MTMelina Tourni

Melina Tourni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Melina Tourni has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electromechanical activation and recovery wave imaging for pediatric mitral valve disease characterization

    by Melina Tourni, Christina Proestaki, Seungyeon Julia Han, Johanna B. Tonko, Mary Kucinski, Rachel Weber, Rosalia Minyety, Yaffa Wolicki, Youssef A. Elnabawi, Aikaterini Afentouli, et al.

    Mitral valve (MV) disease, particularly MV prolapse (MVP) and mitral regurgitation (MR), affects 2 to 5% of the population and poses a substantial arrhythmogenic risk, with 43% of MVP patients developing arrhythmias. Although less common in children, the absence of comorbidities can uniquely isolate early electromechanical alterations that may elucidate mechanisms later contributing to arrhythmic risk and devastating effects such as sudden cardiac death. Conventional echocardiography lacks sensitivity for MV electromechanics, motivating advanced approaches. We introduce Electromechanical Wave Imaging (EWI), a high-frame-rate echocardiography modality, to map MV-complex activation and diastolic recovery in N = 21 MVP, MR, and control pediatric subjects (13.10 ± 4.51 y old, 43% male). A preclinical canine study (n = 3) established EWI’s ability to observe temporally coupled electromechanical wave propagation across the atrioventricular junction through the closed MV-following atrial and preceding ventricular activation (73.0 ms, 60 BPM). MVP patients exhibited significantly delayed left ventricular (LV) activation (76.04 ± 12.51 ms vs. 47.64 ± 2.57 ms in controls, P = 0.0013), primarily in papillary muscles. Both MVP and MR-only subjects exhibited prolonged LV recovery, with MR-only patients showing significantly longer recovery intervals (MR-only: 277.0 ± 27.61 ms, Control: 248.7 ± 10.43 ms, MVP vs. Control: MR-only vs. Control: P = 0.0395). In two arrhythmogenic MVP cases, EWI localized arrhythmic exit sites adjacent to LV papillary muscles, coinciding with regional delayed sinus activation, aligning with invasive electrophysiology. This study demonstrates that atrioventricular valve function dictates cardiac electromechanical function and establishes full-cycle EWI as a transformative tool for diagnosing MV disease electromechanical effects, assessing arrhythmic risk, guiding interventions, and advancing noninvasive cardiac imaging.

  • Open Access

    High volume-rate echocardiography for simultaneous imaging of electromechanical activation and cardiac strain of the whole heart in a single heartbeat in humans

    by Julien Grondin, Hannah J. Schleifer, Rachel Weber, Changhee Lee, Melina Tourni, Elisa E. Konofagou

    Background: Imaging both electrical and mechanical cardiac function can better characterize cardiac disease and improve patient care. Currently, there is no noninvasive technique that can simultaneously image both electrical and mechanical function of the whole heart at the point of care. Here, our aim is to demonstrate that high volume-rate echocardiography can simultaneously map cardiac electromechanical activation and end-systolic cardiac strain of the whole heart in a single heartbeat. Method: A 32x32 ultrasound matrix array connected to four synchronized ultrasound scanners were used for transthoracic high volume-rate imaging (840 volumes/s) in sixteen young volunteers (28.1±4.2 y.o.). An electromechanical activation map of the whole heart and volumetric end-systolic atrial and ventricular strain images were obtained. Results: The whole heart activation sequence was found to be consistent across volunteers and in agreement with previously reported normal electrical activation sequences. The mean electromechanical activation time was 72.6±15.2 ms in the atria, 132.4±19.7 ms in the ventricles and 154.5±19.6 ms in the whole heart. Volumetric right and left atrial as well as right and left ventricular strains were also consistent across all volunteers, with a mean end-systolic global longitudinal strain of 26.8±6.5% in the atria and -16.6±3.4% in the ventricles. Conclusions: This initial feasibility study demonstrates that noninvasive high-volume rate imaging of the heart in a single heartbeat is feasible and can provide electromechanical activation and systolic strains simultaneously in all four cardiac chambers. This technique can be further developed and used at the point of care to assist for screening, diagnosis, therapy guidance and follow-up of heart disease patients.


  • Open Access

    Long-term atrial arrhythmia characterization and treatment efficacy evaluation using non-invasive echocardiography-based electromechanical cycle length mapping: a case series

    by Melina Tourni, Rachel Weber, Angelo Biviano, Elisa Konofagou

    Background: Atrial fibrillation (AF) is a prevalent cardiac condition characterized by irregular heart rhythm. Conventional non-invasive diagnostic techniques, while useful, have limitations in providing comprehensive information for treatment planning. To address this gap, electromechanical cycle length mapping (ECLM), a non-invasive echocardiography-based technique, has emerged as a promising approach. Electromechanical cycle length mapping offers quantitative and spatially specific insights into atrial electromechanical activation rate mapping, thereby enhancing our understanding of arrhythmia disease progression in AF patients. Case summary: In this case series, we present two patient cases demonstrating the potential utility of ECLM in monitoring and evaluating treatment responses in atrial arrhythmia. The 1st case involved a 61-year-old male with persistent AF who underwent multiple procedures, including direct current cardioversion (DCCV) and radiofrequency ablation. Over three different DCCV encounters, pre- and post-procedure ECLM scans were performed, and the results showed the localization and incomplete elimination of arrhythmic triggers post-DCCV, which were used as early indicators of AF recurrence. The 2nd case involved a 71-year-old male with paroxysmal AF who also underwent cardioversion and ablation procedures. Electromechanical cycle length mapping imaging demonstrated a progressive reduction and elimination of arrhythmia triggers after each encounter, resulting in long-term maintenance of sinus rhythm. Discussion: The findings from this case series highlight the potential of ECLM as a non-invasive imaging tool for long-term monitoring and evaluating immediate and long-term treatment responses in AF patients. The integration of ECLM with standard echocardiograms holds promise in guiding clinical decisions and improving patient outcomes in managing atrial fibrillation.


  • Electromechanical Cycle Length Mapping for atrial arrhythmia detection and cardioversion success assessment

    by Melina Tourni, Seungyeon Julia Han, Rachel Weber, Mary Kucinski, Elaine Y. Wan, Angelo B. Biviano, Elisa E. Konofagou


  • A New Electromechanical Wave Imaging Dispersion Metric for the Characterization of Ventricular Activation in Different Cardiac Resynchronization Therapy Pacing Schemes

    by Lea Melki, Melina Tourni, Daniel Y. Wang, Rachel Weber, Elaine Y. Wan, Elisa E. Konofagou

    Conventional biventricular (BiV) pacing cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients. Recently, multiple novel CRT delivering technologies such as His-Bundle pacing have been investigated as alternative pacing strategies for optimal treatment benefit. Electromechanical Wave Imaging (EWI), a high frame-rate echocardiography-based modality, is capable of visualizing the change from dyssynchronous activation to resynchronized BiV-paced ventricles in 3D. This proof-of-concept study introduces a new EWI-based dispersion metric to further characterize ventricular activation. Patients with His-Bundle device implantation (n=4), left-bundle branch block (n=10), right-ventricular (RV) pacing (n=10), or BiV pacing (n=15) were imaged, as well as four volunteers in normal sinus rhythm (NSR). EWI successfully mapped the ventricular activation resulting from His-Bundle pacing. Additionally, very similar activation patterns were obtained in the NSR subjects, confirming recovery of physiological activation with His pacing. The dispersion metric was the most sensitive EWI-based metric that identified His pacing as the most efficient treatment (lowest activation time spread), followed by BiV and RV pacing. More specifically, the dispersion metric significantly (p $< $ 0.005) distinguished His pacing from the other two pacing schemes as well as LBBB. The initial findings presented herein indicate that EWI and its new dispersion metric may provide a useful resynchronization evaluation clinical tool in CRT patients under both novel His-Bundle pacing and more conventional BiV pacing strategies.


  • Electromechanical Wave Imaging With Machine Learning for Automated Isochrone Generation

    by Lea Melki, Melina Tourni, Elisa E. Konofagou

    Standard Electromechanical Wave Imaging isochrone generation relies on manual selection of zero-crossing (ZC) locations on incremental strain curves for a number of pixels in the segmented myocardium for each echocardiographic view and patient. When considering large populations, this becomes a time-consuming process, that can be limited by inter-observer variability and operator bias. In this study, we developed and optimized an automated ZC selection algorithm, towards a faster more robust isochrone generation approach. The algorithm either relies on heuristic-based baselines or machine learning classifiers. Manually generated isochrones, previously validated against 3D intracardiac mapping, were considered as ground truth during training and performance evaluation steps. The machine learning models applied herein for the first time were: i) logistic regression; ii) support vector machine (SVM); and iii) Random Forest. The SVM and Random Forest classifiers successfully identified accessory pathways in Wolff-Parkinson-White patients, characterized sinus rhythm in humans, and localized the pacing electrode location in left ventricular paced canines on the resulting isochrones. Nevertheless, the best performing classifier was proven to be Random Forest with a precision rising from 89.5% to 97%, obtained with the voting approach that sets a probability threshold upon ZC candidate selection. Furthermore, the predictivity was not dependent on the type of testing dataset it was applied to, contrary to SVM that exhibited a 5% drop in precision on the canine testing dataset. Finally, these findings indicate that a machine learning approach can reduce user variability and considerably decrease the durations required for isochrone generation, while preserving accurate activation patterns.