Gabriel Durán Cardenás
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gabriel Durán Cardenás has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Arnaud Dufour
French National Space Agency (CNES), Toulouse, France
1 shared publication- Arto Javanainen
Department of Physics, University of Jyvskyl, Jyvskyl, Finland
1 shared publication B. Forgerit
Alter Technology France, Toulouse, France
1 shared publication- Bendy Tanios
ALTER Technology France TV Nord, Ramonville-Saint-Agne, France
1 shared publication Christian Poivey
ESA ESTEC, Noordwijk, The Netherlands
1 shared publication- Emmanuel Marcault
CEA, CEA Tech Occitanie
1 shared publication
Latest Publications
- Open Access
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (4) , 667-677
Proton Direct Ionization in Sub-Micron Technologies: Test Methodologies and Modeling
Two different low energy proton (LEP) test methods, one with quasi-monoenergetic and the other with very wide proton beam energy spectra, have been studied. The two test methodologies have been applied to devices that were suggested from prior heavy-ion tests to be sensitive to proton direct ionization (PDI). The advantages and disadvantages of the two test methods are discussed. The test method using quasi-monoenergetic beams requires device preparation and high energy resolution beams, but delivers results that can be interpreted directly and can be used in various soft error rate (SER) calculation methods. The other method, using a heavily degraded high energy proton beam, requires little to no device preparation but more efforts on the beam characterization, and is confined to a specific SER method. While both methods deliver comparable estimates on the SER, the relatively complex determination of the beam characteristics in the degraded beam method makes it less straightforward to use. This work furthers presents a method to extract PDI sensitive volume parameters from degraded high energy proton beam cross-section data. This method extends the use of a previously published method to the degraded high energy beam LEP testing method.
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (4) , 667-677
Open AccessProton Direct Ionization in Sub-Micron Technologies: Test Methodologies and Modeling
Two different low energy proton (LEP) test methods, one with quasi-monoenergetic and the other with very wide proton beam energy spectra, have been studied. The two test methodologies have been applied to devices that were suggested from prior heavy-ion tests to be sensitive to proton direct ionization (PDI). The advantages and disadvantages of the two test methods are discussed. The test method using quasi-monoenergetic beams requires device preparation and high energy resolution beams, but delivers results that can be interpreted directly and can be used in various soft error rate (SER) calculation methods. The other method, using a heavily degraded high energy proton beam, requires little to no device preparation but more efforts on the beam characterization, and is confined to a specific SER method. While both methods deliver comparable estimates on the SER, the relatively complex determination of the beam characteristics in the degraded beam method makes it less straightforward to use. This work furthers presents a method to extract PDI sensitive volume parameters from degraded high energy proton beam cross-section data. This method extends the use of a previously published method to the degraded high energy beam LEP testing method.
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (10) , 2488-2495
Heavy-Ion Testing Method and Results of Normally OFF GaN-Based High-Electron-Mobility Transistor
Gallium nitride (GaN) power switches are promising devices for power conversion applications because this new technology enables the design of power converters with higher efficiency and reduced size than those achievable with conventional silicon devices. For space applications, normally-OFF devices are mandatory to avoid potential current shoot through during startup or loss of power control. The use of these devices in space environment shall be carefully considered with respect to natural radiation and especially under heavy-ion impact that can induce the burnout of the device known as single-event effect (SEE) failure. Therefore, radiation hardness evaluation of GaN devices is of prime interest. Another important parameter affecting GaN power device reliability is the current collapse or dynamic $R_{\mathrm{\scriptscriptstyle ON}}$ since in particular functioning condition, the device can generate extra losses that may lead to failure. Five commercial off-the-shelf (COTS) GaN high-electron-mobility transistor (HEMT) references were selected and tested under heavy ions. This article presents first the testing methodology and device preparation used for heavy-ion test campaign. Then observations from the irradiation run are presented and discussed. At last, a potential dynamic $R_{\mathrm{\scriptscriptstyle ON}}$ issue with respect to heavy-ion safe operating area (SOA) of one reference is highlighted.
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (10) , 2488-2495
Heavy-Ion Testing Method and Results of Normally OFF GaN-Based High-Electron-Mobility Transistor
Gallium nitride (GaN) power switches are promising devices for power conversion applications because this new technology enables the design of power converters with higher efficiency and reduced size than those achievable with conventional silicon devices. For space applications, normally-OFF devices are mandatory to avoid potential current shoot through during startup or loss of power control. The use of these devices in space environment shall be carefully considered with respect to natural radiation and especially under heavy-ion impact that can induce the burnout of the device known as single-event effect (SEE) failure. Therefore, radiation hardness evaluation of GaN devices is of prime interest. Another important parameter affecting GaN power device reliability is the current collapse or dynamic $R_{\mathrm{\scriptscriptstyle ON}}$ since in particular functioning condition, the device can generate extra losses that may lead to failure. Five commercial off-the-shelf (COTS) GaN high-electron-mobility transistor (HEMT) references were selected and tested under heavy ions. This article presents first the testing methodology and device preparation used for heavy-ion test campaign. Then observations from the irradiation run are presented and discussed. At last, a potential dynamic $R_{\mathrm{\scriptscriptstyle ON}}$ issue with respect to heavy-ion safe operating area (SOA) of one reference is highlighted.