Mohamed Elbayomi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohamed Elbayomi has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Michael Weyand
Department of Cardiac Surgery, Friedrich-Alexander-University
11 shared publicationsRene Tandler
Cardiac and Vascular Surgery, Klinikum Bayreuth, Medical Campus Oberfranken of Friedrich Alexander University
7 shared publicationsFrank Harig
Department of Cardiovascular Surgery, Friedrich-Alexander-University, Erlangen, Germany
6 shared publicationsChristian Heim
Department of Cardiac Surgery, Friedrich-Alexander-University, Erlangen, Germany
5 shared publicationsEhab Nooh
Department of Cardiovascular Surgery, Friedrich-Alexander-University, Erlangen, Germany
4 shared publicationsKatrin Steger
Department of Cardiac Surgery Friedrich‐Alexander‐University Erlangen‐Nuremberg Erlangen Germany
4 shared publications
Latest Publications
- Open Access
- 4 February 2025
- Published by Taylor & Francis in Annals of Medicine
- Vol. 57 (1) , 2460770
The mystery of methylene blue and its role in managing post-cardiac surgery vasoplegic shock
Vasoplegic syndrome is associated with high mortality. Methylene blue (MB) is a guanylate cyclase inhibitor that ameliorates this re-distributive type of shock. This study aims to investigate the outcome in patients who received MB early postoperatively. 2753 patients who underwent cardiac surgery utilizing cardiopulmonary bypass at our institution in a time interval of two years were identified. The incidence of vasoplegic syndrome was 7.2% (n = 200). Pharmacy records identified 84 patients (group 1, MB group) who received methylene blue and 116 patients (group 2, Control group) who didn't receive the drug. This single-center retrospective cohort study's primary outcome was in-hospital mortality. Secondary outcomes were postoperative hemodialysis, serum lactate levels at 24 h postoperatively, and intensive care unit stay length in days. MB patients have a shorter ICU stay as compared to the control group (9 ± 8 days vs. 16 ± 6.9; p-value <.001). In the control group, postoperative hemodialysis was higher (20% in the MB group and 40% in the control group; p-value <.05). At 24 h post-op, the methylene blue group had reduced serum lactate levels (1.8 ± 1.2 vs. 4 ± 1.8 in the control group; p-value <.001). The methylene blue group had a decreased 24-hour norepinephrine dose (1.5 ± 1.2 vs. 2.8 ± 2 in the control group; p-value <.05). In-hospital mortality was not significantly different between the two groups (38% in the MB group vs. 43% in the control group). Early postoperative administration of methylene blue in patients with vasoplegic syndrome shortens intensive care unit stay and contributes to less end-organ damage.
- 4 February 2025
- Published by Taylor & Francis in Annals of Medicine
- Vol. 57 (1) , 2460770
Open AccessThe mystery of methylene blue and its role in managing post-cardiac surgery vasoplegic shock
Vasoplegic syndrome is associated with high mortality. Methylene blue (MB) is a guanylate cyclase inhibitor that ameliorates this re-distributive type of shock. This study aims to investigate the outcome in patients who received MB early postoperatively. 2753 patients who underwent cardiac surgery utilizing cardiopulmonary bypass at our institution in a time interval of two years were identified. The incidence of vasoplegic syndrome was 7.2% (n = 200). Pharmacy records identified 84 patients (group 1, MB group) who received methylene blue and 116 patients (group 2, Control group) who didn't receive the drug. This single-center retrospective cohort study's primary outcome was in-hospital mortality. Secondary outcomes were postoperative hemodialysis, serum lactate levels at 24 h postoperatively, and intensive care unit stay length in days. MB patients have a shorter ICU stay as compared to the control group (9 ± 8 days vs. 16 ± 6.9; p-value <.001). In the control group, postoperative hemodialysis was higher (20% in the MB group and 40% in the control group; p-value <.05). At 24 h post-op, the methylene blue group had reduced serum lactate levels (1.8 ± 1.2 vs. 4 ± 1.8 in the control group; p-value <.001). The methylene blue group had a decreased 24-hour norepinephrine dose (1.5 ± 1.2 vs. 2.8 ± 2 in the control group; p-value <.05). In-hospital mortality was not significantly different between the two groups (38% in the MB group vs. 43% in the control group). Early postoperative administration of methylene blue in patients with vasoplegic syndrome shortens intensive care unit stay and contributes to less end-organ damage.
- Open Access
- 22 January 2024
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon Reports
- Vol. 13 (01) , e43-e47
A Firing Cannon: Bilateral Lower Limb Ischemia as a Manifestation of Cardiac Myxoma
Background Cardiac myxomas are the most common primary cardiac neoplasms. Case Description We present a case of a middle-aged lady with cardiac myxoma in her left atrium awaiting semi-elective surgery. During the preoperative period, the patient presented emergently with acute bilateral lower limb ischemia. This lady was fortunate to have these emboli fired towards a tissue with ischemia tolerance capacity. If these emboli had been directed toward the central nervous system, this patient would have experienced devastating complications and even death. Conclusion This presentation opens the debate on the timing of surgical intervention in myxoma patients.
- 22 January 2024
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon Reports
- Vol. 13 (01) , e43-e47
Open AccessA Firing Cannon: Bilateral Lower Limb Ischemia as a Manifestation of Cardiac Myxoma
Background Cardiac myxomas are the most common primary cardiac neoplasms. Case Description We present a case of a middle-aged lady with cardiac myxoma in her left atrium awaiting semi-elective surgery. During the preoperative period, the patient presented emergently with acute bilateral lower limb ischemia. This lady was fortunate to have these emboli fired towards a tissue with ischemia tolerance capacity. If these emboli had been directed toward the central nervous system, this patient would have experienced devastating complications and even death. Conclusion This presentation opens the debate on the timing of surgical intervention in myxoma patients.
- Open Access
- 11 November 2023
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 27 (2) , 162
Correction: Patient-tailored silicone plug for HeartMate 3™ left ventricular assist device explantation
- 11 November 2023
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 27 (2) , 162
Open AccessCorrection: Patient-tailored silicone plug for HeartMate 3™ left ventricular assist device explantation
- Open Access
- 18 May 2023
- Published by Wiley in Clinical Case Reports
- Vol. 11 (5)
Endovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis
Key Clinical Message: Complex presentations of MCS patients may necessitate a multidisciplinary approach involving HF cardiologists, CT surgeons, advanced cardiac imagers, and interventional cardiologists in order to define the optimal management strategy. Left ventricle assist devices (LVADs) provide life‐sustaining treatment for patients with terminal heart failure, but their intricacy allows for complications. One complication is LVAD outflow graft obstruction due to the graft's intraluminal thrombus or extraluminal compression. It may be treated endovascularly with stenting. We report an endovascular stenting of an outflow tract in HVAD™ (HeartWare Inc.) due to a pseudoaneurysm causing compression and kinking stenosis.
- 18 May 2023
- Published by Wiley in Clinical Case Reports
- Vol. 11 (5)
Open AccessEndovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis
Key Clinical Message: Complex presentations of MCS patients may necessitate a multidisciplinary approach involving HF cardiologists, CT surgeons, advanced cardiac imagers, and interventional cardiologists in order to define the optimal management strategy. Left ventricle assist devices (LVADs) provide life‐sustaining treatment for patients with terminal heart failure, but their intricacy allows for complications. One complication is LVAD outflow graft obstruction due to the graft's intraluminal thrombus or extraluminal compression. It may be treated endovascularly with stenting. We report an endovascular stenting of an outflow tract in HVAD™ (HeartWare Inc.) due to a pseudoaneurysm causing compression and kinking stenosis.
- Open Access
- 26 April 2023
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 27 (2) , 159-161
Patient-tailored silicone plug for HeartMate 3™ left ventricular assist device explantation
Patient-tailored silicone plug for HeartMate 3™ left ventricular assist device explantation in two successive males proceeded successfully. Given medical therapeutic advancements, FDA-approved plug systems designed by LVAD manufacturers themselves will be necessary for the near future to provide a safe and simple device explantation alternative that fulfills all regulatory standards.
- 26 April 2023
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 27 (2) , 159-161
Open AccessPatient-tailored silicone plug for HeartMate 3™ left ventricular assist device explantation
Patient-tailored silicone plug for HeartMate 3™ left ventricular assist device explantation in two successive males proceeded successfully. Given medical therapeutic advancements, FDA-approved plug systems designed by LVAD manufacturers themselves will be necessary for the near future to provide a safe and simple device explantation alternative that fulfills all regulatory standards.
- Open Access
- 6 April 2023
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 18 (1) , 1-6
The lost balloon at midnight: a case report reveals the inevitability of heart team existence
Dislodgement of a coronary stent-balloon catheter during percutaneous coronary intervention (PCI) is rare but is a life-threatening complication. A 57- year-old male presented with a non-ST elevation myocardial infarction (NSTEMI). Coronary angiography revealed total thrombotic occlusion of the Right coronary artery (RCA). Following the balloon dilatation of the RCA and while trying to retrieve the balloon catheter, the balloon was dislodged from the catheter shaft and entrapped in the coronary vessel. Under cardiopulmonary bypass, with antegrade cardioplegic arrest, the balloon was extracted through a coronary arteriotomy. Right coronary revascularization was done with reversed saphenous vein graft (SVG). Given the variety of equipment that can be retained in the coronary artery and the multitude of mechanisms by which it may be entrapped, there are no straightforward techniques applicable to all situations. Specific guidelines or recommendations on properly managing these potentially life-threatening complications do not exist. However, the most crucial issue in the management of these cases is the hemodynamic status of the patient as well as the coronary flow in the vessel with entrapped device or stent. In our case, the RCA was retrogradely perfused from the left coronary artery, which provided time to transfer the patient to cardiovascular surgical backup.
- 6 April 2023
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 18 (1) , 1-6
Open AccessThe lost balloon at midnight: a case report reveals the inevitability of heart team existence
Dislodgement of a coronary stent-balloon catheter during percutaneous coronary intervention (PCI) is rare but is a life-threatening complication. A 57- year-old male presented with a non-ST elevation myocardial infarction (NSTEMI). Coronary angiography revealed total thrombotic occlusion of the Right coronary artery (RCA). Following the balloon dilatation of the RCA and while trying to retrieve the balloon catheter, the balloon was dislodged from the catheter shaft and entrapped in the coronary vessel. Under cardiopulmonary bypass, with antegrade cardioplegic arrest, the balloon was extracted through a coronary arteriotomy. Right coronary revascularization was done with reversed saphenous vein graft (SVG). Given the variety of equipment that can be retained in the coronary artery and the multitude of mechanisms by which it may be entrapped, there are no straightforward techniques applicable to all situations. Specific guidelines or recommendations on properly managing these potentially life-threatening complications do not exist. However, the most crucial issue in the management of these cases is the hemodynamic status of the patient as well as the coronary flow in the vessel with entrapped device or stent. In our case, the RCA was retrogradely perfused from the left coronary artery, which provided time to transfer the patient to cardiovascular surgical backup.
- 2 March 2023
- Published by IMR Press in The Heart Surgery Forum
- Vol. 26 (2) , E164-E169
Single-Center Retrospective Analysis of Acute Type A Aortic Dissection Outcome and Reoperation Focusing on Extended Versus Limited Initial Repair
Background: The optimal management strategy for acute aortic type A dissection remains controversial. Whether a limited primary (index) repair would increase the need for late aortic reintervention is still an open debate. Methods: A total of 393 consecutive adult patients with acute type A aortic dissection who underwent cardiac surgery were analyzed. Our research hypothesis was whether limited aortic index repair (i.e., isolated aorta ascending replacement without an open distal anastomosis with and without a concomitant aortic valve replacement, including hemiarch replacement procedure) is associated with a higher incidence of late aortic reoperation compared with extended repair (i.e., any other surgical procedure that goes beyond that limited approach). Results: Type of the initial repair had no statically significant relationship with in-hospital mortality with a P-value of 0.12, however in multivariable analysis, cross-clamp time had a statistically significant relation with mortality (P = 0.4). From the patients who survived until discharge (N = 311), 40 patients needed a reoperation on the aorta; the mean interval until reoperation was 4.5 years. The relationship between the type of the initial repair and the need for reoperation didn’t reach a statically significant value (P = 0.9). In-hospitable mortality after the second operation was 10% (N = 4). Conclusion: We reached two conclusions. 1) An extended prophylactic repair in the initial operation of an acute type A aortic dissection might not lead to a lower incidence of reoperations on the aorta and could increase in-hospital mortality by increasing cross-clamp time, and 2) Reoperation on the aorta could be done safely with acceptable mortality outcomes.
- 2 March 2023
- Published by IMR Press in The Heart Surgery Forum
- Vol. 26 (2) , E164-E169
Single-Center Retrospective Analysis of Acute Type A Aortic Dissection Outcome and Reoperation Focusing on Extended Versus Limited Initial Repair
Background: The optimal management strategy for acute aortic type A dissection remains controversial. Whether a limited primary (index) repair would increase the need for late aortic reintervention is still an open debate. Methods: A total of 393 consecutive adult patients with acute type A aortic dissection who underwent cardiac surgery were analyzed. Our research hypothesis was whether limited aortic index repair (i.e., isolated aorta ascending replacement without an open distal anastomosis with and without a concomitant aortic valve replacement, including hemiarch replacement procedure) is associated with a higher incidence of late aortic reoperation compared with extended repair (i.e., any other surgical procedure that goes beyond that limited approach). Results: Type of the initial repair had no statically significant relationship with in-hospital mortality with a P-value of 0.12, however in multivariable analysis, cross-clamp time had a statistically significant relation with mortality (P = 0.4). From the patients who survived until discharge (N = 311), 40 patients needed a reoperation on the aorta; the mean interval until reoperation was 4.5 years. The relationship between the type of the initial repair and the need for reoperation didn’t reach a statically significant value (P = 0.9). In-hospitable mortality after the second operation was 10% (N = 4). Conclusion: We reached two conclusions. 1) An extended prophylactic repair in the initial operation of an acute type A aortic dissection might not lead to a lower incidence of reoperations on the aorta and could increase in-hospital mortality by increasing cross-clamp time, and 2) Reoperation on the aorta could be done safely with acceptable mortality outcomes.
- 2 March 2023
- Published by IMR Press in The Heart Surgery Forum
- Vol. 26 (2) , E170-E173
Better Late Than Never – A Case of a Congenital Left Partial Anomalous Pulmonary Venous Drainage Diagnosed and Treated in The Sixth Decade of Life
Partial anomalous pulmonary venous drainage (PAPVD) is a relatively uncommon cardiac anomaly. The diagnosis might be challenging as are the presenting symptoms. Its clinical course mimics more familiar diseases, e.g., pulmonary artery embolism. We present a case of PAPVD, which had been misdiagnosed for more than two decades. After establishing the correct diagnosis, the patient got his congenital anomaly surgically corrected and showed excellent cardiac recovery in the six months follow up.
- 2 March 2023
- Published by IMR Press in The Heart Surgery Forum
- Vol. 26 (2) , E170-E173
Better Late Than Never – A Case of a Congenital Left Partial Anomalous Pulmonary Venous Drainage Diagnosed and Treated in The Sixth Decade of Life
Partial anomalous pulmonary venous drainage (PAPVD) is a relatively uncommon cardiac anomaly. The diagnosis might be challenging as are the presenting symptoms. Its clinical course mimics more familiar diseases, e.g., pulmonary artery embolism. We present a case of PAPVD, which had been misdiagnosed for more than two decades. After establishing the correct diagnosis, the patient got his congenital anomaly surgically corrected and showed excellent cardiac recovery in the six months follow up.
- Open Access
- 1 February 2023
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 28 (2) , e13048
Wearable cardioverter defibrillator after cardiac surgery: Analysis of real‐life data from patients at transient risk of sudden cardiac death
Background: Especially in the first 3 months after cardiac surgery, patients are at transient risk of sudden cardiac death (SCD). To close the gap between hospital discharge and the final implantable cardioverter‐defibrillator (ICD) decision, guidelines recommend temporarily using a wearable cardioverter‐defibrillator (WCD) to protect these patients from SCD. We investigated real‐life data on the safety, effectiveness, and compliance of the WCD in this population.Methods: Data for analysis were collected via the Zoll Patient Management Network (ZPM) from patients who underwent cardiac surgery and who were discharged with a WCD between 2018 and 2021 at the Cardiac Surgery Center of the University of Erlangen in Germany.Results: The majority of the 55 patients were male (90.9%) and underwent a coronary artery bypass graft (80.0%). The number of patients with left ventricular ejection fraction (LVEF) >35% increased from 9.1% at the beginning of WCD use to 58.2% at the end of WCD use. Six ventricular tachycardia (VT) episodes occurred in four patients. The WCD appropriately defibrillated two patients with VT episodes. There were no inadequate shocks and no fatalities during the observation time. WCD wearing compliance was high, with a median wear time of 23.3 h/day.Conclusion: This retrospective analysis in a single cardiac surgery center confirms prior data on the safety and effectiveness of the WCD in patients in post‐surgery care in a real‐life setting. The WCD successfully protected patients from SCD during life‐threatening VT episodes. WCD wearing compliance was high.
- 1 February 2023
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 28 (2) , e13048
Open AccessWearable cardioverter defibrillator after cardiac surgery: Analysis of real‐life data from patients at transient risk of sudden cardiac death
Background: Especially in the first 3 months after cardiac surgery, patients are at transient risk of sudden cardiac death (SCD). To close the gap between hospital discharge and the final implantable cardioverter‐defibrillator (ICD) decision, guidelines recommend temporarily using a wearable cardioverter‐defibrillator (WCD) to protect these patients from SCD. We investigated real‐life data on the safety, effectiveness, and compliance of the WCD in this population.Methods: Data for analysis were collected via the Zoll Patient Management Network (ZPM) from patients who underwent cardiac surgery and who were discharged with a WCD between 2018 and 2021 at the Cardiac Surgery Center of the University of Erlangen in Germany.Results: The majority of the 55 patients were male (90.9%) and underwent a coronary artery bypass graft (80.0%). The number of patients with left ventricular ejection fraction (LVEF) >35% increased from 9.1% at the beginning of WCD use to 58.2% at the end of WCD use. Six ventricular tachycardia (VT) episodes occurred in four patients. The WCD appropriately defibrillated two patients with VT episodes. There were no inadequate shocks and no fatalities during the observation time. WCD wearing compliance was high, with a median wear time of 23.3 h/day.Conclusion: This retrospective analysis in a single cardiac surgery center confirms prior data on the safety and effectiveness of the WCD in patients in post‐surgery care in a real‐life setting. The WCD successfully protected patients from SCD during life‐threatening VT episodes. WCD wearing compliance was high.
- Open Access
- 20 November 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (12) , 5634-5638
Successive surgical repair of a progressive aortic dissection in a case of Loeys–Dietz Syndrome
IntroductionThe Frozen Elephant Trunk technique is a well-established treatment for aortic dissections (Stanford Type A) involving the aortic arch and descending aorta. The Thoraflex (TM) Hybrid prosthesis (Vascutek Ltd.), consisting of a proximal flexible conduit and a distal self-expanding covered stent, has consistently shown positive results in the treatment of this condition. Case DescriptionThe following is a description of such a staged reconstruction using the Thoraflex (TM) Hybrid Ante-Flo (TM) device, performed in a patient previously diagnosed with Loeys-Dietz Syndrome. After clamping the aorta proximally, an incision was taken at the distal end of the stent. Here, the distal end of the new prosthesis was inserted into the true lumen of the descending aorta and the stent was deployed. Following this, a bypass was established via the left atrium, and blood was returned to the lower body using the perfusion arm of the prosthesis with the proximal part of the descending aorta clamped. The collar of the prosthesis was sutured proximally to the aorta near the inlying previous stent. Air was removed via the perfusion arm of the prosthesis, which was then oversewn. DiscussionTo date, hybrid prostheses have only been used on the proximal aorta in patients with aortic aneurysms and aortic dissections (Stanford Type A). ConclusionUsing the described technique, it is possible to reconstruct the aortic anatomy using the available prostheses with accuracy and minimal complications.
- 20 November 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (12) , 5634-5638
Open AccessSuccessive surgical repair of a progressive aortic dissection in a case of Loeys–Dietz Syndrome
IntroductionThe Frozen Elephant Trunk technique is a well-established treatment for aortic dissections (Stanford Type A) involving the aortic arch and descending aorta. The Thoraflex (TM) Hybrid prosthesis (Vascutek Ltd.), consisting of a proximal flexible conduit and a distal self-expanding covered stent, has consistently shown positive results in the treatment of this condition. Case DescriptionThe following is a description of such a staged reconstruction using the Thoraflex (TM) Hybrid Ante-Flo (TM) device, performed in a patient previously diagnosed with Loeys-Dietz Syndrome. After clamping the aorta proximally, an incision was taken at the distal end of the stent. Here, the distal end of the new prosthesis was inserted into the true lumen of the descending aorta and the stent was deployed. Following this, a bypass was established via the left atrium, and blood was returned to the lower body using the perfusion arm of the prosthesis with the proximal part of the descending aorta clamped. The collar of the prosthesis was sutured proximally to the aorta near the inlying previous stent. Air was removed via the perfusion arm of the prosthesis, which was then oversewn. DiscussionTo date, hybrid prostheses have only been used on the proximal aorta in patients with aortic aneurysms and aortic dissections (Stanford Type A). ConclusionUsing the described technique, it is possible to reconstruct the aortic anatomy using the available prostheses with accuracy and minimal complications.