DBDavid Burke

David Burke

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David Burke has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Six-Month Pilot Testing of a Digital Health Tool to Support Effective Self-Care in People With Heart Failure: Mixed Methods Study

    by Alison Keogh, Carol Brennan, William Johnston, Jane Dickson, Stephen J Leslie, David Burke, Peter Megyesi, Brian Caulfield

    Background: Digital tools may support people to self-manage their heart failure (HF). Having previously outlined the human-centered design development of a digital tool to support self-care of HF, the next step was to pilot the tool over a period of time to establish people’s acceptance of it in practice. Objective: This study aims to conduct an observational pilot study to examine the usability, adherence, and feasibility of a digital health tool for HF within the Irish health care system. Methods: A total of 19 participants with HF were provided with a digital tool comprising a mobile app and the Fitbit Charge 4 and Aria Air smart scales for a period of 6 months. Changes to their self-care were assessed before and after the study with the 9-item European HF Self-care Behavior Scale (EHFScBS) and the Minnesota Living with HF Questionnaire (MLwHFQ) using a Wilcoxon signed rank test. After the study, 3 usability questionnaires were implemented and descriptively analyzed: the System Usability Scale (SUS), Wearable Technology Motivation Scale (WTMS), and Comfort Rating Scale (CRS). Participants also undertook a semistructured interview regarding their experiences with the digital tool. Interviews were analyzed deductively using the Theoretical Domains Framework. Results: Participants wore their devices for an average of 86.2% of the days in the 6-month testing period ranging from 40.6% to 98%. Although improvements in the EHFScBS and MLwHFQ were seen, these changes were not significant (P=.10 and P=.70, respectively, where P>.03, after a Bonferroni correction). SUS results suggest that the usability of this system was not acceptable with a median score of 58.8 (IQR 55.0-60.0; range 45.0-67.5). Participants demonstrated a strong motivation to use the system according to the WTMS (median 6.0, IQR 5.0-7.0; range 1.0-7.0), whereas the Fitbit was considered very comfortable as demonstrated by the low CRS results (median 0.0, IQR 0.0-0.0; range 0.0-2.0). According to participant interviews, the digital tool supported self-management through increased knowledge, improved awareness, decision-making, and confidence in their own data, and improving their social support through a feeling of comfort in being watched. Conclusions: The digital health tool demonstrated high levels of adherence and acceptance among participants. Although the SUS results suggest low usability, this may be explained by participants uncertainty that they were using it fully, rather than it being unusable, especially given the experiences documented in their interviews. The digital tool targeted key self-management behaviors and feelings of social support. However, a number of changes to the tool, and the health service, are required before it can be implemented at scale. A full-scale feasibility trial conducted at a wider level is required to fully determine its potential effectiveness and wider implementation needs.


  • Open Access

    Six-Month Pilot Testing of a Digital Health Tool to Support Effective Self-Care in People With Heart Failure: Mixed Methods Study (Preprint)

    by Alison Keogh, Carol Brennan, William Johnston, Jane Dickson, Stephen J Leslie, David Burke, Peter Megyesi, Brian Caulfield

    BACKGROUND Digital tools may support people to self-manage their heart failure (HF). Having previously outlined the human-centered design development of a digital tool to support self-care of HF, the next step was to pilot the tool over a period of time to establish people’s acceptance of it in practice. OBJECTIVE This study aims to conduct an observational pilot study to examine the usability, adherence, and feasibility of a digital health tool for HF within the Irish health care system. METHODS A total of 19 participants with HF were provided with a digital tool comprising a mobile app and the Fitbit Charge 4 and Aria Air smart scales for a period of 6 months. Changes to their self-care were assessed before and after the study with the 9-item European HF Self-care Behavior Scale (EHFScBS) and the Minnesota Living with HF Questionnaire (MLwHFQ) using a Wilcoxon signed rank test. After the study, 3 usability questionnaires were implemented and descriptively analyzed: the System Usability Scale (SUS), Wearable Technology Motivation Scale (WTMS), and Comfort Rating Scale (CRS). Participants also undertook a semistructured interview regarding their experiences with the digital tool. Interviews were analyzed deductively using the Theoretical Domains Framework. RESULTS Participants wore their devices for an average of 86.2% of the days in the 6-month testing period ranging from 40.6% to 98%. Although improvements in the EHFScBS and MLwHFQ were seen, these changes were not significant (P=.10 and P=.70, respectively, where P>.03, after a Bonferroni correction). SUS results suggest that the usability of this system was not acceptable with a median score of 58.8 (IQR 55.0-60.0; range 45.0-67.5). Participants demonstrated a strong motivation to use the system according to the WTMS (median 6.0, IQR 5.0-7.0; range 1.0-7.0), whereas the Fitbit was considered very comfortable as demonstrated by the low CRS results (median 0.0, IQR 0.0-0.0; range 0.0-2.0). According to participant interviews, the digital tool supported self-management through increased knowledge, improved awareness, decision-making, and confidence in their own data, and improving their social support through a feeling of comfort in being watched. CONCLUSIONS The digital health tool demonstrated high levels of adherence and acceptance among participants. Although the SUS results suggest low usability, this may be explained by participants uncertainty that they were using it fully, rather than it being unusable, especially given the experiences documented in their interviews. The digital tool targeted key self-management behaviors and feelings of social support. However, a number of changes to the tool, and the health service, are required before it can be implemented at scale. A full-scale feasibility trial conducted at a wider level is required to fully determine its potential effectiveness and wider implementation needs.

  • Open Access

    Human-Centered Design of a Digital Health Tool to Promote Effective Self-care in Patients With Heart Failure: Mixed Methods Study

    by William Johnston, Alison Keogh, Jane Dickson, Stephen J Leslie, Peter Megyesi, Rachelle Connolly, David Burke, Brian Caulfield

    Background: Effective self-care is an important factor in the successful management of patients with heart failure (HF). Despite the importance of self-care, most patients with HF are not adequately taught the wide range of skills required to become proficient in self-care. Digital health technology (DHT) may provide a novel solution to support patients at home in effective self-care, with the view to enhancing the quality of life and ultimately improving patient outcomes. However, many of the solutions developed to date have failed to consider users’ perspectives at the point of design, resulting in poor effectiveness. Leveraging a human-centered design (HCD) approach to the development of DHTs may lead to the successful promotion of self-care behaviors in patients with HF. Objective: This study aimed to outline the HCD, development, and evaluation process of a DHT designed to promote effective self-care in patients with HF. Methods: A design thinking approach within the HCD framework was undertaken, as described in the International Organization for Standardization 9241-210:2019 regulations, using a 5-step process: empathize, ideate, design, develop, and test. Patients with HF were involved throughout the design and evaluation of the system. The designed system was grounded in behavior change theory using the Theoretical Domains Framework and included behavior change techniques. Mixed methods were used to evaluate the DHT during the testing phase. Results: Steps 1 to 3 of the process resulted in a set of evidence- and user-informed design requirements that were carried forward into the iterative development of a version 1 system. A cross-platform (iOS and Android) mobile app integrated with Fitbit activity trackers and smart scales was developed. A 2-week user testing phase highlighted the ease of use of the system, with patients demonstrating excellent adherence. Qualitative analysis of semistructured interviews identified the early potential for the system to positively influence self-care. Specifically, users perceived that the system increased their confidence and motivation to engage in key self-care behaviors, provided them with skills and knowledge that made them more aware of the importance of self-care behaviors, and might facilitate timely help seeking. Conclusions: The use of an HCD methodology in this research has resulted in the development of a DHT that may engage patients with HF and potentially affect their self-care behaviors. This comprehensive work lays the groundwork for further development and evaluation of this solution before its implementation in health care systems. A detailed description of the HCD process used in this research will help guide the development and evaluation of future DHTs across a range of disease use cases.


  • Open Access

    Human-Centered Design of a Digital Health Tool to Promote Effective Self-care in Patients With Heart Failure: Mixed Methods Study (Preprint)

    by William Johnston, Alison Keogh, Jane Dickson, Stephen J Leslie, Peter Megyesi, Rachelle Connolly, David Burke, Brian Caulfield

    BACKGROUND Effective self-care is an important factor in the successful management of patients with heart failure (HF). Despite the importance of self-care, most patients with HF are not adequately taught the wide range of skills required to become proficient in self-care. Digital health technology (DHT) may provide a novel solution to support patients at home in effective self-care, with the view to enhancing the quality of life and ultimately improving patient outcomes. However, many of the solutions developed to date have failed to consider users’ perspectives at the point of design, resulting in poor effectiveness. Leveraging a human-centered design (HCD) approach to the development of DHTs may lead to the successful promotion of self-care behaviors in patients with HF. OBJECTIVE This study aimed to outline the HCD, development, and evaluation process of a DHT designed to promote effective self-care in patients with HF. METHODS A design thinking approach within the HCD framework was undertaken, as described in the International Organization for Standardization 9241-210:2019 regulations, using a 5-step process: empathize, ideate, design, develop, and test. Patients with HF were involved throughout the design and evaluation of the system. The designed system was grounded in behavior change theory using the Theoretical Domains Framework and included behavior change techniques. Mixed methods were used to evaluate the DHT during the testing phase. RESULTS Steps 1 to 3 of the process resulted in a set of evidence- and user-informed design requirements that were carried forward into the iterative development of a version 1 system. A cross-platform (iOS and Android) mobile app integrated with Fitbit activity trackers and smart scales was developed. A 2-week user testing phase highlighted the ease of use of the system, with patients demonstrating excellent adherence. Qualitative analysis of semistructured interviews identified the early potential for the system to positively influence self-care. Specifically, users perceived that the system increased their confidence and motivation to engage in key self-care behaviors, provided them with skills and knowledge that made them more aware of the importance of self-care behaviors, and might facilitate timely help seeking. CONCLUSIONS The use of an HCD methodology in this research has resulted in the development of a DHT that may engage patients with HF and potentially affect their self-care behaviors. This comprehensive work lays the groundwork for further development and evaluation of this solution before its implementation in health care systems. A detailed description of the HCD process used in this research will help guide the development and evaluation of future DHTs across a range of disease use cases.

  • Long‐term efficacy and safety of zotarolimus‐eluting stent in patients with diabetes mellitus: Pooled 5‐year results from the ENDEAVOR III and IV trials

    by Moshe Vardi, David A. Burke, Sripal Bangalore, Michael J. Pencina, Laura Mauri, David E. Kandzari, Martin B. Leon, Donald E. Cutlip

    Objective: To assess long‐term outcomes of Endeavor Zotarolimus‐eluting stent (E‐ZES) implantation in patients with diabetes mellitus (DM). Background: Patients with DM and coronary artery disease have lower restenosis with drug‐eluting stent (DES) compared with bare‐metal stents. Recent data suggest that the E‐ZES is inferior to other DES in this population.Methods: Patient‐level data for 601 patients with DM from the ENDEAVOR III and ENDEAVOR IV trials were pooled, of which 337 were treated with E‐ZES and 264 were treated with other DES. The primary outcome was target vessel failure (TVF) in the course of 5 years. Outcomes are reported as rates using Kaplan–Meier (KM) survival method and differences between E‐ZES and other stent types (sirolimus‐eluting stent or paclitaxel‐eluting stent) were compared using the log‐rank statistic. The independent effect of stent type on TVF was assessed using Cox proportional hazards regression.Results: Baseline characteristics were similar between the groups. Five‐year TVF KM rate estimate was numerically lower for E‐ZES, but the difference did not reach statistical significance (20.2 vs. 26.9%, P = 0.065). The 5‐year KM rate estimates of major adverse cardiac events (17.7 vs. 26.6%, P = 0.012), death (7.6 vs. 15.0%, P = 0.004), and myocardial infarction (1.3 vs. 5.1%, P = 0.011) were also lower for E‐ZES versus other DES. Conclusions: Patients with DM implanted with E‐ZES have favorable long‐term outcomes compared to first‐generation DES. Long‐term performance of DES should be assessed routinely and may differ from initial performance.