EAEhsan Aalaei

Ehsan Aalaei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ehsan Aalaei has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Immunomechanobiology: Engineering the Activation and Function of Immune Cells With the Mechanical Signal of Fluid Shear Stress

    by N. S. Sarna, N. M. Curry, E. Aalaei, B. G. Kaufman, M. R. King

    Immunomechanobiology, the study of how physical forces influence the behavior and function of immune cells, is a rapidly growing area of research. It is becoming increasingly recognized that mechanical stimuli, such as fluid shear forces, are a critical determinant of immune cell regulation. In this review, we discuss the principles and significance of various mechanical forces present within the human body, with a focus on fluid shear flow and its impact on immune cell activation and function. Moreover, we discuss engineering approaches used to study immune cell mechanobiology, and their implications in health and diseases such as cancer, autoimmune disorders, and infectious disease.


  • Open Access

    Numerical study of the performance of a bubble driven micromixer based on oscillating bubble injection

    by Hossein Safaei Rad, Ehsan Aalaei, Seyed Mostafa Mousavi, Reza Kamali

    Micromixers are one of the common pieces of equipment in microfluidic devices and have been widely used for a variety of applications. They are generally divided into active and passive categories. Active micromixers use external energy sources for mixing. Pressure-based micromixers are a common type of active micromixer that use a variety of strategies to create disturbances in the flow and improve mixing. Of all the strategies used for this type of micromixer, oscillating bubble injection has rarely been investigated. In this study, we investigate the flow characteristics and mass transfer process in a two-dimensional micromixer based on oscillating bubble injection. Different parameters affect the mixing performance in this micromixer. In this study, the effects of Reynolds number, bubble oscillation frequency, bubble oscillation amplitude, and side channel geometry on three variables of mixing index, pressure drop, and air inlet pressure have been investigated. The results show that with increasing Reynolds number at constant bubble oscillation frequency and amplitude, the mixing index decreases. Also, with increasing bubble oscillation frequency at constant Reynolds number and constant oscillation amplitude, the mixing index will increase. Increasing the bubble oscillation amplitude at constant Reynolds number and constant oscillation frequency will increase the mixing index. In a simple side channel with a constant diameter, the bubble becomes unstable, so this geometry is undesirable. Changing the side channel geometry by introducing an expansion in the side channel will solve this problem. Nevertheless, increasing the side channel expansion width will reduce the mixing index. The best mixing index was 78.19% in 4.5 seconds, and it shows that the proposed micromixer of this research has good performance in a relatively short time.

  • Open Access

    Signal-Based Methods in Dielectrophoresis for Cell and Particle Separation

    by Malihe Farasat, Ehsan Aalaei, Saeed Kheirati Ronizi, Atin Bakhshi, Shaghayegh Mirhosseini, Jun Zhang, Nam-Trung Nguyen, Navid Kashaninejad

    Separation and detection of cells and particles in a suspension are essential for various applications, including biomedical investigations and clinical diagnostics. Microfluidics realizes the miniaturization of analytical devices by controlling the motion of a small volume of fluids in microchannels and microchambers. Accordingly, microfluidic devices have been widely used in particle/cell manipulation processes. Different microfluidic methods for particle separation include dielectrophoretic, magnetic, optical, acoustic, hydrodynamic, and chemical techniques. Dielectrophoresis (DEP) is a method for manipulating polarizable particles’ trajectories in non-uniform electric fields using unique dielectric characteristics. It provides several advantages for dealing with neutral bioparticles owing to its sensitivity, selectivity, and noninvasive nature. This review provides a detailed study on the signal-based DEP methods that use the applied signal parameters, including frequency, amplitude, phase, and shape for cell/particle separation and manipulation. Rather than employing complex channels or time-consuming fabrication procedures, these methods realize sorting and detecting the cells/particles by modifying the signal parameters while using a relatively simple device. In addition, these methods can significantly impact clinical diagnostics by making low-cost and rapid separation possible. We conclude the review by discussing the technical and biological challenges of DEP techniques and providing future perspectives in this field.


  • Open Access

    Signal-Based Methods in Dielectrophoresis for Cell Separation

    by Malihe Farasat, Ehsan Aalaei, Saeed Kheirati Ronizi, Atin Bakhshi, Shaghayegh Mirhosseini, Jun Zhang, Nam-Trung Nguyen, Navdi Kashaninejad

    Separation and detection of cells and particles in a suspension are essential for various applications, including biomedical investigations and clinical diagnostics. Microfluidics realizes the miniaturization of analytical devices by controlling the motion of a small volume of fluids in microchannels and microchambers. Accordingly, microfluidic devices have been widely used in particle/ cell manipulation processes. Different microfluidic methods for particle separation include dielectrophoretic, magnetic, optical, acoustic, hydrodynamic, and chemical techniques. Dielectrophoresis (DEP) is a method for manipulating polarizable particles’ trajectories in non-uniform electric fields using unique dielectric characteristics. It provides several advantages for dealing with neutral bioparticles owing to its sensitivity, selectivity, and noninvasive nature. This review provides a detailed study on the signal-based DEP methods that use the applied signal parameters, including frequency, amplitude, phase, and shape for cell/particle separation and manipulation. Rather than employing complex channels or time-consuming fabrication procedures, these methods realize sorting and detecting the cells/particles by modifying the signal parameters while using a simple device. In addition, these methods can significantly impact clinical diagnostics by making low-cost and rapid separation possible.


  • Thermal Performance Enhancement of Cylindrical Heat Sinks, Numerical Simulation, and Predictive Model

    by Sasan Kheirandish, Alireza Bordbar, Ehsan Aalaei, Reza Kamali

    The present numerical study uses finite-volume formulation to investigate the thermal performance of cylindrical heat sinks with different minichannel profiles and working fluids, including nanofluid and pure water. The numerical simulations are carried out in the laminar flow regime. The considered minichannel profiles include straight, converging-diverging, zigzag and wavy. Firstly, the straight design and the non-straight ones with equal amplitudes were compared based on their thermal performance, and it was observed that the wavy minichannel has an edge over the other profiles in the studied range of Reynolds numbers. Then, the wavy design was chosen and further investigated by changing the amplitude of the walls’ wave-form for the both working fluids. It was found that larger wave amplitudes raise the pressure drop and the heat transfer coefficient; however, the thermal performance parameter, which compares the relative importance of these two parameters, still follows an increasing trend. For the wavy minichannel heat sink, the thermal performance factor can increase up to 17% when the waviness is increased from 0.25 to 0.75 mm. Finally, after fitting the obtained numerical data, novel predictive correlations are derived based on different thermal and hydrodynamic parameters of the wavy heat sinks. This is achieved by optimization of independent variables using genetic algorithm.