Yong Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yong Yang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Meirong Zhao
Tianjin Univ, State Key Lab Precis Measuring Technol & Instrumen, Tianjin 300072, Peoples R China
3 shared publications- Yelong Zheng
Tianjin University
3 shared publications - Le Song
Tianjin University
2 shared publications Yelong Zheng
2 shared publicationsDantong Li
Tianjin University
1 shared publicationDexin Yu
1 shared publication
Latest Publications
- Open Access
- 30 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (5) , eaeb7242
One-stop strabismus digital diagnosis via AI-integrated skin-like and wearable “Eyelectronics”
Strabismus, affecting ~4% of children, impairs vision and psychosocial health. However, clinical diagnosis requires multiple instruments and stepwise examinations of ocular alignment, extraocular muscle function, and deviation angle. It is limited by low diagnostic objectivity, poor pediatric compliance, and high cost. Here, we propose a strategy for one-stop strabismus digital diagnosis via artificial intelligence (AI)–integrated, skin-like, and wearable “Eyelectronics.” The ultralightweight, imperceptible eye-wearable system features an ultrathin (~60 micrometers in thickness), breathable, and multidirectional (0°/45°/90°) strain-sensing array conformally adapted to the sensitive eyelid. It enables wireless, mild-restricted measurement of eyelid deformation during eye movements. Through biomechanical modeling validated by ocular magnetic resonance imaging simulations, we establish a prior correlation between eyelid deformation and eye movements. The Eyelectronics, powered by our physiology knowledge-driven end-to-end AI algorithm, achieves simultaneous measurement of strabismus angle and identification of paretic muscle. It delivers a 96.6% four-direction classification accuracy and a 1.2° measurement accuracy in ocular motility examinations. Clinical benchmarking against the clinical standard (Hess screen test) confirmed diagnostic agreement (intraclass correlation = 0.978). This system bridges quantitative biomechanical sensing with digital diagnosis, promoting a paradigm for future strabismus treatment.
- 30 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (5) , eaeb7242
Open AccessOne-stop strabismus digital diagnosis via AI-integrated skin-like and wearable “Eyelectronics”
Strabismus, affecting ~4% of children, impairs vision and psychosocial health. However, clinical diagnosis requires multiple instruments and stepwise examinations of ocular alignment, extraocular muscle function, and deviation angle. It is limited by low diagnostic objectivity, poor pediatric compliance, and high cost. Here, we propose a strategy for one-stop strabismus digital diagnosis via artificial intelligence (AI)–integrated, skin-like, and wearable “Eyelectronics.” The ultralightweight, imperceptible eye-wearable system features an ultrathin (~60 micrometers in thickness), breathable, and multidirectional (0°/45°/90°) strain-sensing array conformally adapted to the sensitive eyelid. It enables wireless, mild-restricted measurement of eyelid deformation during eye movements. Through biomechanical modeling validated by ocular magnetic resonance imaging simulations, we establish a prior correlation between eyelid deformation and eye movements. The Eyelectronics, powered by our physiology knowledge-driven end-to-end AI algorithm, achieves simultaneous measurement of strabismus angle and identification of paretic muscle. It delivers a 96.6% four-direction classification accuracy and a 1.2° measurement accuracy in ocular motility examinations. Clinical benchmarking against the clinical standard (Hess screen test) confirmed diagnostic agreement (intraclass correlation = 0.978). This system bridges quantitative biomechanical sensing with digital diagnosis, promoting a paradigm for future strabismus treatment.
- 25 October 2023
- Published by Elsevier in Optics & Laser Technology
- Vol. 170
A reflective multimode fiber vector bending sensor based on specklegram
- 25 October 2023
- Published by Elsevier in Optics & Laser Technology
- Vol. 170
A reflective multimode fiber vector bending sensor based on specklegram
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (16) , 17958-17967
A Tactile Sensor With Slippage Prediction by Unequal-Height Dome Array
Tactile sensors are essential to enable manipulators to perform complex tasks like human hands. Slippage prediction helps manipulators avoid dropping grasped objects. Here, we present a vision-based tactile sensor with an unequal height dome array to predict slippage without the slippage occurring. The sum of each shading area and the sum of each area center displacements in the image are linear to the applied normal force and tangential force respectively. The resolutions of the normal force and the tangential force can both reach 10 mN with maximum relative uncertainties of approximately 5.47% and 4.78%. Under a certain normal force, the small dome will be applied a smaller tangential force due to a more minor normal force component, causing them to slip earlier. The sliding time difference between the large and small domes can be utilized to realize slippage prediction subtly. Hence, this sensor is expected to help robots ensure safe contact and move objects safely in case of a possible collision.
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (16) , 17958-17967
A Tactile Sensor With Slippage Prediction by Unequal-Height Dome Array
Tactile sensors are essential to enable manipulators to perform complex tasks like human hands. Slippage prediction helps manipulators avoid dropping grasped objects. Here, we present a vision-based tactile sensor with an unequal height dome array to predict slippage without the slippage occurring. The sum of each shading area and the sum of each area center displacements in the image are linear to the applied normal force and tangential force respectively. The resolutions of the normal force and the tangential force can both reach 10 mN with maximum relative uncertainties of approximately 5.47% and 4.78%. Under a certain normal force, the small dome will be applied a smaller tangential force due to a more minor normal force component, causing them to slip earlier. The sliding time difference between the large and small domes can be utilized to realize slippage prediction subtly. Hence, this sensor is expected to help robots ensure safe contact and move objects safely in case of a possible collision.
- 22 November 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (25) , 44518-44532
Method for parallelism measurement of geometrical waveguides based on the combination of an autocollimator and a testing telescope
Augmented reality (AR) is desperately needed in the Metaverse. The geometrical waveguide receives increased attention in AR technology as achieving high resolution, full-color display, etc. However, the stray light and ghost image problems resulting from the parallelism errors severely deteriorate the imaging quality. According to the light propagation of the waveguide, a measuring system based on the combination of the autocollimator and the testing telescope (CAT) method was proposed to measure the parallelism errors of the partially reflective mirror array (PRMA). The results indicated that this method could measure the parallelism errors precisely with the maximum repeatability of 0.63 ′ ′ . The method could decouple the coupling of the parallelism errors of the PRMA and the substrate surfaces to imaging quality effectively. The precise parallelism measuring is expected to contribute to mass production and low cost by promoting the waveguide design and fabrication.
- 22 November 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (25) , 44518-44532
Method for parallelism measurement of geometrical waveguides based on the combination of an autocollimator and a testing telescope
Augmented reality (AR) is desperately needed in the Metaverse. The geometrical waveguide receives increased attention in AR technology as achieving high resolution, full-color display, etc. However, the stray light and ghost image problems resulting from the parallelism errors severely deteriorate the imaging quality. According to the light propagation of the waveguide, a measuring system based on the combination of the autocollimator and the testing telescope (CAT) method was proposed to measure the parallelism errors of the partially reflective mirror array (PRMA). The results indicated that this method could measure the parallelism errors precisely with the maximum repeatability of 0.63 ′ ′ . The method could decouple the coupling of the parallelism errors of the PRMA and the substrate surfaces to imaging quality effectively. The precise parallelism measuring is expected to contribute to mass production and low cost by promoting the waveguide design and fabrication.
- 30 August 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (11) , 114010
Micro-force sensing techniques and traceable reference forces: a review
Micro-force measurement with high resolution, accuracy, and reliability is of interest in a broad range of applications including gravitational-wave detection, intelligent healthcare, bionic robotics, and micromanipulation. Herein, the researchand development in recent years of micro-force sensors based on various principles is reviewed thoroughly, presenting their characteristics and applications, as well as summarizing their advantages and limitations. The most indispensable component of force sensors, elastic sensitive elements, is underlined. Next, four kinds of not widely used but promising sensors are also introduced briefly. Finally, the traceable reference forces are analyzed, concluding with a future perspective into the corresponding challenges and opportunities of micro-force sensors for future research. This review aims at providing references for developing micro-force sensors and improving their performance.
- 30 August 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (11) , 114010
Micro-force sensing techniques and traceable reference forces: a review
Micro-force measurement with high resolution, accuracy, and reliability is of interest in a broad range of applications including gravitational-wave detection, intelligent healthcare, bionic robotics, and micromanipulation. Herein, the researchand development in recent years of micro-force sensors based on various principles is reviewed thoroughly, presenting their characteristics and applications, as well as summarizing their advantages and limitations. The most indispensable component of force sensors, elastic sensitive elements, is underlined. Next, four kinds of not widely used but promising sensors are also introduced briefly. Finally, the traceable reference forces are analyzed, concluding with a future perspective into the corresponding challenges and opportunities of micro-force sensors for future research. This review aims at providing references for developing micro-force sensors and improving their performance.
- 26 April 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (22) , G9-G14
Development of a nanoscale displacement sensor based on the shadow method
A novel, to the best of our knowledge, bionic coaxial micro-displacement sensor based on the shadow method is developed and experimentally demonstrated inspired by the water strider walking on the water. The water is used as the sensitive element to measure the micro- displacement. A meniscus is formed by the superhydrophobic circular plate subjected to a coaxial displacement excitation. Then a shadow is formed because of the refraction when the parallel light illuminates the meniscus. A maximum coaxial displacement sensitivity of 62 nm/pixel over the displacement range of 50 µm is achieved experimentally. The linearity error in the measurement range was 1.58%. Therefore, it is expected that this displacement sensor can be used in many important ultraprecision measurement fields because of the advantages of the easy structure and high resolution.
- 26 April 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (22) , G9-G14
Development of a nanoscale displacement sensor based on the shadow method
A novel, to the best of our knowledge, bionic coaxial micro-displacement sensor based on the shadow method is developed and experimentally demonstrated inspired by the water strider walking on the water. The water is used as the sensitive element to measure the micro- displacement. A meniscus is formed by the superhydrophobic circular plate subjected to a coaxial displacement excitation. Then a shadow is formed because of the refraction when the parallel light illuminates the meniscus. A maximum coaxial displacement sensitivity of 62 nm/pixel over the displacement range of 50 µm is achieved experimentally. The linearity error in the measurement range was 1.58%. Therefore, it is expected that this displacement sensor can be used in many important ultraprecision measurement fields because of the advantages of the easy structure and high resolution.
- 6 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Study on Energy Stress of DC Circuit Breakers after Pole-to-pole Fault of VSC-HVDC Grid
DC circuit breaker (DCB) is the core equipment of high voltage DC (HVDC) grid based on voltage source converter (VSC). However DCB absorbs huge energy by metal oxide arrester (MOA) in it when breaking short circuit current. The overlarge energy will easily result in damage of MOA and badly limited the application of DCB. To solve this problem, this paper studies the mechanism of MOA of DCB absorbing energy after the most severe fault, the pole-to-pole fault, of VSC-HVDC grid. The theoretical calculation method of MOA energy stress of DCB is presented. A new protection strategy is provided to suppress MOA energy stress without adding any extra equipment. The actual 4-side VSC-HVDC grid is modelled and simulated based on PSCAD/EMTDC to verify the theoretical analysis results. The calculation results show that compared with the original strategy, the MOA energy stress of DCB can be reduced from 254.5MJ to 145.6MJ by using the new strategy.
- 6 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Study on Energy Stress of DC Circuit Breakers after Pole-to-pole Fault of VSC-HVDC Grid
DC circuit breaker (DCB) is the core equipment of high voltage DC (HVDC) grid based on voltage source converter (VSC). However DCB absorbs huge energy by metal oxide arrester (MOA) in it when breaking short circuit current. The overlarge energy will easily result in damage of MOA and badly limited the application of DCB. To solve this problem, this paper studies the mechanism of MOA of DCB absorbing energy after the most severe fault, the pole-to-pole fault, of VSC-HVDC grid. The theoretical calculation method of MOA energy stress of DCB is presented. A new protection strategy is provided to suppress MOA energy stress without adding any extra equipment. The actual 4-side VSC-HVDC grid is modelled and simulated based on PSCAD/EMTDC to verify the theoretical analysis results. The calculation results show that compared with the original strategy, the MOA energy stress of DCB can be reduced from 254.5MJ to 145.6MJ by using the new strategy.