JCJavier Omar Castillo-Miranda

Javier Omar Castillo-Miranda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Javier Omar Castillo-Miranda has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mapeo del Índice de Aire y Salud por contaminación atmosférica de partículas finas PM2.5 en la Zona Metropolitana del Valle de Puebla

    by Javier O. Castillo-Miranda, José A. García-Reynoso, Gabriela Pérez-Osorio, José C. Mendoza-Hernández

    Se construyen mapas híbridos de índices de Aire y Salud (IAS) de partículas en suspensión menores a 2.5 micrómetros (PM2.5), de mediciones de la Red Estatal de Monitoreo Automática (REMA) y estimaciones basadas en datos satelitales del Servicio de Monitoreo Atmosférico de Copernicus (CAMS). Se estima el IAS para PM2.5 en zonas donde la REMA no tienen alcance empleando la información de CAMS, para describir la contaminación atmosférica en la zona de estudio. Se emplea el sistema de información geográfica ArcGis para representar espacial y temporalmente los mapas de IAS promedio mensual del año 2021. Se observa que durante la temporada fría-seca se representa el mayor riesgo a la salud, donde la zona suroeste en el mes diciembre implican un nivel de riesgo muy alto. Los IAS en las estaciones CCA, DICA y UTP estimados mediante CAMS y utilizados en la modelación con ArcGIS contribuyen en la predicción de eventos de riesgo moderado de IAS de PM2.5. Esto ocurre en las temporadas cálida-seca y fría-seca en una escala regional durante el año 2021.

  • Open Access

    Enhancing Air Quality Forecasting in the Metropolitan Zone of the Valley of Puebla: A Comparative Analysis of CAMS and REMA Data

    by Javier Omar Castillo-Miranda, José Carlos Mendoza-Hernández, José Agustín García-Reynoso, Gabriela Pérez-Osorio

    Air quality in the Metropolitan Zone of the Valley of Puebla has shown in previous years that suspended particles less than 10 micrometers (PM10) and less than 2.5 micrometers (PM2.5) present a health risk. The automatic air quality monitoring system in Puebla measures PM10 and PM2.5 at five stations in the Puebla and Coronango municipalities. These measurements allow for the determination of the Air and Health Index according to the NOM-172-SEMARNAT-2019 standard for these pollutants. The advancement of satellite monitoring techniques represents an opportunity for air quality management where terrestrial measurements are scarce. However, to obtain reliable data, it is necessary to validate the satellite data with ground measurements from georeferenced monitoring stations. The operational implementation forecast of the Copernicus Atmospheric Monitoring Service (CAMS) allows for conducting out atmospheric pollution exploration processes. An analysis of this forecast data determined that the Persistence forecast is better than the CAMS forecast overall for both PM10 and PM2.5. However, the CAMS forecast can be employment for a preliminary evaluation in the prediction of PM2.5 due to the success in the comparison criteria of the dichotomous statistics ACCURACY, POD, FAR, POFD, SR, TS, ETS, HSS and ORSS.

  • Mapping of the cost of atmospheric corrosion of zinc and galvanised steel due to the effect of atmospheric pollution in the Mexico City Metropolitan area

    by J. O. Castillo-Miranda, F. J. Rodríguez-Gómez

    The deterioration of materials due to the effect of atmospheric pollution generates a cost to society because the maintenance and replacement of degraded materials. Galvanised steel is used in electrical industry to build electrical transmission towers (ETT). The objective of the study was to estimate the annual maintenance cost of galvanised steel used in the construction of ETT. The maintenance cost for galvanised steel was estimated considering the cost of the material surface area and the difference between the maintenance interval of clean and contaminated areas. Maps of intervals and maintenance costs were obtained for galvanised steel (85 and 100 µm), which are the thicknesses regulated in Mexico for ETT. In addition, an ArcGis geographic information system was used for a spatial representation of data from the anthropogenic environment. The mapping of areas at risk of corrosion shows that in the northwest zone, ETT presents the highest maintenance costs for the year 2019. For galvanised steel thicknesses of 85 and 100 µm, there are annual costs of, respectively, 8.68 and 10.16 USD/m2.


  • Open Access

    Estimation and mapping of the contribution of nitric acid to atmospheric corrosion of zinc

    by J. O. Castillo-Miranda, F. J. Rodríguez-Gómez, J. Genescá-Llongueras, L. G. Ruiz-Suárez, J. A. García-Reynoso