CZCiro Zinno

Ciro Zinno

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ciro Zinno has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reconnecting the vagus nerve to the heart through nerve conduit preserves cardiac function in a minipig model of right cardiac vagotomy

    by Anar Dushpanova, Eugenio Redolfi-Riva, Valentina Casieri, Letizia Brogi, Chrysanthos Grigoratos, Fabio Bernini, Domiziana Terlizzi, Khatia Gabisonia, Ciro Zinno, Filippo Agnesi, et al.

    The right vagus nerve is essential for cardiac homeostasis, and its intrathoracic resection can lead to postoperative cardiac complications. Strategies to restore vagal innervation after transection at the cardiac level remain lacking. Here, we show that early reconnection of the right vagus nerve using an implantable chitosan/poly-ε-caprolactone cuff-like nerve guidance conduit preserved cardiac mechanical function in adult male minipigs subjected to right cardiac vagotomy. Treated animals displayed improved global circumferential, longitudinal, and radial strains and reduced diastolic dyssynchrony. Histological analysis revealed partial repair with about 20% viable vagal fascicles, restoration of myocardial parasympathetic fibers, normalization of oxidative stress and aging markers, and prevention of interstitial fibrosis. These findings suggest that maintaining even limited vagal input prevents early cardiac remodeling by mitigating oxidative stress–induced premature senescence of cardiac cells. Reconnection of the right vagus nerve with chitosan/poly-ε-caprolactone cuff-like nerve guidance conduit may represent a therapeutic approach to preventing right vagotomy–induced heart failure after thoracic surgery or cardiothoracic transplantation.


  • Open Access

    Development of Poly(3,4-ethylenedioxythiophene) Polystyrene Sulfonate/Triton X-100-Conductive Hydrogels for Bioelectronic Applications

    by Mario Milazzo, Francesco Palazzo, Ciro Zinno, Marta Bianchini, Silvestro Micera, Eugenio Redolfi Riva

    Conductive hydrogels based on poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) are widely used in bioelectronics because they combine printability with good electrical conductivity

  • Open Access

    Implementation of an epicardial implantable MEMS sensor for continuous and real-time postoperative assessment of left ventricular activity in adult minipigs over a short- and long-term period

    by C. Zinno, F. Agnesi, G. D'ALesio, A. Dushpanova, L. Brogi, D. Camboni, F. Bernini, D. Terlizzi, V. Casieri, K. Gabisonia, et al.

    The sensing of left ventricular (LV) activity is fundamental in the diagnosis and monitoring of cardiovascular health in high-risk patients after cardiac surgery to achieve better short- and long-term outcome. Conventional approaches rely on noninvasive measurements even if, in the latest years, invasive microelectromechanical systems (MEMS) sensors have emerged as a valuable approach for precise and continuous monitoring of cardiac activity. The main challenges in designing cardiac MEMS sensors are represented by miniaturization, biocompatibility, and long-term stability. Here, we present a MEMS piezoresistive cardiac sensor capable of continuous monitoring of LV activity over time following epicardial implantation with a pericardial patch graft in adult minipigs. In acute and chronic scenarios, the sensor was able to compute heart rate with a root mean square error lower than 2 BPM. Early after up to 1 month of implantation, the device was able to record the heart activity during the most important phases of the cardiac cycle (systole and diastole peaks). The sensor signal waveform, in addition, closely reflected the typical waveforms of pressure signal obtained via intraventricular catheters, offering a safer alternative to heart catheterization. Furthermore, histological analysis of the LV implantation site following sensor retrieval revealed no evidence of myocardial fibrosis. Our results suggest that the epicardial LV implantation of an MEMS sensor is a suitable and reliable approach for direct continuous monitoring of cardiac activity. This work envisions the use of this sensor as a cardiac sensing device in closed-loop applications for patients undergoing heart surgery.


  • Open Access

    Improved Physiochemical Properties of Chitosan@PCL Nerve Conduits by Natural Molecule Crosslinking

    by Marta Bianchini, Ciro Zinno, Silvestro Micera, Eugenio Redolfi Riva

    Nerve conduits may represent a valuable alternative to autograft for the regeneration of long-gap damages. However, no NCs have currently reached market approval for the regeneration of limiting gap lesions, which still represents the very bottleneck of this technology. In recent years, a strong effort has been made to envision an engineered graft to tackle this issue. In our recent work, we presented a novel design of porous/3D-printed chitosan/poly-ε-caprolactone conduits, coupling freeze drying and additive manufacturing technologies to yield conduits with good structural properties. In this work, we studied genipin crosslinking as strategy to improve the physiochemical properties of our conduit. Genipin is a natural molecule with very low toxicity that has been used to crosslink chitosan porous matrix by binding the primary amino group of chitosan chains. Our characterization evidenced a stabilizing effect of genipin crosslinking towards the chitosan matrix, with reported modified porosity and ameliorated mechanical properties. Given the reported results, this method has the potential to improve the performance of our conduits for the regeneration of long-gap nerve injuries.


  • Open Access

    Neural Stimulation Hardware for the Selective Intrafascicular Modulation of the Vagus Nerve

    by I. Strauss, F. Agnesi, C. Zinno, A. Giannotti, A. Dushpanova, V. Casieri, D. Terlizzi, F. Bernini, K. Gabisonia, Y. Wu, et al.

    The neural stimulation of the vagus nerve is able to modulate various functions of the parasympathetic response in different organs. The stimulation of the vagus nerve is a promising approach to treating inflammatory diseases, obesity, diabetes, heart failure, and hypertension. The complexity of the vagus nerve requires highly selective stimulation, allowing the modulation of target-specific organs without side effects. Here, we address this issue by adapting a neural stimulator and developing an intraneural electrode for the particular modulation of the vagus nerve. The neurostimulator parameters such as amplitude, pulse width, and pulse shape were modulated. Single-, and multi-channel stimulation was performed at different amplitudes. For the first time, a polyimide thin-film neural electrode was designed for the specific stimulation of the vagus nerve. In vivo experiments were performed in the adult minipig to validate to elicit electrically evoked action potentials and to modulate physiological functions, validating the spatial selectivity of intraneural stimulation. Electrochemical tests of the electrode and the neurostimulator showed that the stimulation hardware was working correctly. Stimulating the porcine vagus nerve resulted in spatially selective modulation of the vagus nerve. ECAP belonging to alpha and beta fibers could be distinguished during single- and multi-channel stimulation. We have shown that the here presented system is able to activate the vagus nerve and can therefore modulate the heart rate, diastolic pressure, and systolic pressure. The here presented system may be used to restore the cardiac loop after denervation by implementing biomimetic stimulation patterns. Presented methods may be used to develop intraneural electrodes adapted for various applications.


  • Open Access

    Neural stimulation hardware for the selective intrafascicular modulation of the vagus nerve

    by I. Strauss, F. Agnesi, C. Zinno, A. Giannotti, A. Dushpanova, V. Casieri, D. Terlizzi, F. Bernini, K. Gabisonia, Y. Wu, et al.

    The neural stimulation of the vagus nerve is able to modulate various functions of the parasympathetic response in different organs. The stimulation of the vagus nerve is a promising approach to treating inflammatory diseases, obesity, diabetes, heart failure, and hypertension. The complexity of the vagus nerve requires highly selective stimulation, allowing the modulation of target-specific organs without side effects. Here, we address this issue by adapting a neural stimulator and developing an intraneural electrode for the particular modulation of the vagus nerve. The neurostimulator parameters such as amplitude, pulse width, and pulse shape were modulated. Single-, and multi-channel stimulation was performed at different amplitudes. For the first time, I polyimide thin-film neural electrode was designed for the specific stimulation of the vagus nerve. In vivo experiments were performed in the adult minipig to validate to elicit electrically evoked action potentials and to modulate physiological functions selectively, validating the selectivity of intraneural stimulation. Electrochemical tests of the electrode and the neurostimulator showed that the stimulation hardware was working correctly. Stimulating the porcine vagus nerve resulted in selective modulation of the vagus nerve. Alpha, beta, and theta waves could be distinguished during single- and multi-channel stimulation. We have shown that the here presented system is able to activate the vagus nerve selectively and can therefore modulate the heart rate, diastolic pressure, and systolic pressure. The here presented system may be used to restore the cardiac loop after denervation by implementing biomimetic stimulation patterns. Presented methods may be used to develop intraneural electrodes adapted for various applications.

  • Open Access

    Cardiovascular Response to Intraneural Right Vagus Nerve Stimulation in Adult Minipig

    by Filippo Agnesi, Ciro Zinno, Ivo Strauss, Anar Dushpanova, Valentina Casieri, Fabio Bernini, Domiziana Terlizzi, Khatia Gabisonia, Valentina Paggi, Stéphanie P. Lacour, et al.


  • Implantable Fiber Bragg Grating Sensor for Continuous Heart Activity Monitoring: Ex-Vivo and In-Vivo Validation

    by Davide Ferraro, Giacomo D'ALesio, Domenico Camboni, Ciro Zinno, Leone Costi, Max Haberbusch, Philipp Aigner, Martin Maw, Thomas Schloglhofer, Ewald Unger, et al.

    Continuous and reliable cardiac function monitoring could improve medication adherence in patients at risk of heart failure. This work presents an innovative implantable Fiber Bragg Grating-based soft sensor designed to sense mechanical cardiac activity. The sensor was tested in an isolated beating ovine heart platform, with 3 different hearts operated in wide-ranging conditions. In order to investigate the sensor capability to track the ventricular beats in real-time, two causal algorithms were proposed for detecting the beats from sensor data and to discriminate artifacts. The first based on dynamic thresholds while the second is a hybrid convolutional and recurrent Neural Network. An error of 2.7 ± 0.7 beats per minute was achieved in tracking the heart rate. Finally, we have confirmed the sensor reliability in monitoring the heart activity of healthy adult minipig with an error systematically lower than 1 Bpm.