Masanobu Yoshikawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Masanobu Yoshikawa has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Masataka Murakami
Toray Research Center Inc. Otsu Japan
4 shared publicationsYasuhiko Fujita
Toray Research Center Inc. Otsu Japan
2 shared publications- Atsushi Hashimoto
Department of Clinical Pharmacology, Tokai University School of Medicine, Isehara, Kanagawa 259-1143, Japan
1 shared publication Junichiro Samejima
Toray Research Center, Inc. Otsu Shiga Japan
1 shared publicationJunichiro Sameshima
Toray Research Center Inc. Otsu Japan
1 shared publicationKana Mitsuzawa
Toray Research Center, Inc. Otsu Shiga Japan
1 shared publication
Latest Publications
- Open Access
- 30 April 2026
- Published by Springer Nature
- p. C1
Correction to: Advanced Optical Spectroscopy Techniques for Semiconductors
- 30 April 2026
- Published by Springer Nature
- p. C1
Open AccessCorrection to: Advanced Optical Spectroscopy Techniques for Semiconductors
- 1 December 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (3) , 473-480
Stress Characterization of Crystal Junction of a Mosaic Diamond Substrate (an Approximately 4 cm 2 ) Using Near‐Field Optical Raman Microscopy
We measured the Raman spectra of a commercially available mosaic diamond substrate using both far‐field (confocal) and near‐field Raman microscopy (SNOM). Although the mosaic diamond substrate is optically transparent, it contains a junction approximately 40 μm wide. Raman measurements revealed the presence of strong compressive and tensile stresses on the order of GPa within the junction region. Analysis of the Raman linewidth indicates that the junction comprises three distinct layers: melting, adhesive, and melting layers. The compressive and tensile stresses measured by SNOM were at least twice as large as those obtained with far‐field Raman microscopy near the junction. This discrepancy is attributed to the different probing depths and spatial resolutions of the two techniques. Based on a simple edge‐force model, we explain the large compressive and tensile stress distributions observed in the vicinity of the junction. Our results indicate that stresses are distributed inhomogeneously not only within the junction of the mosaic diamond crystal but also throughout the thickness of the crystal, from the substrate bottom to the surface.
- 1 December 2025
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (3) , 473-480
Stress Characterization of Crystal Junction of a Mosaic Diamond Substrate (an Approximately 4 cm 2 ) Using Near‐Field Optical Raman Microscopy
We measured the Raman spectra of a commercially available mosaic diamond substrate using both far‐field (confocal) and near‐field Raman microscopy (SNOM). Although the mosaic diamond substrate is optically transparent, it contains a junction approximately 40 μm wide. Raman measurements revealed the presence of strong compressive and tensile stresses on the order of GPa within the junction region. Analysis of the Raman linewidth indicates that the junction comprises three distinct layers: melting, adhesive, and melting layers. The compressive and tensile stresses measured by SNOM were at least twice as large as those obtained with far‐field Raman microscopy near the junction. This discrepancy is attributed to the different probing depths and spatial resolutions of the two techniques. Based on a simple edge‐force model, we explain the large compressive and tensile stress distributions observed in the vicinity of the junction. Our results indicate that stresses are distributed inhomogeneously not only within the junction of the mosaic diamond crystal but also throughout the thickness of the crystal, from the substrate bottom to the surface.
- 25 May 2024
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 55 (9) , 982-988
Anisotropic stress observation of 4H‐SiC trench metal‐oxide semiconductor field‐effect transistor test structures by scanning near‐field optical Raman microscope
We prepared two types of trench‐test metal‐oxide semiconductor field‐effect transistor (MOSFET) structures on m‐ and a‐faces in 4H silicon carbide (4H‐SiC) and investigated the anisotropic stress distribution of small trenches with a depth of 1 μm using a scanning near‐field optical Raman microscope (SNOM) that we developed. The stress distributions of σ11 (a‐axis) under the bottom of the trench for m‐face were approximately 100 MPa larger than those for a‐face, and the stress distributions of σ33 (c‐axis) under the bottom of the trench for m‐face were almost the same as those for a‐face. The experimental result agrees well with that calculated by the finite element method (FEM). These results indicate that the anisotropic stress distributions of σ11 components around the apex of the trenches of 4H‐SiC trench‐test MOSFET occur in m‐ and a‐faces. Thus, it is possible that the differences in mobilities for m‐ and a‐faces might be caused by the anisotropic stresses.
- 25 May 2024
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 55 (9) , 982-988
Anisotropic stress observation of 4H‐SiC trench metal‐oxide semiconductor field‐effect transistor test structures by scanning near‐field optical Raman microscope
We prepared two types of trench‐test metal‐oxide semiconductor field‐effect transistor (MOSFET) structures on m‐ and a‐faces in 4H silicon carbide (4H‐SiC) and investigated the anisotropic stress distribution of small trenches with a depth of 1 μm using a scanning near‐field optical Raman microscope (SNOM) that we developed. The stress distributions of σ11 (a‐axis) under the bottom of the trench for m‐face were approximately 100 MPa larger than those for a‐face, and the stress distributions of σ33 (c‐axis) under the bottom of the trench for m‐face were almost the same as those for a‐face. The experimental result agrees well with that calculated by the finite element method (FEM). These results indicate that the anisotropic stress distributions of σ11 components around the apex of the trenches of 4H‐SiC trench‐test MOSFET occur in m‐ and a‐faces. Thus, it is possible that the differences in mobilities for m‐ and a‐faces might be caused by the anisotropic stresses.
- 24 March 2023
- Published by Springer Nature
- p. 143-155
STEM-CL
- 24 March 2023
- Published by Springer Nature
- p. 1-2
Introduction
- 24 March 2023
- Published by Springer Nature
- p. 157-204
Topics