YKYeonggeun Kim

Yeonggeun Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yeonggeun Kim has a total of 41 co-authors. Here are the top co-authors by number of shared publications:

  • Hyung Ham Kim

    Department of Convergence IT Engineering, Pohang University of Science and Technology, Pohang, Republic of Korea

    5 shared publications
  • Chulhong Kim

    Pohang University of Science and Technology (POSTECH)

    4 shared publications
  • Hyojin Kim

    Departments of Electrical Engineering, Convergence IT Engineering, and Mechanical Engineering, School of Interdisciplinary Bioscience and Bioengineering, and Medical Device Innovation Center, Pohang University of Science and Technology, Pohang-si, Gyeongsangbuk-do 37673, Republic of Korea

    2 shared publications
  • Hyung Ham Kim

    Department of Electrical Engineering, Pohang University of Science and Technology, Pohang, Republic of Korea

    2 shared publications
  • Jeongwoo Park

    Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Republic of Korea

    2 shared publications
  • Jin Young Kim

    Department of Creative IT Engineering and Electrical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk-do 37673, Korea

    2 shared publications

Latest Publications

  • Real-Time Ultrasound Imaging System Utilizing Patch-Type Ultrasound Probe for Free-Flap Blood Perfusion Monitoring

    by Yeonggeun Kim, Jun Hyeok Kim, Yeon Hee Ryu, Honghyeon Ha, Su Jin Lee, Seung Cheol Lee, Chaieun Lim, Suk-Ho Moon, Hyung Ham Kim

    In the dynamic landscape of reconstructive surgery, the demand for real-time monitoring systems has become increasingly pronounced. In particular, free-flap procedures, where the vitality of the transferred flap depends on a stable blood supply, have witnessed an increase in the use of such systems. However, traditional monitoring techniques often cannot provide the level of precision and immediacy required to address perfusion issues promptly. Hence, this study developed a real-time ultrasound imaging system using a patch-type ultrasound probe for postoperative monitoring. A miniaturized, patch-type 9.7 MHz, 96-element linear array probe mounted in the housing with a flexible surface was proposed. Consequently, two-dimensional, color Doppler, and spectral Doppler modes were developed for continuous and real-time monitoring of blood flow in the flap. Preclinical evaluation with a mini-pig perforator flap model exhibited successful blood flow monitoring for 24 hours. The proposed continuous ultrasound blood flow monitoring is expected to be efficient, thereby enhancing precision, reducing complications, and improving patient outcomes in reconstructive surgery.


  • Top Cited Papers
    Open Access

    An ultrasensitive and broadband transparent ultrasound transducer for ultrasound and photoacoustic imaging in-vivo

    by Seonghee Cho, Minsu Kim, Joongho Ahn, Yeonggeun Kim, Junha Lim, Jeongwoo Park, Hyung Ham Kim, Won Jong Kim, Chulhong Kim

    Transparent ultrasound transducers (TUTs) can seamlessly integrate optical and ultrasound components, but acoustic impedance mismatch prohibits existing TUTs from being practical substitutes for conventional opaque ultrasound transducers. Here, we propose a transparent adhesive based on a silicon dioxide-epoxy composite to fabricate matching and backing layers with acoustic impedances of 7.5 and 4–6 MRayl, respectively. By employing these layers, we develop an ultrasensitive, broadband TUT with 63% bandwidth at a single resonance frequency and high optical transparency ( > 80%), comparable to conventional opaque ultrasound transducers. Our TUT maximises both acoustic power and transfer efficiency with maximal spectrum flatness while minimising ringdowns. This enables high contrast and high-definition dual-modal ultrasound and photoacoustic imaging in live animals and humans. Both modalities reach an imaging depth of > 15 mm, with depth-to-resolution ratios exceeding 500 and 370, respectively. This development sets a new standard for TUTs, advancing the possibilities of sensor fusion.


  • High-Frequency, Multiband Projector Using 1–3 Connectivity Lithium Niobate Composites With an Inversion Layer

    by Yeonggeun Kim, Jinhee Yoo, Youngsub Lim, Seungki Min, Seungjin Lee, Hyung Ham Kim

    In this study, we demonstrate a sound navigation and ranging (Sonar) projector with a higher and wider frequency range using an inversion layer. Because the working frequency range of the acoustic transducers is limited, several types of the transducers are required to operate at different frequencies for underwater acoustic systems. Multi-band acoustic transducers have been developed to solve this problem; however, the operating frequency range is only 100–200 kHz. To overcome this, we used lithium niobate (LN) to maximize the advantage of using an inversion layer. The characteristics of LN according to the angle of the cutting direction and the characteristics of 1–3 composites were calculated, and finite element method (FEM) simulations were performed using these calculated values. The simulated and measured results of the inversion layer composite and fabricated projectors showed similar electrical impedance responses and transmitting voltage response (TVR). Resonance of the inversion layer composite occurred at 330, 680, and 1100 kHz. The fabricated projector had resonance frequencies of 390 and 790 kHz, and the working frequency range of the fabricated projector was 270–900 kHz. We expect that the developed projector will exhibit excellent performance in underwater navigation applications, such as small-scale object detection and terrain mapping.


  • Open Access

    Fully integrated photoacoustic microscopy and photoplethysmography of human in vivo

    by Joongho Ahn, Jin Woo Baik, Yeonggeon Kim, Karam Choi, Jeongwoo Park, Hyojin Kim, Jin Young Kim, Hyung Ham Kim, Sung Hyun Nam, Chulhong Kim


  • Top Cited Papers
    Open Access

    Deep learning acceleration of multiscale superresolution localization photoacoustic imaging

    by Jongbeom Kim, Gyuwon Kim, Lei Li, Pengfei Zhang, Jin Young Kim, Yeonggeun Kim, Hyung Ham Kim, Lihong V. Wang, Seungchul Lee, Chulhong Kim

    A superresolution imaging approach that localizes very small targets, such as red blood cells or droplets of injected photoacoustic dye, has significantly improved spatial resolution in various biological and medical imaging modalities. However, this superior spatial resolution is achieved by sacrificing temporal resolution because many raw image frames, each containing the localization target, must be superimposed to form a sufficiently sampled high-density superresolution image. Here, we demonstrate a computational strategy based on deep neural networks (DNNs) to reconstruct high-density superresolution images from far fewer raw image frames. The localization strategy can be applied for both 3D label-free localization optical-resolution photoacoustic microscopy (OR-PAM) and 2D labeled localization photoacoustic computed tomography (PACT). For the former, the required number of raw volumetric frames is reduced from tens to fewer than ten. For the latter, the required number of raw 2D frames is reduced by 12 fold. Therefore, our proposed method has simultaneously improved temporal (via the DNN) and spatial (via the localization method) resolutions in both label-free microscopy and labeled tomography. Deep-learning powered localization PA imaging can potentially provide a practical tool in preclinical and clinical studies requiring fast temporal and fine spatial resolutions.


  • Performance comparison of high-speed photoacoustic microscopy: opto-ultrasound combiner versus ring-shaped ultrasound transducer

    by Hyojin Kim, Jin Young Kim, Seonghee Cho, Joongho Ahn, Yeonggeun Kim, Hyungham Kim, Chulhong Kim

    Photoacoustic microscopy (PAM) embedded with a 532 nm pulse laser is widely used to visualize the microvascular structures in both small animals and humans in vivo. An opto-ultrasound combiner (OUC) is often utilized in high-speed PAM to confocally align the optical and acoustic beams to improve the system's sensitivity. However, acoustic impedance mismatch in the OUC results in little improvement in the sensitivity. Alternatively, a ring-shaped ultrasound transducer (RUT) can also accomplish the confocal configuration. Here, we compare the performance of OUC and RUT modules through ultrasound pulse-echo tests and PA imaging experiments. The signal-to-noise ratios (SNRs) of the RUT-based system were 15 dB, 12 dB, and 7 dB higher when compared to the OUC-based system for ultrasound pulse-echo test, PA phantom imaging test, and PA in-vivo imaging test, respectively. In addition, the RUT-based system could image the microvascular structures of small parts of a mouse body in a few seconds with minimal loss in SNR. Thus, with increased sensitivity, improved image details, and fast image acquisition, we believe the RUT-based systems could play a significant role in the design of future fast-PAM systems.


  • Open Access

    Thermal Ablation and High-Resolution Imaging Using a Back-to-Back (BTB) Dual-Mode Ultrasonic Transducer: In Vivo Results

    by Hae Gyun Lim, Hyunhee Kim, Kyungmin Kim, Jeongwoo Park, Yeonggeun Kim, Jinhee Yoo, Dasom Heo, Jinhwan Baik, Sung-Min Park, Hyung Ham Kim

    We present a back-to-back (BTB) structured, dual-mode ultrasonic device that incorporates a single-element 5.3 MHz transducer for high-intensity focused ultrasound (HIFU) treatment and a single-element 20.0 MHz transducer for high-resolution ultrasound imaging. Ultrasound image-guided surgical systems have been developed for lesion monitoring to ensure that ultrasonic treatment is correctly administered at the right locations. In this study, we developed a dual-element transducer composed of two elements that share the same housing but work independently with a BTB structure, enabling a mode change between therapy and imaging via 180-degree mechanical rotation. The optic fibers were embedded in the HIFU focal region of ex vivo chicken breasts and the temperature change was measured. Images were obtained in vivo mice before and after treatment and compared to identify the treated region. We successfully acquired B-mode and C-scan images that display the hyperechoic region indicating coagulation necrosis in the HIFU-treated volume up to a depth of 10 mm. The compact BTB dual-mode ultrasonic transducer may be used for subcutaneous thermal ablation and monitoring, minimally invasive surgery, and other clinical applications, all with ultrasound only.