ADAmin Davoudi

Amin Davoudi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Amin Davoudi has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Elham Shadmehr

    Preventive Restorative Dental Sciences Department, Endodontics Division, University of California San Francisco, San Francisco, USA

    4 shared publications
  • Farahnaz Nejatidanesh

    Dental Materials Research Center, Dental Research Institute Isfahan University of Medical Sciences Isfahan Iran

    2 shared publications
  • Ghazal Savabi

    Dental Materials Research Center, Dental Research Institute Isfahan University of Medical Sciences Isfahan Iran

    2 shared publications
  • Mahtab Tabesh

    Baker Heart and Diabetes Institute Melbourne Victoria Australia

    2 shared publications
  • Masoud Saatchi

    Dental Research Center, Department of Endodontics, Dental Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran

    2 shared publications
  • Nima Damoon Sarmast

    Department of Periodontics and Dental Hygiene, School of Dentistry, University of Texas Health Science Center at Houston, Houston, Texas, USA

    2 shared publications

Latest Publications

  • Open Access

    The effect of different cleansing methods for removing temporary cement on the tensile bond force of permanently cemented implant‐supported metal copings: An in vitro study

    by Behnaz Ebadian, Mohammad Jowkar, Amin Davoudi, Amirhossein Fathi, Mohsen Ziaei, Einar Berg

    Objectives: Complete cleaning of temporary cement before permanent cementation of cement‐retained implant‐supported prosthesis (CISP) when recementing the crown is critical. This study evaluated the effect of different cleaning methods for removing traces of temporary cement on the final tensile bond force (TBF) of CISP recemented with resin cement.Materials and Methods: Seventy computer‐aided design/computer‐aided manufacturing metal implant‐supported copings were prepared and distributed into seven groups (N = 10). Copings of six groups (60 samples) were cemented with temporary cement with eugenol and subjected to 5000 thermocycling. After debonding by a universal testing machine, the internal surfaces of the copings were cleaned using one of the six following methods: 1‐an ultrasonic water bath (UW), 2‐sandblasting, then washing with water (SW), 3‐sandblasting and an ultrasonic water bath (SUW), 4‐an ultrasonic isopropyl alcohol bath (UA), 5‐sandblasting, then washing with isopropyl alcohol (SA) or 6‐sandblasting and an ultrasonic isopropyl alcohol bath (SUA). Then the subjects were subsequently cemented by dual‐cure self‐adhesive resin cement. In the seventh group (control, N = 10), the copings were cemented by dual‐cure self‐adhesive resin cement without the temporization phase. The TBF was tested using a universal testing machine with a cross‐head speed of 1 mm/min. Two‐way analysis of variance (ANOVA) and post‐hoc Tamhane tests were used for statistical analysis at a significance level of α = .05.Results: The maximum mean of TBF value was observed in SUA group (845 ± 203 N), and the minimum was observed in the temporary cement group (49 ± 20 N). All groups which were cleaned with isopropyl alcohol showed significantly higher TBF values compared with those cleaned with water.Conclusions: Cleaning of the inner surface of metal copings after debonding with sandblasting and isopropyl alcohol results in the highest value of TBF by eliminating the effect of remaining eugenol and removing traces of temporary cements.


  • Marginal Accuracy of Lithium Disilicate Full‐Coverage Single Crowns Made by Direct and Indirect Digital or Conventional Workflows: A Systematic Review and Meta‐Analysis

    by Mahtab Tabesh, Farahnaz Nejatidanesh, Ghazal Savabi, Amin Davoudi, Omid Savabi

    Purpose: Several studies have compared digital intraoral scanners and conventional impressions. The accuracy of these two methods in terms of marginal accuracy of lithium disilicate crowns is not well‐established, yet. The purpose of this study was to systematically review available publications on marginal fit of single‐unit, full‐coverage, tooth‐supported lithium disilicate restorations.Methods: Pubmed, Web of Science, Cochrane, EMBASE, and Scopus were electronically searched along with a manual search. After critical appraisal, data from selected studies were extracted and mean marginal difference with a 95% confidence interval was calculated. Meta‐analysis of the collected data was conducted using STATA software.Results: The meta‐analysis revealed similar marginal gap values in intraoral scanners with conventional groups (p>0.05) and in intraoral scanners with extraoral canners (p>0.05).Conclusion: No significant difference was seen between digital and conventional impressions or intra‐ and extraoral scanners for marginal accuracy of lithium disilicate crowns.


  • Open Access

    Evaluation of Antimicrobial Efficacy of Calcium Hypochlorite as an Endodontic Irrigant on a Mixed-culture Biofilm: An Ex vivo Study

    by Elham Shadmehr, Amin Davoudi, Nima Damoon Sarmast, Masoud Saatchi

    Calcium hypochlorite (CH) has been recently suggested as an endodontic irrigant. The aim of this investigation was to evaluate the antimicrobial efficacy of CH compared to sodium hypochlorite (NaOCl) and chlorhexidine (CHX) against multispecies biofilm in surface and deep dentinal tubules. Minimal inhibitory concentration (MIC) of irrigant agents was assessed using a microdilution method. One hundred and twenty of human maxillary incisor teeth were prepared and infected with suspension of Entrococcus faecalis, Fusobacterium nucleatum and Prevotella intermedia in an anaerobic jar for 7 days. Depending on irrigation solutions, specimens were divided into 4 groups (n=30); group 1: 2% CHX, group 2: 5.25% sodium hypochlorite, group 3: 5% calcium hypochlorite, group 4: positive control (normal saline (NS)). Fifteen remained specimens were used as negative control. Surviving bacteria were sampled before (S1) and after irrigation from surface (S2) and deep (S3) dentin. The medium turbidity was visualized with spectrophotometry. Data were analyzed using analysis of variance followed by Tukey post hoc test (α=0.05). The MIC of CH against E. faecalis, F. nucleatum and P. intermedia was 25, 8 and 7.5 µg/mL respectively. There were no significant differences in S1 among the test groups. Moreover, 2% CHX and 5% CH had significantly lower medium turbidity at both S2 and S3, in comparison with 5.25% NaOCl (P=0.018 and 0.031, respectively). But there were no significant differences between 2% CHX and 5% CH at both S2 and S3 (P=0.862 and 0.978, respectively). Under the conditions of this ex vivo study, 5% CH and 2% CHX are more effective than 5.25% NaOCl in the reduction of mixed-culture biofilm.


    • 1 January 2019
      • Vol. 14  (4) , 247-252
    Open Access

    Effect of Phentolamine as Reversal of Soft-Tissue Anesthesia on Post-Endodontic Pain in Patients with Symptomatic Irreversible Pulpitis: A Randomized Clinical Trial.

    by Elham Shadmehr, Masoud Saatchi, Nima Damoon Sarmast, Shervin Bagherieh, Amin Davoudi

    Phentolamine mesylate (OraVerse) is mostly used to reverse soft tissue anesthesia after dental procedures. The aim of the present study was to evaluate the effect of the injection of OraVerse on postoperative pain after root canal treatment in patients with symptomatic irreversible pulpitis. In this randomized single-blind clinical trial study, 100 patients (50 per group) with symptomatic irreversible pulpitis in the first or second mandibular molars, randomly received either OraVerse or sham treatment after a single-visit root canal therapy. Each patient recorded their pain score, using a Heft Parker visual analogue scale, before and after 6, 12, 24, 36, 48, and 72 h of the treatment. They also monitored their soft-tissue anesthesia every 15 min for 5 h. Data were analyzed by t-test and repeated measured ANOVA statistical tests. The level of significance was set at 0.05. Patients who received phentolamine had significantly higher pain scores at 6- and 12-h postoperative intervals compared with those receiving sham treatment (P=0.01 and P=0.00 respectively). Consumption of analgesics in OraVerse group was significantly higher than that of the sham group (P=0.48). Although phentolamine accelerated the reversal of normal soft tissue sensation after the dental visit, it increased postoperative pain in patients suffering from symptomatic irreversible pulpitis, which may limit phentolamine administration in this group.

  • Open Access

    Hard tissue reaction to mineral trioxide aggregate and experimental root-end filling material in guinea pig mandibles

    by Ali Akhavan, Peter Parashos, Sayed Mohammad Razavi, Amin Davoudi, Elham Shadmehr


  • Open Access

    Effect of Using Nano and Micro Airborne Abrasive Particles on Bond Strength of Implant Abutment to Prosthesis

    by Mansour Rismanchian, Amin Davoudi, Elham Shadmehr

    Connecting prostheses to the implant abutments has become a concern and achieving a satisfactory retention has been focused in cement-retention prostheses recently. Sandblasting is a method to make a roughened surface for providing more retention. The aim of this study was to compare effects of nano and micro airborne abrasive particles (ABAP) in roughening surface of implant abutments and further retention of cemented copings. Thirty Xive abutments and analogues (4.5 D GH1) were mounted vertically in self-cured acrylic blocks. Full metal Ni-Cr copings with a loop on the top were fabricated with appropriate marginal adaptation for each abutment. All samples were divided into 3 groups: first group (MPS) was sandblasted with 50 µm Al2O3 micro ABAP, second group (NSP) was sandblasted with 80 nm Al2O3 nano ABAP, and the third group (C) was assumed as control. The samples were cemented with provisional cement (Temp Bond) and tensile bond strength of cemented copings was evaluated by a universal testing machine after thermic cycling. The t test for independent samples was used for statistical analysis by SPSS software (version 15) at the significant level of 0.05. Final result showed significant difference among all groups (p<0.001) and MPS manifested the highest mean retention (207.88±45.61 N) with significant difference among other groups (p<0.001). The control group showed the lowest bond strength as predicted (48.95±10.44 N). Using nano or micro ABAP is an efficient way for increasing bond strengths significantly, but it seems that micro ABAP was more effective.


  • Open Access

    Posterior open occlusion management by registration of overlay removable partial denture: A clinical report

    by Amin Davoudi, Saeid Nosouhian, Mohammad Derhami

    This clinical report describes prosthetic rehabilitation of posterior open bite relationship in a patient with several missing teeth and skeletal Class III malocclusion. Primary diagnostic esthetic evaluations were performed by mounting casts in centric relation and estimating lost vertical dimension of occlusion. Exclusive treatments were designated by applying overlay removable partial denture with external attachment systems for higher retentions.