CYChao Yang

Chao Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chao Yang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Test of Two Kilo-Amp Linear-Motor Type Flux Pumps With Converged Output Current Over 3.1 kA

    by Wei Wang, Li Zhou, Xingming Wang, Donghui Jiang, Chao Yang, Chenghuai Wu, Shikang Huang, Peng Liu, Fuling Tang, Mengchao Zhang, et al.

    Due to its low energy consumption and cost-effectiveness, contactless charging using flux pumps has emerged as one of the most promising candidates for replacing traditional superconducting DC power supplies. In our previous work, we have successfully developed a kilo-amp linear-motor type flux pump (W. Wang et al., Sep. 2022). In this study, we use two of such kilo-amp linear-motor type flux pumps to perform a convergence test to have reached a total current output of 3.1 kA, which is the highest output record of flux pumps up to this date. One of the two kilo-amp flux pumps was improved with its design, resulting in reduced power consumptions and a smaller volume, while maintaining the same output performance as the previous version (W. Wang et al., Sep. 2022). The parallel connection of the two flux pumps effectively extend the number of parallel superconducting stators, which expected to double the DC output current. The tests are performed in liquid nitrogen at 77 K, a remarkable 3,186 A DC output is recorded on the superconducting load. This paper also demonstrates the use of DC bias coil to modulate the amplitude and direction of pumping currents based on the “four-quadrant” current control method, which enable the flux pumps with bipolar output currents ranging from −3,145 A to +3,186 A. These experiments validate the method of combination modularized kilo-amp flux pumps to reach more than 10 kA output.


  • Magnetic Conduction Structure Design and Charging Test of a Linear-Motor Type Flux Pump for Through-Dewar Excitation of High Temperature Superconducting Motors

    by Yong Lei, Chenling Xiong, Run Long, Zhenxuan Yang, Fuling Tang, Chenghuai Wu, Chao Yang, Peng Liu, Li Zhou, Shikang Huang, et al.

    High temperature superconductivity (HTS) flux pump can be used as the exciter to inject direct current into the superconducting excitation coil of a synchronous motor, without current lead and with low thermal efficiency, which will reduce the cryogenic volume and improve the efficiency of HTS synchronous motor. However, the flux pump has non-negligible thermal impact when it is running continuously for a long time within the cryogenic Dewar, which will cause a heavy heat burden to the cryogenic system. Therefore, based on the linear-motor type flux pump previously invented in our laboratory, this paper improved its magnetic circuit, so that it can introduce the travelling magnetic wave into the Dewar from outside. Firstly, we have used COMSOL Multiphysics to simulate and optimize the waveform of this flux pump. Secondly, we have manufactured the flux pump and magnetic conduction structure, and have tested its performance in liquid nitrogen at 77 K, a pumped DC current of 216 A was measured with a single 12 mm wide YBCO stator. These work have further optimized the linear-motor type flux pump, which provide a contactless static excitation device (CSED) for the 16.9 kW HTS synchronous motor built in our laboratory.


  • Through-Wall Excitation of a Conduction Cooling HTS Magnets by a Linear-Motor Type Flux Pump

    by Yong Lei, Run Long, Hong Li, Chenling Xiong, Chao Yang, Chenghuai Wu, Zhenxuan Yang, Fuling Tang, Wei Wang

    The flux pumps can realize non-contact excitation of high-temperature superconducting (HTS) magnet and eliminate heat leakage caused by current leads. However, earlier proposed flux pump needs to be installed inside the cryostat, which leads to additional heat load to the cryogenic system. Here, we report the successful demonstration of a through-wall linear-motor type flux pump, with its heating parts such as the copper windings completely outside the cryostat, while its generated heat is dissipated in the air and insulated from the cryostat. With an insulation HTS double pancake coil installed in the cryostat and cooled by a G-M cryogenic cooler at 32.6 K, we have demonstrated the injection of direct currents of 42 A into the closed-loop, without the current leads. Thus, the feasibility and reliability of using the linear-motor type flux pump as the power source to excite the HTS magnet through the cryostat is verified, making it possible for future applications such as in MRI and superconducting motors, etc.


  • A Kilo-Amp Linear-Motor Type Flux Pump

    by Wei Wang, Chao Yang, Hang Xu, Hanxin Ye, Zhenxuan Yang, Hong Li, Jiafu Wei, Yingwei Zhu, Chenghuai Wu, Run Long, et al.

    A kilo-amp linear-motor type flux pump with the maximum output DC current exceeding 1610 A had been designed and manufactured. We had optimized the large-current flux pump based from the previous design, and shortened the travelling wavelength of the flux pump, and simulated its magnetic density distribution with COMSOL Multiphysics, and obtained the present design parameters after analysis. We had placed 12 superconducting single loops side by side in the air gaps on both sides of the flux pump, and had used the flux pump to charge them. We had applied different magnetic flux density in the air gap, the maximum DC output current of the flux pump was measured at 1619 A in the liquid nitrogen at 77 K. We have carried out theoretical analysis on the direction of the pumped current on both sides of the flux pump, while had changed the polarities of the DC windings to make sure that the current directions on both sides are the same. Comparing with the traditional superconducting power supply of the same output current level, this flux pump had not only eliminated the current leads, but also reduces the cost, size and energy consumption of the power source by at least one order. Finally, we designed the prototype of the kilo-amp linear-motor type flux pump to measure the critical current of the superconducting cables.