NSNatalia M. Santos

Natalia M. Santos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Natalia M. Santos has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Microwave Sensor Based on Concentric Split-Ring Resonators for Blood Urea Detection: A Novel Tool for Chronic Kidney Disease Diagnosis

    by Mateus I. O. Souza, Natália M. Santos, Laudemir C. Varanda, Vinicius M. Pepino, Ben-Hur V. Borges

    Chronic kidney disease (CKD) affects millions of people worldwide, making early diagnosis critical for effective management and healthcare cost reduction. Monitoring blood urea levels is essential for this purpose. In this paper, we present a microwave sensor capable of detecting urea concentrations within the clinical range required for CKD diagnosis, a sensitivity not achieved by previous microwave (MW) based approaches. The proposed device operates without reagents or enzymes, requires no specialized personnel and offers an extended lifespan, ease of use, and sensitivity comparable to conventional optical sensors. Our work consists of two main steps. First, we conducted a dielectric characterization of artificial blood plasma (ABPS) and urea-enriched ABPS (ABPSU, 320 mg/dL) over a frequency range of 500 MHz to 10 GHz. The results revealed that the most significant differentiation between samples occurs at low frequencies, particularly in the loss tangent rather than in the real part of the dielectric constant, thereby identifying the optimal frequency range for sensor design. In the second step, we designed a double concentric circular split-ring resonator (DCCSRR) on a 49 mm × 45 mm Rogers 5880™ substrate. A dedicated optimization protocol enhanced both the resonance peak amplitude and the quality factor of the sensor’s fundamental mode. After fabrication, the DCCSRR was tested for urea concentrations ranging from 10 to 320 mg/dL, exhibiting measurable variations in S21 (dB) and frequency shifts around 575 MHz. This study establishes the first microwave sensor operating within the urea concentration range necessary for CKD diagnosis, paving the way for practical microwave-based urea monitoring.


  • Open Access

    Microwave Glucose Sensing Using Double Circular Split Ring Resonators for Improved Sensitivity: The Role of Artificial Blood Plasma and Deionized Water

    by Mateus I. O. Souza, Natália M. Santos, Júlio C. P. Alarcon, Laudemir C. Varanda, Vinicius M. Pepino, Ben-Hur V. Borges

    In 2021, approximately 537 million people were diagnosed with diabetes mellitus. With rates expected to rise, health expenditures are projected to reach one trillion USD by 2030. Thus, measuring glucose levels is essential for rationalizing the costs of public health systems. In this context, this paper presents two major contributions. First, it demonstrates that using deionized water (DI-water) as a reference for glucose sensing is not a reliable approach for representing human blood plasma (BP), as it lacks ions and suppresses essential effects such as losses. As an alternative, we investigate the use of an artificial blood plasma solution (ABPS) that closely resembles real human BP. Characterized over a range from 500 MHz to 10 GHz, ABPS shows marginal differences in real permittivity but significant differences in imaginary permittivity compared to DI-water. The second contribution is the design of a highly sensitive microwave sensor based on double concentric circular split ring resonator (DCCSRR) on a 49 mm × 45 mm ROGERS 5880 TM substrate. This sensor can differentiate glucose concentrations from 0 to 400 mg/dL, exceeding the relevant range for diabetic individuals (50-300 mg/dL). The DCCSRR operates at 2.48 GHz and can detect minimal concentration variations of 25 mg/dL in low concentrations, representing a significant advancement in the field. Differently from most sensitive approaches available to date, this structure operates in a non-licensed band and in a fully passive form, offering flexibility for implementation and low cost. These characteristics position it as a state-of-the-art solution in microwave glucose sensors.


  • Open Access

    Microwave Glucose Sensing Using Double Circular Split Ring Resonators for Improved Sensitivity: The Role of Artificial Blood Plasma and Deionized Water

    by Mateus Isaac de Oliveira Souza, Natália M. Santos, Julio Alarcon, Laudemir C. Varanda, Vinicius Marrara Pepino, Ben-Hur Viana Borges

    In 2021, approximately 537 million people were diagnosed with diabetes mellitus. With rates expected to rise, health expenditures are projected to reach one trillion USD by 2030. Thus, measuring glucose levels is essential for rationalizing the costs of public health systems. In this context, this paper presents two major contributions. First, it demonstrates that using deionized water (DI-water) as a reference for glucose sensing is not a reliable approach for representing human blood plasma (BP), as it lacks ions and suppresses essential effects such as losses. As an alternative, we investigate the use of an artificial blood plasma solution (ABPS) that closely resembles real human BP. Characterized over a range from 500 MHz to 10 GHz, ABPS shows marginal differences in real permittivity but significant differences in imaginary permittivity compared to DIwater. The second contribution is the design of a highly sensitive microwave resonator sensor based on concentric double circular split ring resonator (DCCSRR) on a ROGERS 5880 TM substrate. This sensor can differentiate glucose concentrations from 0 to 400 mg/dL, exceeding the relevant range for diabetic individuals (50-300 mg/dL). The DCCSRR operates at 2.48 GHz and can detect minimal concentration variations of 25 mg/dL in low concentrations, representing a significant advancement in the field. Differently from most sensitive approaches available to date, this structure operates in a non-licensed band and in a fully passive form, offering flexibility for implementation and low cost. These characteristics position it as a state-of-the-art solution in microwave glucose sensors. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.

  • Open Access

    Ultrasmall Superparamagnetic Iron Oxide Nanoparticles Synthesized by Micellar Approach as a Potential Dual-Mode T1-T2 Contrast Agent

    by Laudemir Carlos Varanda, Watson Beck, Simone J. S. Lopes, Daniel A. Moraes, Natalia M. Santos, Maria Eduarda S. D. Lino

    Purpose: A micellar approach is used to synthesize Ultrasmall Superparamagnetic Iron Oxide Nanoparticles (USPIONs) with an average diameter of 3.4±0.5 nm, suitable for dual-mode T1-T2 contrast agents. Methods: Micelles with 3.8 nm, measured by dynamic light scattering, were obtained by self-organizing the surfactant iron(III) dodecyl sulfate (IDS) in 1-octanol. IDS was prepared by replac-ing Na+ cation in sodium dodecyl sulfate molecule, and its critical micelle concentration (CMC) was measured by electrical conductivity. The USPIONs were synthesized in a biphasic system: IDS in octanol (55% above the CMC) and water containing NaBH4. Results: A yellow precipitate is immediately formed at the water/alcohol interface, rapidly changes to a black one, and transfers to the aqueous phase. The magnetite phase was confirmed by X-ray diffraction and Mössbauer spectroscopy. The magnetic behavior shows a major paramagnetic char-acter with a weak ferromagnetic component at 5 K, the latter attributed to the interparticle couplings below its blocking temperature (TB = 35 K). The particles were coated with carboxymethyl dextran, showing an isoelectric point of 2.7 with electrokinetic potential around -30 mV in the physiological pH range. Magnetic relaxation measurements showed relaxivity values r1 = 0.17 mM-1 s-1 and r2 = 1.73 mM-1 s-1 (r2/r1 = 10) in a 3T field. These values infer that the ultrasmall size affects the interac-tions with the protons of the nearby water molecules. The r2 value decreases because the core mag-netization decreases with size; r1 intensifies due to the high surface. Conclusion: The results show a system with high colloidal stability, non-cytotoxic, and potential application as T1-T2 dual-mode contrast agents.


  • Open Access

    Green synthesis of colloidal gold nanoparticles using latex from Hevea brasiliensis and evaluation of their in vitro cytotoxicity and genotoxicity

    by Natália M. Santos, Andressa S. Gomes, Dalita G.S.M. Cavalcante, Luis F. Santos, Silvio R. Teixeira, Flávio C. Cabrera, Aldo Eloizo Job

    Latex extracted from Hevea brasiliensis tree has been used as a green alternative for preparing gold nanoparticles (Au NPs); however, no study evaluating the cytotoxic and genotoxic potential of Au NPs synthesised using H. brasiliensis has been published. The present study aimed to synthesise and characterise colloidal Au NPs using latex from H. brasiliensis and to evaluate their in vitro cytotoxicity and genotoxicity. Ideal conditions for the green synthesis of Au NPs were studied. In vitro cytotoxicity and genotoxicity of Au NPs in CHO‐K1 cells was also evaluated. Our findings indicated that the ideal synthesis conditions of pH, temperature, reduction time, and concentrations of latex and HAuCl 4 were 7.0, 85°C, 120 min, 3.3 mg/mL, and 5.0 mmol/L, respectively. LC50 24 h of Au NPs was 119.164 ± 5.31 μg/mL. Lowest concentration of Au NPs tested presented minimal cytotoxicity and genotoxicity. However, high concentrations of Au NPs promoted DNA damage and cell death via apoptosis. On the basis of these findings, the authors optimised the use of an aqueous solution of H. brasiliensis latex as a reducing/stabilising agent for the green synthesis of Au NPs. Low concentrations of these NPs are biocompatible in normal cell types, suggesting that these NPs may be used in biological applications.