The size of the smallest discernible microcalcification particle was measured. For PC-BCT, the average glandular dose was determined by Monte Carlo simulations; for DBT, the information provided by the DBT system was used. Results: Between September 2022 and July 2023, 22 participants (mean age, 61; range, 42–85 years) with microcalcifications (16 malignant; 6 benign) were included. In 2/22 with microcalcifications in the posterior region, microcalcifications were not detectable on PC-BCT, likely because they were not included in the PC-BCT volume. In the remaining 20 participants, microcalcifications were detectable. With high between-reader agreement (κ > 0.8), conspicuity of microcalcifications was rated similar for DBT and MIPs of RM-1 (mean, 4.83 ± 0.38 vs 4.86 ± 0.35) (P = 0.66), but was significantly lower (P < 0.05) for the remaining PC-BCT reconstructions: 2.11 ± 0.92 (RM-2), 2.64 ± 0.80 (MIPs of RM-2), and 3.50 ± 1.23 (RM-1). Identical distribution qualifiers were assigned for PC-BCT and DBT in 18/20 participants, with excellent agreement (κ = 0.91), whereas identical morphologic qualifiers were assigned in only 5/20, with poor agreement (κ = 0.44). The median size of smallest discernible microcalcification particle was 0.2 versus 0.6 versus 1.1 mm in DBT versus RM-1 versus RM-2 (P < 0.001), likely due to blooming effects. Average glandular dose was 7.04 mGy (PC-BCT) versus 6.88 mGy (DBT) (P = 0.67). Conclusions: PC-BCT allows reliable detection of in-breast microcalcifications as long as they are not located in the posterior part of the breast and allows assessment of their distribution, but not of their individual morphology.
- 27 June 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (12) , 838-844
Dedicated Photon-Counting CT for Detection and Classification of Microcalcifications
Objectives: Clinical experience regarding the use of dedicated photon-counting breast CT (PC-BCT) for diagnosis of breast microcalcifications is scarce. This study systematically compares the detection and classification of breast microcalcifications using a dedicated breast photon-counting CT, especially designed for examining the breast, in comparison with digital breast tomosynthesis (DBT). Materials and Methods: This is a prospective intraindividual study on women with DBT screening–detected BI-RADS-4/-5 microcalcifications who underwent PC-BCT before biopsy. PC-BCT images were reconstructed with a noninterpolated spatial resolution of 0.15 × 0.15 × 0.15 mm (reconstruction mode 1 [RM-1]) and with 0.3 × 0.3 × 0.3 mm (reconstruction mode 2 [RM-2]), plus thin-slab maximum intensity projection (MIP) reconstructions. Two radiologists independently rated the detection of microcalcifications in direct comparison with DBT on a 5-point scale. The distribution and morphology of microcalcifications were then rated according to BI-RADS. The size of the smallest discernible microcalcification particle was measured. For PC-BCT, the average glandular dose was determined by Monte Carlo simulations; for DBT, the information provided by the DBT system was used. Results: Between September 2022 and July 2023, 22 participants (mean age, 61; range, 42–85 years) with microcalcifications (16 malignant; 6 benign) were included. In 2/22 with microcalcifications in the posterior region, microcalcifications were not detectable on PC-BCT, likely because they were not included in the PC-BCT volume. In the remaining 20 participants, microcalcifications were detectable. With high between-reader agreement (κ > 0.8), conspicuity of microcalcifications was rated similar for DBT and MIPs of RM-1 (mean, 4.83 ± 0.38 vs 4.86 ± 0.35) (P = 0.66), but was significantly lower (P < 0.05) for the remaining PC-BCT reconstructions: 2.11 ± 0.92 (RM-2), 2.64 ± 0.80 (MIPs of RM-2), and 3.50 ± 1.23 (RM-1). Identical distribution qualifiers were assigned for PC-BCT and DBT in 18/20 participants, with excellent agreement (κ = 0.91), whereas identical morphologic qualifiers were assigned in only 5/20, with poor agreement (κ = 0.44). The median size of smallest discernible microcalcification particle was 0.2 versus 0.6 versus 1.1 mm in DBT versus RM-1 versus RM-2 (P < 0.001), likely due to blooming effects. Average glandular dose was 7.04 mGy (PC-BCT) versus 6.88 mGy (DBT) (P = 0.67). Conclusions: PC-BCT allows reliable detection of in-breast microcalcifications as long as they are not located in the posterior part of the breast and allows assessment of their distribution, but not of their individual morphology.
- Top Cited Papers
- 1 May 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 307 (3) , e222211
Using Machine Learning to Reduce the Need for Contrast Agents in Breast MRI through Synthetic Images
Background Reducing the amount of contrast agent needed for contrast-enhanced breast MRI is desirable. Purpose To investigate if generative adversarial networks (GANs) can recover contrast-enhanced breast MRI scans from unenhanced images and virtual low-contrast-enhanced images. Materials and Methods In this retrospective study of breast MRI performed from January 2010 to December 2019, simulated low-contrast images were produced by adding virtual noise to the existing contrast-enhanced images. GANs were then trained to recover the contrast-enhanced images from the simulated low-contrast images (approach A) or from the unenhanced T1- and T2-weighted images (approach B). Two experienced radiologists were tasked with distinguishing between real and synthesized contrast-enhanced images using both approaches. Image appearance and conspicuity of enhancing lesions on the real versus synthesized contrast-enhanced images were independently compared and rated on a five-point Likert scale. P values were calculated by using bootstrapping. Results A total of 9751 breast MRI examinations from 5086 patients (mean age, 56 years ± 10 [SD]) were included. Readers who were blinded to the nature of the images could not distinguish real from synthetic contrast-enhanced images (average accuracy of differentiation: approach A, 52 of 100; approach B, 61 of 100). The test set included images with and without enhancing lesions (29 enhancing masses and 21 nonmass enhancement; 50 total). When readers who were not blinded compared the appearance of the real versus synthetic contrast-enhanced images side by side, approach A image ratings were significantly higher than those of approach B (mean rating, 4.6 ± 0.1 vs 3.0 ± 0.2; P < .001), with the noninferiority margin met by synthetic images from approach A (P < .001) but not B (P > .99). Conclusion Generative adversarial networks may be useful to enable breast MRI with reduced contrast agent dose. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bahl in this issue.
- 1 May 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 307 (3) , e222211
Top Cited PapersUsing Machine Learning to Reduce the Need for Contrast Agents in Breast MRI through Synthetic Images
Background Reducing the amount of contrast agent needed for contrast-enhanced breast MRI is desirable. Purpose To investigate if generative adversarial networks (GANs) can recover contrast-enhanced breast MRI scans from unenhanced images and virtual low-contrast-enhanced images. Materials and Methods In this retrospective study of breast MRI performed from January 2010 to December 2019, simulated low-contrast images were produced by adding virtual noise to the existing contrast-enhanced images. GANs were then trained to recover the contrast-enhanced images from the simulated low-contrast images (approach A) or from the unenhanced T1- and T2-weighted images (approach B). Two experienced radiologists were tasked with distinguishing between real and synthesized contrast-enhanced images using both approaches. Image appearance and conspicuity of enhancing lesions on the real versus synthesized contrast-enhanced images were independently compared and rated on a five-point Likert scale. P values were calculated by using bootstrapping. Results A total of 9751 breast MRI examinations from 5086 patients (mean age, 56 years ± 10 [SD]) were included. Readers who were blinded to the nature of the images could not distinguish real from synthetic contrast-enhanced images (average accuracy of differentiation: approach A, 52 of 100; approach B, 61 of 100). The test set included images with and without enhancing lesions (29 enhancing masses and 21 nonmass enhancement; 50 total). When readers who were not blinded compared the appearance of the real versus synthetic contrast-enhanced images side by side, approach A image ratings were significantly higher than those of approach B (mean rating, 4.6 ± 0.1 vs 3.0 ± 0.2; P < .001), with the noninferiority margin met by synthetic images from approach A (P < .001) but not B (P > .99). Conclusion Generative adversarial networks may be useful to enable breast MRI with reduced contrast agent dose. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bahl in this issue.
- 1 April 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 307 (1) , e220510
Artificial Intelligence for Clinical Interpretation of Bedside Chest Radiographs
An artificial intelligence system trained with structured chest radiography reports provided clinically useful support for non-radiologist physicians. Background Supine chest radiography for bedridden patients in intensive care units (ICUs) is one of the most frequently ordered imaging studies worldwide. Purpose To evaluate the diagnostic perform...
- 1 April 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 307 (1) , e220510
Artificial Intelligence for Clinical Interpretation of Bedside Chest Radiographs
An artificial intelligence system trained with structured chest radiography reports provided clinically useful support for non-radiologist physicians. Background Supine chest radiography for bedridden patients in intensive care units (ICUs) is one of the most frequently ordered imaging studies worldwide. Purpose To evaluate the diagnostic perform...
- Open Access
- 7 May 2022
- Published by Springer Nature in European Radiology
- Vol. 32 (11) , 7430-7438
Background parenchymal enhancement in contrast-enhanced MR imaging suggests systemic effects of intrauterine contraceptive devices
Objectives: Levonorgestrel-releasing intrauterine contraceptive devices (LNG-IUDs) are designed to exhibit only local hormonal effects. There is an ongoing debate on whether LNG-IUDs can have side effects similar to systemic hormonal medication. Benign background parenchymal enhancement (BPE) in dynamic contrast–enhanced (DCE) MRI has been established as a sensitive marker of hormonal stimulation of the breast. We investigated the association between LNG-IUD use and BPE in breast MRI to further explore possible systemic effects of LNG-IUDs. Methods: Our hospital database was searched to identify premenopausal women without personal history of breast cancer, oophorectomy, and hormone replacement or antihormone therapy, who had undergone standardized DCE breast MRI at least twice, once with and without an LNG-IUD in place. To avoid confounding aging-related effects on BPE, half of included women had their first MRI without, the other half with, LNG-IUD in place. Degree of BPE was analyzed according to the ACR categories. Wilcoxon-matched-pairs signed-rank test was used to compare the distribution of ACR categories with vs. without LNG-IUD. Results: Forty-eight women (mean age, 46 years) were included. In 24/48 women (50% [95% CI: 35.9–64.1%]), ACR categories did not change with vs. without LNG-IUDs. In 23/48 women (48% [33.9–62.1%]), the ACR category was higher with vs. without LNG-IUDs; in 1/48 (2% [0–6%]), the ACR category was lower with vs. without LNG-IUDs. The change of ACR category depending on the presence or absence of an LNG-IUD proved highly significant (p < 0.001). Conclusion: The use of an LNG-IUD can be associated with increased BPE in breast MRI, providing further evidence that LNG-IUDs do have systemic effects. Key Points: • The use of levonorgestrel-releasing intrauterine contraceptive devices is associated with increased background parenchymal enhancement in breast MRI. • This suggests that hormonal effects of these devices are not only confined to the uterine cavity, but may be systemic. • Potential systemic effects of levonorgestrel-releasing intrauterine contraceptive devices should therefore be considered.
- 7 May 2022
- Published by Springer Nature in European Radiology
- Vol. 32 (11) , 7430-7438
Open AccessBackground parenchymal enhancement in contrast-enhanced MR imaging suggests systemic effects of intrauterine contraceptive devices
Objectives: Levonorgestrel-releasing intrauterine contraceptive devices (LNG-IUDs) are designed to exhibit only local hormonal effects. There is an ongoing debate on whether LNG-IUDs can have side effects similar to systemic hormonal medication. Benign background parenchymal enhancement (BPE) in dynamic contrast–enhanced (DCE) MRI has been established as a sensitive marker of hormonal stimulation of the breast. We investigated the association between LNG-IUD use and BPE in breast MRI to further explore possible systemic effects of LNG-IUDs. Methods: Our hospital database was searched to identify premenopausal women without personal history of breast cancer, oophorectomy, and hormone replacement or antihormone therapy, who had undergone standardized DCE breast MRI at least twice, once with and without an LNG-IUD in place. To avoid confounding aging-related effects on BPE, half of included women had their first MRI without, the other half with, LNG-IUD in place. Degree of BPE was analyzed according to the ACR categories. Wilcoxon-matched-pairs signed-rank test was used to compare the distribution of ACR categories with vs. without LNG-IUD. Results: Forty-eight women (mean age, 46 years) were included. In 24/48 women (50% [95% CI: 35.9–64.1%]), ACR categories did not change with vs. without LNG-IUDs. In 23/48 women (48% [33.9–62.1%]), the ACR category was higher with vs. without LNG-IUDs; in 1/48 (2% [0–6%]), the ACR category was lower with vs. without LNG-IUDs. The change of ACR category depending on the presence or absence of an LNG-IUD proved highly significant (p < 0.001). Conclusion: The use of an LNG-IUD can be associated with increased BPE in breast MRI, providing further evidence that LNG-IUDs do have systemic effects. Key Points: • The use of levonorgestrel-releasing intrauterine contraceptive devices is associated with increased background parenchymal enhancement in breast MRI. • This suggests that hormonal effects of these devices are not only confined to the uterine cavity, but may be systemic. • Potential systemic effects of levonorgestrel-releasing intrauterine contraceptive devices should therefore be considered.