Albert Wolthuis
Albert Wolthuis has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Kruit
Medical Laboratory, Nij Smellinghe Hospital, Drachten, the Netherlands
1 shared publication - Adrianus Sarinus Paulus van Trotsenburg
Amsterdam Gastroenterology Endocrinology and Metabolism Research Institute, Amsterdam, the Netherlands
1 shared publication - Anita Boelen
Endocrine Laboratory, Department of Laboratory Medicine, Amsterdam UMC, Location University of Amsterdam , 1105 AZ Amsterdam
1 shared publication - Annemieke C. Heijboer
Department of Laboratory Medicine, Endocrine Laboratory, Amsterdam UMC, University of Amsterdam , Amsterdam
1 shared publication - Ayse Y. Demir
Laboratory for Clinical Chemistry and Hematology , Meander Medical Centre , Amersfoort , The Netherlands
1 shared publication - Edwin Ten Boekel
Department of Clinical Chemistry, Hematology & Immunology, Northwest Clinics, Alkmaar, The Netherlands
1 shared publication
Latest Publications
- 1 November 2024
- Published by SAGE Publications in Thyroid®
- Vol. 34 (11) , 1346-1355
Age-Specific Reference Intervals for Thyroid-Stimulating Hormones and Free Thyroxine to Optimize Diagnosis of Thyroid Disease
Background: Thyroid-stimulating hormone (TSH) and subsequent free thyroxine (FT4) concentrations outside the reference interval (RI) are used to diagnose thyroid diseases. Most laboratories do not provide age-specific RIs for TSH and FT4 beyond childhood, although TSH concentrations vary with age. Therefore, we aimed to establish TSH and FT4 age-specific RIs throughout life and aimed to determine whether using these RIs would result in reclassification of thyroid disease diagnoses in adults. Methods: This multicenter retrospective cross-sectional study used big data to determine indirect RIs for TSH and FT4. These RIs were determined by TMC and refineR-analysis, respectively, using four different immunoassay platforms (Roche, Abbott, Siemens, and Beckman Coulter). Retrospective data (2008–2022) from 13 Dutch laboratories for general practitioners and local hospitals were used. RIs were evaluated per manufacturer. Age groups were established from 2 to 20 years by 2-year categories and decade categories between 20 and 100 years. Results: We included totally 7.6 million TSH and 2.2 million FT4 requests. TSH upper reference limits (URLs) and FT4 lower reference limits were higher in early childhood and decreased toward adulthood. In adulthood, TSH URLs increased from 60 years in men, and from 50 years in women, while FT4 URLs increased from 70 years onward. Using adult age-specific RIs resulted in a decrease in diagnoses of subclinical and overt hypothyroidism in women above 50 and men above 60 years in our Roche dataset. Conclusion: This study stressed the known importance of using age-specific RIs for TSH and FT4 in children. This study also showed the clinical relevance of using age-specific RIs for TSH in adulthood to reduce diagnoses of subclinical hypothyroidism in older persons. Therefore, implementation of adult TSH age-specific RIs should be strongly considered. Data are less uniform regarding FT4 age-specific RIs and more research should be performed before implementing these in clinical practice.
- 1 November 2024
- Published by SAGE Publications in Thyroid®
- Vol. 34 (11) , 1346-1355
Age-Specific Reference Intervals for Thyroid-Stimulating Hormones and Free Thyroxine to Optimize Diagnosis of Thyroid Disease
Background: Thyroid-stimulating hormone (TSH) and subsequent free thyroxine (FT4) concentrations outside the reference interval (RI) are used to diagnose thyroid diseases. Most laboratories do not provide age-specific RIs for TSH and FT4 beyond childhood, although TSH concentrations vary with age. Therefore, we aimed to establish TSH and FT4 age-specific RIs throughout life and aimed to determine whether using these RIs would result in reclassification of thyroid disease diagnoses in adults. Methods: This multicenter retrospective cross-sectional study used big data to determine indirect RIs for TSH and FT4. These RIs were determined by TMC and refineR-analysis, respectively, using four different immunoassay platforms (Roche, Abbott, Siemens, and Beckman Coulter). Retrospective data (2008–2022) from 13 Dutch laboratories for general practitioners and local hospitals were used. RIs were evaluated per manufacturer. Age groups were established from 2 to 20 years by 2-year categories and decade categories between 20 and 100 years. Results: We included totally 7.6 million TSH and 2.2 million FT4 requests. TSH upper reference limits (URLs) and FT4 lower reference limits were higher in early childhood and decreased toward adulthood. In adulthood, TSH URLs increased from 60 years in men, and from 50 years in women, while FT4 URLs increased from 70 years onward. Using adult age-specific RIs resulted in a decrease in diagnoses of subclinical and overt hypothyroidism in women above 50 and men above 60 years in our Roche dataset. Conclusion: This study stressed the known importance of using age-specific RIs for TSH and FT4 in children. This study also showed the clinical relevance of using age-specific RIs for TSH in adulthood to reduce diagnoses of subclinical hypothyroidism in older persons. Therefore, implementation of adult TSH age-specific RIs should be strongly considered. Data are less uniform regarding FT4 age-specific RIs and more research should be performed before implementing these in clinical practice.
- 11 May 2022
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 60 (7) , 1039-1045
Lack of analytical interference of dydrogesterone in progesterone immunoassays
Objectives Progesterone, a sex steroid, is measured in serum by immunoassay in a variety of clinical contexts. One potential limitation of steroid hormone immunoassays is interference caused by compounds with structural similarity to the target steroid of the assay. Dydrogesterone (DYD), an orally active stereoisomer of progesterone, is used for various indications in women’s health. Herein, we report a systematic in vitro investigation of potential interference of DYD and its active metabolite 20α-dihydrodydrogesterone (DHD) in seven widely used, commercially available progesterone assays. Methods Routine human plasma samples were anonymized and pooled to create three graded concentration levels of progesterone (P4 high, P4 medium, P4 low). Each pooled P4 plasma sample (6–7 mL) was spiked at high, medium, and “none” concentration with DYD/DHD and was divided into 0.5 mL aliquots. The blinded aliquots were analyzed by seven different laboratories with their routine progesterone assay (six different immunoassays and one liquid chromatography–tandem mass spectrometry assay, respectively) within the Dutch working group on endocrine laboratory diagnostics of the Dutch Foundation for Quality Assessments in Medical Laboratories. Results The sample recovery rate (P4 result obtained for sample spiked with DYD/DHD, divided by the result obtained for the corresponding sample with no DYD/DHD × 100) was within a ±10% window for the medium and high P4 concentrations, but more variable for the low P4 samples. The latter is, however, attributable to high inter- and intra-method variability at low P4 concentrations. Conclusions This study does not indicate any relevant interference of DYD/DHD within routinely used progesterone assays.
- 11 May 2022
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 60 (7) , 1039-1045
Lack of analytical interference of dydrogesterone in progesterone immunoassays
Objectives Progesterone, a sex steroid, is measured in serum by immunoassay in a variety of clinical contexts. One potential limitation of steroid hormone immunoassays is interference caused by compounds with structural similarity to the target steroid of the assay. Dydrogesterone (DYD), an orally active stereoisomer of progesterone, is used for various indications in women’s health. Herein, we report a systematic in vitro investigation of potential interference of DYD and its active metabolite 20α-dihydrodydrogesterone (DHD) in seven widely used, commercially available progesterone assays. Methods Routine human plasma samples were anonymized and pooled to create three graded concentration levels of progesterone (P4 high, P4 medium, P4 low). Each pooled P4 plasma sample (6–7 mL) was spiked at high, medium, and “none” concentration with DYD/DHD and was divided into 0.5 mL aliquots. The blinded aliquots were analyzed by seven different laboratories with their routine progesterone assay (six different immunoassays and one liquid chromatography–tandem mass spectrometry assay, respectively) within the Dutch working group on endocrine laboratory diagnostics of the Dutch Foundation for Quality Assessments in Medical Laboratories. Results The sample recovery rate (P4 result obtained for sample spiked with DYD/DHD, divided by the result obtained for the corresponding sample with no DYD/DHD × 100) was within a ±10% window for the medium and high P4 concentrations, but more variable for the low P4 samples. The latter is, however, attributable to high inter- and intra-method variability at low P4 concentrations. Conclusions This study does not indicate any relevant interference of DYD/DHD within routinely used progesterone assays.