Zixuan Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zixuan Lu has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Roisin Meabh Owens
University of Cambridge
13 shared publications - Konstantinos Kallitsis
Department of Chemical Engineering and Biotechnology, University of Cambridge
6 shared publications - Achilleas Savva
Department of Microelectronics Faculty of Electrical Engineering, Mathematics and Computer Science Delft University of Technology Delft Netherlands
5 shared publications Alberto Salleo
Department of Materials Science and Engineering Stanford University Stanford CA 94305 USA
4 shared publicationsAimee Withers
Department of Chemical Engineering and Biotechnology University of Cambridge Philippa Fawcett Drive Cambridge CB3 0AS UK
3 shared publications- Ekaterina Selivanovitch
R.F. School of Chemical and Biomolecular Engineering, Cornell University, Ithaca, New York 14853, United States
3 shared publications
Latest Publications
- Open Access
- 2 July 2026
- Published by Springer Nature in Communications Materials
- Vol. 7 (1)
Reducing foreign body reaction via neural interfaces coated with iPSC-derived neuronal membranes
Advancements in neural interfaces have been hindered by the foreign body reaction (FBR), which drives inflammation and fibrotic encapsulation of implanted probes, limiting long-term performance. Biomimetic strategies that better match biological form and mechanics have recently emerged to address this challenge. Here, we mitigate FBR by incorporating human iPSC-derived neuronal membranes as biological mediators between device and host tissue, reducing inflammation and fibrosis while improving long-term stability and signal quality. We integrate flexible electronics with bioengineering to extract and assemble human iPSC-derived neuronal membranes, first characterizing their structural integrity and electrical sealing properties in vitro. In vivo experiments in rats show that subdurally implanted membrane-based biohybrid neural interfaces significantly reduce FBR at day 28 compared to controls, while preserving high signal-to-noise ratios. Moreover, chronic recordings in freely moving, awake animals demonstrate stable single-neuron activity for up to two months. The neuronal lipid layer provides a controlled increase in impedance while enabling reliable long-term recording stability. These results highlight the promise of cell-derived, cell-free biohybrid neural interfaces to enhance implant integration and function. Modulating membrane lipid and protein composition may further enable tailoring to specific anatomical and pathological contexts.
- 2 July 2026
- Published by Springer Nature in Communications Materials
- Vol. 7 (1)
Open AccessReducing foreign body reaction via neural interfaces coated with iPSC-derived neuronal membranes
Advancements in neural interfaces have been hindered by the foreign body reaction (FBR), which drives inflammation and fibrotic encapsulation of implanted probes, limiting long-term performance. Biomimetic strategies that better match biological form and mechanics have recently emerged to address this challenge. Here, we mitigate FBR by incorporating human iPSC-derived neuronal membranes as biological mediators between device and host tissue, reducing inflammation and fibrosis while improving long-term stability and signal quality. We integrate flexible electronics with bioengineering to extract and assemble human iPSC-derived neuronal membranes, first characterizing their structural integrity and electrical sealing properties in vitro. In vivo experiments in rats show that subdurally implanted membrane-based biohybrid neural interfaces significantly reduce FBR at day 28 compared to controls, while preserving high signal-to-noise ratios. Moreover, chronic recordings in freely moving, awake animals demonstrate stable single-neuron activity for up to two months. The neuronal lipid layer provides a controlled increase in impedance while enabling reliable long-term recording stability. These results highlight the promise of cell-derived, cell-free biohybrid neural interfaces to enhance implant integration and function. Modulating membrane lipid and protein composition may further enable tailoring to specific anatomical and pathological contexts.
- Open Access
- 20 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 10240
Implantable bioelectronics for gut electrophysiology
A major regulator of gastrointestinal physiology is the enteric nervous system. This division of the autonomic nervous system is unique in its extensiveness, with neurons distributed from the esophagus to the rectum, and its capability for local information processing. However, the constant motion of the gut, arising from its relative movements in the peritoneal cavity and the peristaltic movements associated with gut motility, as well as the sparse distribution of the neurons constituting the enteric nervous system, has made access and analysis exceedingly challenging. Here, we present the construction and validation of a bioelectronic implant for accessing neural information from the distal colon. Our bioelectronic monitoring system demonstrates real-time electrophysiological recording in response to chemical and mechanical distension under anesthesia and to feeding and stress in freely-moving animals. Direct access to the communication pathways of the enteric nervous system paves the way for neuromodulation strategies targeting the gut – brain axis.
- 20 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 10240
Open AccessImplantable bioelectronics for gut electrophysiology
A major regulator of gastrointestinal physiology is the enteric nervous system. This division of the autonomic nervous system is unique in its extensiveness, with neurons distributed from the esophagus to the rectum, and its capability for local information processing. However, the constant motion of the gut, arising from its relative movements in the peritoneal cavity and the peristaltic movements associated with gut motility, as well as the sparse distribution of the neurons constituting the enteric nervous system, has made access and analysis exceedingly challenging. Here, we present the construction and validation of a bioelectronic implant for accessing neural information from the distal colon. Our bioelectronic monitoring system demonstrates real-time electrophysiological recording in response to chemical and mechanical distension under anesthesia and to feeding and stress in freely-moving animals. Direct access to the communication pathways of the enteric nervous system paves the way for neuromodulation strategies targeting the gut – brain axis.
- Open Access
- 14 August 2025
- Published by Wiley in Advanced Materials
- Vol. 37 (51) , e01985
Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays
Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.
- 14 August 2025
- Published by Wiley in Advanced Materials
- Vol. 37 (51) , e01985
Open AccessAutomated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays
Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.
- Open Access
Bioelectronic platform enables lectin-based enrichment of columnar cell clusters for Barrett’s oesophagus detection
Enriching diagnostically relevant cells from heterogeneous clinical samples is critical for enabling accurate detection and molecular analysis. Bioelectronic platforms offer a promising approach to this challenge by combining selective capture with real-time, label-free monitoring. We focus on Barrett’s oesophagus (BE), a precursor to oesophageal adenocarcinoma (EAC), where current non-endoscopic tools like the capsule-sponge yield samples dominated by background squamous cells, limiting diagnostic sensitivity. We present a bioelectronic enrichment platform that selectively captures and thermally releases columnar cells from capsule-sponge samples. The system employs a ring microelectrode array functionalised with the lectin ECA—identified here as a selective marker of columnar cells in BE—and coated with a thermo-responsive PEDOT-pNIPAAam polymer. Capture and detachment of cells were monitored using both electrochemical impedance and optical imaging, enabling real-time, label-free feedback. Applied to clinical samples, our platform enriched viable columnar cells, enhancing downstream molecular readouts. This approach integrates seamlessly with non-invasive sampling workflows and expands the utility of bioelectronic tools for early cancer diagnostics.
Open AccessBioelectronic platform enables lectin-based enrichment of columnar cell clusters for Barrett’s oesophagus detection
Enriching diagnostically relevant cells from heterogeneous clinical samples is critical for enabling accurate detection and molecular analysis. Bioelectronic platforms offer a promising approach to this challenge by combining selective capture with real-time, label-free monitoring. We focus on Barrett’s oesophagus (BE), a precursor to oesophageal adenocarcinoma (EAC), where current non-endoscopic tools like the capsule-sponge yield samples dominated by background squamous cells, limiting diagnostic sensitivity. We present a bioelectronic enrichment platform that selectively captures and thermally releases columnar cells from capsule-sponge samples. The system employs a ring microelectrode array functionalised with the lectin ECA—identified here as a selective marker of columnar cells in BE—and coated with a thermo-responsive PEDOT-pNIPAAam polymer. Capture and detachment of cells were monitored using both electrochemical impedance and optical imaging, enabling real-time, label-free feedback. Applied to clinical samples, our platform enriched viable columnar cells, enhancing downstream molecular readouts. This approach integrates seamlessly with non-invasive sampling workflows and expands the utility of bioelectronic tools for early cancer diagnostics.
- Open Access
- 3 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
Recreating the biological steps of viral infection on a cell-free bioelectronic platform to profile viral variants of concern
Viral mutations frequently outpace technologies used to detect harmful variants. Given the continual emergence of SARS-CoV-2 variants, platforms that can identify the presence of a virus and its propensity for infection are needed. Our electronic biomembrane sensing platform recreates distinct SARS-CoV-2 host cell entry pathways and reports the progression of entry as electrical signals. We focus on two necessary entry processes mediated by the viral Spike protein: virus binding and membrane fusion, which can be distinguished electrically. We find that closely related variants of concern exhibit distinct fusion signatures that correlate with trends in cell-based infectivity assays, allowing us to report quantitative differences in their fusion characteristics and hence their infectivity potentials. We use SARS-CoV-2 as our prototype, but we anticipate that this platform can extend to other enveloped viruses and cell lines to quantifiably assess virus entry.
- 3 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
Open AccessRecreating the biological steps of viral infection on a cell-free bioelectronic platform to profile viral variants of concern
Viral mutations frequently outpace technologies used to detect harmful variants. Given the continual emergence of SARS-CoV-2 variants, platforms that can identify the presence of a virus and its propensity for infection are needed. Our electronic biomembrane sensing platform recreates distinct SARS-CoV-2 host cell entry pathways and reports the progression of entry as electrical signals. We focus on two necessary entry processes mediated by the viral Spike protein: virus binding and membrane fusion, which can be distinguished electrically. We find that closely related variants of concern exhibit distinct fusion signatures that correlate with trends in cell-based infectivity assays, allowing us to report quantitative differences in their fusion characteristics and hence their infectivity potentials. We use SARS-CoV-2 as our prototype, but we anticipate that this platform can extend to other enveloped viruses and cell lines to quantifiably assess virus entry.
- Open Access
- 1 December 2023
- Published by Wiley in Advanced Science
- Vol. 11 (27) , e2304301
Microelectrode Arrays Measure Blocking of Voltage‐Gated Calcium Ion Channels on Supported Lipid Bilayers Derived from Primary Neurons
Drug studies targeting neuronal ion channels are crucial to understand neuronal function and develop therapies for neurological diseases. The traditional method to study neuronal ion‐channel activities heavily relies on the whole‐cell patch clamp as the industry standard. However, this technique is both technically challenging and labour‐intensive, while involving the complexity of keeping cells alive with low throughput. Therefore, the shortcomings are limiting the efficiency of ion‐channel‐related neuroscience research and drug testing. Here, this work reports a new system of integrating neuron membranes with organic microelectrode arrays (OMEAs) for ion‐channel‐related drug studies. This work demonstrates that the supported lipid bilayers (SLBs) derived from both neuron‐like (neuroblastoma) cells and primary neurons are integrated with OMEAs for the first time. The increased expression of voltage‐gated calcium (CaV) ion channels on differentiated SH‐SY5Y SLBs compared to non‐differentiated ones is sensed electrically. Also, dose‐response of the CaV ion‐channel blocking effect on primary cortical neuronal SLBs from rats is monitored. The dose range causing ion channel blocking is comparable to literature. This system overcomes the major challenges from traditional methods (e.g., patch clamp) and showcases an easy‐to‐test, rapid, ultra‐sensitive, cell‐free, and high‐throughput platform to monitor dose‐dependent ion‐channel blocking effects on native neuronal membranes.
- 1 December 2023
- Published by Wiley in Advanced Science
- Vol. 11 (27) , e2304301
Open AccessMicroelectrode Arrays Measure Blocking of Voltage‐Gated Calcium Ion Channels on Supported Lipid Bilayers Derived from Primary Neurons
Drug studies targeting neuronal ion channels are crucial to understand neuronal function and develop therapies for neurological diseases. The traditional method to study neuronal ion‐channel activities heavily relies on the whole‐cell patch clamp as the industry standard. However, this technique is both technically challenging and labour‐intensive, while involving the complexity of keeping cells alive with low throughput. Therefore, the shortcomings are limiting the efficiency of ion‐channel‐related neuroscience research and drug testing. Here, this work reports a new system of integrating neuron membranes with organic microelectrode arrays (OMEAs) for ion‐channel‐related drug studies. This work demonstrates that the supported lipid bilayers (SLBs) derived from both neuron‐like (neuroblastoma) cells and primary neurons are integrated with OMEAs for the first time. The increased expression of voltage‐gated calcium (CaV) ion channels on differentiated SH‐SY5Y SLBs compared to non‐differentiated ones is sensed electrically. Also, dose‐response of the CaV ion‐channel blocking effect on primary cortical neuronal SLBs from rats is monitored. The dose range causing ion channel blocking is comparable to literature. This system overcomes the major challenges from traditional methods (e.g., patch clamp) and showcases an easy‐to‐test, rapid, ultra‐sensitive, cell‐free, and high‐throughput platform to monitor dose‐dependent ion‐channel blocking effects on native neuronal membranes.
- Open Access
- 14 November 2023
- Published by Springer Nature in Research Square
Infection-on-a-chip for viral entry modeling
Reassembling cell membranes on functional supports can facilitate sensing and studying biorecognition events at the cell surface. Here, we introduce a bioelectrical sensing platform on which biomimetic supported lipid bilayers (SLBs) are assembled and electrical signals are used to detect distinct SARS-CoV-2 virus entry pathways. By recreating the host microenvironmental signals, we were able to initiate and monitor fusion events between SLBs and Spike-decorated virus pseudoparticles (VPPs) via changes in membrane resistance using electrochemical impedance spectroscopy (EIS) and confirm independently by total internal reflection microscope (TIRF). EIS data indicated that fluctuations in resistance vary depending on the VPP/SLB interactions (i.e. binding versus fusion) and our sensing platform can distinguish between the two events. We show that this sensing platform offers complete control over components presented, allows for the SLB to model either the host cell or viral surfaces, and can distinguish between virus variants with different fusogenicities. Though SARS-CoV-2 VPPs and biomimetic SLBs serve as a model system, we anticipate that the full capacity of this platform can be realized by expanding to other enveloped viruses and different cell lines to quantifiably explore virus/host interactions, which can be tuned to mimic the membrane environment of a particular host.
- 14 November 2023
- Published by Springer Nature in Research Square
Open AccessInfection-on-a-chip for viral entry modeling
Reassembling cell membranes on functional supports can facilitate sensing and studying biorecognition events at the cell surface. Here, we introduce a bioelectrical sensing platform on which biomimetic supported lipid bilayers (SLBs) are assembled and electrical signals are used to detect distinct SARS-CoV-2 virus entry pathways. By recreating the host microenvironmental signals, we were able to initiate and monitor fusion events between SLBs and Spike-decorated virus pseudoparticles (VPPs) via changes in membrane resistance using electrochemical impedance spectroscopy (EIS) and confirm independently by total internal reflection microscope (TIRF). EIS data indicated that fluctuations in resistance vary depending on the VPP/SLB interactions (i.e. binding versus fusion) and our sensing platform can distinguish between the two events. We show that this sensing platform offers complete control over components presented, allows for the SLB to model either the host cell or viral surfaces, and can distinguish between virus variants with different fusogenicities. Though SARS-CoV-2 VPPs and biomimetic SLBs serve as a model system, we anticipate that the full capacity of this platform can be realized by expanding to other enveloped viruses and different cell lines to quantifiably explore virus/host interactions, which can be tuned to mimic the membrane environment of a particular host.
- Open Access
Recreating the Biological Steps of Viral Infection on a Bioelectronic Platform to Profile Viral Variants of Concern
Viral mutation rates frequently outpace the development of technologies used to detect and identify harmful variants; for SARS Coronavirus-2 (SARS-CoV-2), these are called variants of concern (VOC). Given the continual emergence of VOC, there is a critical need to develop platforms that can identify the presence of a virus and readily identify its propensity for infection. We present an electronic biomembrane sensing platform that recreates the multifaceted and sequential biological cues that give rise to distinct SARS-CoV-2 virus host cell entry pathways and reports the progression of entry steps of these pathways as electrical signals. Within these electrical signals, two necessary entry processes mediated by the viral Spike protein, virus binding and membrane fusion, can be distinguished. Remarkably, we find that closely related VOC exhibit distinct fusion signatures that correlate with trends reported in cell-based infectivity assays, allowing us to report quantitative differences in fusion characteristics among them that inform their infectivity potentials. This cell-free biomimetic infection platform also has a virus-free option that equally reports infectivity potential of the Spike proteins. We used SARS-CoV-2 as our prototype, but we anticipate that this platform will extend to other enveloped viruses and cell lines to quantifiably explore virus/host interactions. This advance should aid in faster determination of entry characteristics and fusogenicities of future VOC, necessary for rapid response.
Open AccessRecreating the Biological Steps of Viral Infection on a Bioelectronic Platform to Profile Viral Variants of Concern
Viral mutation rates frequently outpace the development of technologies used to detect and identify harmful variants; for SARS Coronavirus-2 (SARS-CoV-2), these are called variants of concern (VOC). Given the continual emergence of VOC, there is a critical need to develop platforms that can identify the presence of a virus and readily identify its propensity for infection. We present an electronic biomembrane sensing platform that recreates the multifaceted and sequential biological cues that give rise to distinct SARS-CoV-2 virus host cell entry pathways and reports the progression of entry steps of these pathways as electrical signals. Within these electrical signals, two necessary entry processes mediated by the viral Spike protein, virus binding and membrane fusion, can be distinguished. Remarkably, we find that closely related VOC exhibit distinct fusion signatures that correlate with trends reported in cell-based infectivity assays, allowing us to report quantitative differences in fusion characteristics among them that inform their infectivity potentials. This cell-free biomimetic infection platform also has a virus-free option that equally reports infectivity potential of the Spike proteins. We used SARS-CoV-2 as our prototype, but we anticipate that this platform will extend to other enveloped viruses and cell lines to quantifiably explore virus/host interactions. This advance should aid in faster determination of entry characteristics and fusogenicities of future VOC, necessary for rapid response.
- Open Access
- 8 June 2023
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 10 (9) , 3589-3600
3D organic bioelectronics for electrical monitoring of human adult stem cells
Three-dimensional in vitro stem cell models have enabled a fundamental understanding of cues that direct stem cell fate. While sophisticated 3D tissues can be generated, technology that can accurately monitor these complex models in a high-throughput and non-invasive manner is not well adapted. Here we show the development of 3D bioelectronic devices based on the electroactive polymer poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate)–(PEDOT:PSS) and their use for non-invasive, electrical monitoring of stem cell growth. We show that the electrical, mechanical and wetting properties as well as the pore size/architecture of 3D PEDOT:PSS scaffolds can be fine-tuned simply by changing the processing crosslinker additive. We present a comprehensive characterization of both 2D PEDOT:PSS thin films of controlled thicknesses, and 3D porous PEDOT:PSS structures made by the freeze-drying technique. By slicing the bulky scaffolds we generate homogeneous, porous 250 μm thick PEDOT:PSS slices, constituting biocompatible 3D constructs able to support stem cell cultures. These multifunctional slices are attached on indium-tin oxide substrates (ITO) with the help of an electrically active adhesion layer, enabling 3D bioelectronic devices with a characteristic and reproducible, frequency dependent impedance response. This response changes drastically when human adipose derived stem cells (hADSCs) grow within the porous PEDOT:PSS network as revealed by fluorescence microscopy. The increase of cell population within the PEDOT:PSS porous network impedes the charge flow at the interface between PEDOT:PSS and ITO, enabling the interface resistance (R1) to be used as a figure of merit to monitor the proliferation of stem cells. The non-invasive monitoring of stem cell growth allows for the subsequent differentiation 3D stem cell cultures into neuron like cells, as verified by immunofluorescence and RT-qPCR measurements. The strategy of controlling important properties of 3D PEDOT:PSS structures simply by altering processing parameters can be applied for development of a number of stem cell in vitro models as well as stem cell differentiation pathways. We believe the results presented here will advance 3D bioelectronic technology for both fundamental understanding of in vitro stem cell cultures as well as the development of personalized therapies.
- 8 June 2023
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 10 (9) , 3589-3600
Open Access3D organic bioelectronics for electrical monitoring of human adult stem cells
Three-dimensional in vitro stem cell models have enabled a fundamental understanding of cues that direct stem cell fate. While sophisticated 3D tissues can be generated, technology that can accurately monitor these complex models in a high-throughput and non-invasive manner is not well adapted. Here we show the development of 3D bioelectronic devices based on the electroactive polymer poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate)–(PEDOT:PSS) and their use for non-invasive, electrical monitoring of stem cell growth. We show that the electrical, mechanical and wetting properties as well as the pore size/architecture of 3D PEDOT:PSS scaffolds can be fine-tuned simply by changing the processing crosslinker additive. We present a comprehensive characterization of both 2D PEDOT:PSS thin films of controlled thicknesses, and 3D porous PEDOT:PSS structures made by the freeze-drying technique. By slicing the bulky scaffolds we generate homogeneous, porous 250 μm thick PEDOT:PSS slices, constituting biocompatible 3D constructs able to support stem cell cultures. These multifunctional slices are attached on indium-tin oxide substrates (ITO) with the help of an electrically active adhesion layer, enabling 3D bioelectronic devices with a characteristic and reproducible, frequency dependent impedance response. This response changes drastically when human adipose derived stem cells (hADSCs) grow within the porous PEDOT:PSS network as revealed by fluorescence microscopy. The increase of cell population within the PEDOT:PSS porous network impedes the charge flow at the interface between PEDOT:PSS and ITO, enabling the interface resistance (R1) to be used as a figure of merit to monitor the proliferation of stem cells. The non-invasive monitoring of stem cell growth allows for the subsequent differentiation 3D stem cell cultures into neuron like cells, as verified by immunofluorescence and RT-qPCR measurements. The strategy of controlling important properties of 3D PEDOT:PSS structures simply by altering processing parameters can be applied for development of a number of stem cell in vitro models as well as stem cell differentiation pathways. We believe the results presented here will advance 3D bioelectronic technology for both fundamental understanding of in vitro stem cell cultures as well as the development of personalized therapies.
- Open Access
- 3 May 2023
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 9 (6) , 3632-3642
Multiparametric Sensing of Outer Membrane Vesicle-Derived Supported Lipid Bilayers Demonstrates the Specificity of Bacteriophage Interactions
The use of bacteriophages, viruses that specifically infect bacteria, as antibiotics has become an area of great interest in recent years as the effectiveness of conventional antibiotics recedes. The detection of phage interactions with specific bacteria in a rapid and quantitative way is key for identifying phages of interest for novel antimicrobials. Outer membrane vesicles (OMVs) derived from Gram-negative bacteria can be used to make supported lipid bilayers (SLBs) and therefore in vitro membrane models that contain naturally occurring components of the bacterial outer membrane. In this study, we employed Escherichia coli OMV derived SLBs and use both fluorescent imaging and mechanical sensing techniques to show their interactions with T4 phage. We also integrate these bilayers with microelectrode arrays (MEAs) functionalized with the conducting polymer PEDOT:PSS and show that the pore forming interactions of the phages with the SLBs can be monitored using electrical impedance spectroscopy. To highlight our ability to detect specific phage interactions, we also generate SLBs using OMVs derived from Citrobacter rodentium, which is resistant to T4 phage infection, and identify their lack of interaction with the phage. The work presented here shows how interactions occurring between the phages and these complex SLB systems can be monitored using a range of experimental techniques. We believe this approach can be used to identify phages that work against bacterial strains of interest, as well as more generally to monitor any pore forming structure (such as defensins) interacting with bacterial outer membranes, and thus aid in the development of next generation antimicrobials.
- 3 May 2023
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 9 (6) , 3632-3642
Open AccessMultiparametric Sensing of Outer Membrane Vesicle-Derived Supported Lipid Bilayers Demonstrates the Specificity of Bacteriophage Interactions
The use of bacteriophages, viruses that specifically infect bacteria, as antibiotics has become an area of great interest in recent years as the effectiveness of conventional antibiotics recedes. The detection of phage interactions with specific bacteria in a rapid and quantitative way is key for identifying phages of interest for novel antimicrobials. Outer membrane vesicles (OMVs) derived from Gram-negative bacteria can be used to make supported lipid bilayers (SLBs) and therefore in vitro membrane models that contain naturally occurring components of the bacterial outer membrane. In this study, we employed Escherichia coli OMV derived SLBs and use both fluorescent imaging and mechanical sensing techniques to show their interactions with T4 phage. We also integrate these bilayers with microelectrode arrays (MEAs) functionalized with the conducting polymer PEDOT:PSS and show that the pore forming interactions of the phages with the SLBs can be monitored using electrical impedance spectroscopy. To highlight our ability to detect specific phage interactions, we also generate SLBs using OMVs derived from Citrobacter rodentium, which is resistant to T4 phage infection, and identify their lack of interaction with the phage. The work presented here shows how interactions occurring between the phages and these complex SLB systems can be monitored using a range of experimental techniques. We believe this approach can be used to identify phages that work against bacterial strains of interest, as well as more generally to monitor any pore forming structure (such as defensins) interacting with bacterial outer membranes, and thus aid in the development of next generation antimicrobials.