DTDamber Thapa

Damber Thapa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Damber Thapa has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantitative photothermal analysis and multispectral imaging of dental structures: insights into optical and thermal properties of carious and healthy teeth

    by Elnaz Baradaran Shokouhi, Damber Thapa, Robert Welch, Koneswaran Sivagurunathan, Andreas Mandelis

    SignificanceIn the analysis of two-layered turbid dental tissues, the outer finite-thickness layer is modeled by an optical transport coefficient distinct from its underlying semi-infinite substrate layer. The optical and thermophysical parameters of healthy and carious teeth across the various wavelengths were measured leading to the determination of the degree of reliability of each of the fitted parameters, with most reliable being thermal diffusivity and conductivity, enamel thickness, and optical transport coefficient of the enamel layer. Quantitative pixel-by-pixel images of the key reliable optical and thermophysical parameters were constructed.AimWe introduced a theoretical model of pulsed photothermal radiometry based on conduction-radiation theory and applied to quantitative photothermal detection and imaging of biomaterials. The theoretical model integrates a combination of inverse Fourier transformation techniques, avoiding the conventional cumbersome analytical Laplace transform method.ApproachTwo dental samples were selected for analysis: the first sample featured controlled, artificially induced early caries on a healthy tooth surface, while the second sample exhibited natural defects along with an internal filling. Using an Nd:YAG laser and specific optical parametric oscillator (OPO) wavelengths (675, 700, 750, and 808 nm), photothermal transient signals were captured from different points on these teeth and analyzed as a function of OPO wavelength. Measurements were also performed with an 808-nm laser diode for comparison with the same OPO wavelength excitation, particularly for the second sample with natural defects.ResultsThe findings demonstrated that the photothermal transient signals exhibit a fast-decaying pattern at shorter wavelengths due to their higher scattering nature, while increased scattering and absorption in the carious regions masked conductive and radiative contributions from the underlayer. These observations were cross-validated using micro-computed tomography, which also enabled the examination of signal patterns at different tooth locations.ConclusionsThe results of our study showed the impact of optical and thermal characteristics of two-layered turbid dental tissues via an inverse Fourier technique, as well as the interactions between these layers, on the patterns observed in depth profiles.


  • Open Access

    Three-dimensional thermophotonic super-resolution imaging by spatiotemporal diffusion reversal method

    by Damber Thapa, Pantea Tavakolian, George Zhou, Alan Zhang, Asser Abdelgawad, Elnaz Baradaran Shokouhi, Koneswaran Sivagurunathan, Andreas Mandelis

    Spatial super-resolution in thermophotonic imaging was achieved using a combination of spatial second-derivative forming, spatial gradient adaptive filtering, and Richardson-Lucy deconvolution in conjunction with the construction of an experimental point spread function. When implemented through enhanced truncation-correlation photothermal coherence tomography (eTC-PCT), it was possible to restore blurred infrared thermophotonic images to their prediffusion optical resolution state. This modality was tested in various biological applications and proved to be capable of imaging fine axial cracks in human teeth, well-patterned anatomical subsurface structures of a mouse brain, and neovascularization in a mouse thigh due to the rapid proliferation of cancer cells. This modality was found to be immune to optical scattering and could reveal the true spatial extent of biological features at subsurface depths that conventional thermal imaging cannot reach because of limitations imposed by the physics of spreading diffusion.


  • Handheld Point-of-Care Device for the Quantification of Anti-SARS-CoV-2 Antibodies

    by Damber Thapa, Nakisa Samadi, Nima Tabatabaei

    Antibodies that are produced following infection due to the SARS-CoV-2 virus or vaccination are critical for monitoring the immune response of an individual or the impact of the vaccine over time. As vaccines become available, there is a need for rapid, accurate, and low-cost point-of-care tools for monitoring the effectiveness of the vaccines over time at the population level. Here, we report the efficiency of a handheld point-of-care thermo-photonic device for quantifying anti-SARS-CoV-2 antibodies in humanized control positive solution. Results showed that the imager in conjunction with rapid diagnostic tests (RDT) can detect and quantify antibody levels within clinically relevant range and with a limit of detection of 0.1 µg/ml.

  • Comparison of Long-Wave and Mid-Wave Infrared Imaging Modalities for Photothermal Coherence Tomography of Human Teeth

    by Damber Thapa, Robert Welch, Rimple Poonia Dabas, Mohammahhossein Salimi, Pantea Tavakolian, Koneswaran Sivagurunathan, Kimberly Ngai, Bo Huang, Yoav Finer, Stephen Abrams, et al.

    The ability to detect dental caries at early stages lies at the heart of minimal intervention dentistry, enabling the curing or arresting of carious lesions before they advance to the cavity stage. Enhanced truncated-correlation photothermal coherence tomography (eTC-PCT) using mid-wave infrared (MWIR) cameras has recently been shown to offer tomographic visualization of early caries. The tomographic slicing ability of such systems, however, is believed to be limited by direct radiative thermal emission through the translucent dental enamel in the 3-5 µm MWIR spectral range. Such radiative emissions can dominate the delayed conductive thermal contributions needed for tomographic reconstruction of internal dental defects. It has been hypothesized that long-wave infrared (LWIR) eTC-PCT systems may offer better tomographic performance by taking advantage of the intrinsic attenuation of direct radiative emission by dental enamel in the LWIR spectral range, enabling more effective delayed conductive thermal contributions from subsurface caries. More than an order of magnitude lower cost of the system is another key attribute of LWIR eTC-PCT which can open the door for downstream translation of the technology to clinics. In this report, we offer a systematic comparison of the performance/effectiveness of caries detection with LWIR and MWIR eTC-PCT systems for detecting natural caries, bacterial caries, and artificially demineralized enamel surfaces. Our results suggest that the low-cost LWIR based eTC-PCT system provides 3D visualization and 2D slice-by-slice images of early caries and internal micro-cracks similar to those obtained from the more expensive MWIR-based eTC-PCT system, albeit with ∼1.3dB lower signal-to-noise ratio.


  • Handheld Thermo-Photonic Device for Rapid, Low-Cost, and On-Site Detection and Quantification of Anti-SARS-CoV-2 Antibody

    by Damber Thapa, Nakisa Samadi, Nima Tabatabaei

    With the emergence of vaccines and antibody therapeutics, rapid and scalable platforms are needed to quantify the antibody response of individuals. Lateral flow immunoassay (LFA) based test strips provide a rapid, low-cost, and point-of-care approach to antibody testing against the SARS-CoV-2 virus. These convenient and scalable tests, however, are qualitative in nature and cannot quantify the immune response of the infected and/or vaccinated individuals. This study reports on the development of a rapid, low cost and portable thermo-photonic device that enables sensitive detection and quantification of antibody levels using commercially available COVID-19 Antibody LFAs. Unlike conventional LFA readers, the developed technology is based on sensing the infrared thermal radiation of tag gold nanoparticles following laser excitation (aka photothermal response). Our proof-of-concept results with humanized monoclonal anti-SARS-CoV-2 Spike receptor-binding domain (RBD) IgG demonstrate that the thermo-photonic technology can detect and quantify antibody concentrations within the clinically relevant range and with a limit of detection of $0.1~\mu \text{g}$ /ml. The reader in conjunction with antibody LFAs offers a low-cost, portable, and scalable solution for assessment of the degree of immunity in populations, quality control of convalescent plasma donations for antibody therapeutics, and monitoring the immune response of infected individuals and vaccine recipients.


  • Open Access

    In vivo super-resolution retinal imaging through virtually structured detection

    by Changgeng Liu, Yanan Zhi, Benquan Wang, Damber Thapa, Yanjun Chen, Minhaj Alam, Yiming Lu, Xincheng Yao

    High resolution is important for sensitive detection of subtle distortions of retinal morphology at an early stage of eye diseases. We demonstrate virtually structured detection (VSD) as a feasible method to achieve in vivo super-resolution ophthalmoscopy. A line-scanning strategy was employed to achieve a super-resolution imaging speed up to 127  frames/s with a frame size of 512×512  pixels. The proof-of-concept experiment was performed on anesthetized frogs. VSD-based super-resolution images reveal individual photoreceptors and nerve fiber bundles unambiguously. Both image contrast and signal-to-noise ratio are significantly improved due to the VSD implementation.


  • Stimulus-evoked outer segment changes in rod photoreceptors

    by Xiaohui Zhao, Damber Thapa, Benquan Wang, Yiming Lu, Shaoyan Gai, Xincheng Yao

    Rod-dominated transient retinal phototropism (TRP) has been recently observed in freshly isolated mouse and frog retinas. Comparative confocal microscopy and optical coherence tomography revealed that the TRP was predominantly elicited from the rod outer segment (OS). However, the biophysical mechanism of rod OS dynamics is still unknown. Mouse and frog retinal slices, which displayed a cross-section of retinal photoreceptors and other functional layers, were used to test the effect of light stimulation on rod OSs. Time-lapse microscopy revealed stimulus-evoked conformational changes of rod OSs. In the center of the stimulated region, the length of the rod OS shrunk, while in the peripheral region, the rod OS swung toward the center region. Our experimental observation and theoretical analysis suggest that the TRP may reflect unbalanced rod disc-shape changes due to localized visible light stimulation.


  • Compressive Sensing

    by Vasudevan Lakshminarayanan, Damber Thapa, Kaamran Raahemifar, Hossein Rabbani

    Compressive sensing (CS) is an emerging sampling theory, which reproduces signals from a much smaller set of samples than that required by the Nyquist‐Shannon criterion. Since its introduction in the mid‐2000s it has attracted considerable research interest and a number of CS‐based architectures have been proposed, built, and examined in the research labs. This article outlines the main theoretical concepts surrounding CS and also discusses some of its applications in the field of optics and image science.