Daniel Braga
Research Subjects
Daniel Braga has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Adam Zybulewski
Department of Vascular and Interventional Radiology, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140; Department of Vascular and Endovascular Surgery, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140
1 shared publication- Alexander Ushinsky
Mallinckrodt Institute of Radiology, Washington University Saint Louis, St. Louis, MO 63110, USA
1 shared publication Amir Ata Rahnemai-Azar
Department of Interventional Radiology, Mallinckrodt Institute of Radiology, St. Louis, Missouri
1 shared publicationAndrew Camardo
Centerline Biomedical, Inc., Cleveland, OH, USA
1 shared publicationBrandon Olivieri
Department of Vascular and Interventional Radiology, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140; Department of Vascular and Endovascular Surgery, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140
1 shared publication- Carlos Javier Guevara
Department of Interventional Radiology, Mallinckrodt Institute of Radiology, St. Louis, Missouri
1 shared publication
Latest Publications
- Open Access
- 10 September 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (1) , 107834
Modeling Clinical Relevance and Risk in Yttrium-90 Radioembolization of the Liver: Lung Shunt Fraction Variability According to Imaging Modality, Cancer Type, and Tumor Size
- 10 September 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (1) , 107834
Open AccessModeling Clinical Relevance and Risk in Yttrium-90 Radioembolization of the Liver: Lung Shunt Fraction Variability According to Imaging Modality, Cancer Type, and Tumor Size
- Open Access
- 10 December 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (4) , 635-640
A Laser Atherectomy-Thrombectomy System for Primary Management of Acute Limb Ischemia
- 10 December 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (4) , 635-640
Open AccessA Laser Atherectomy-Thrombectomy System for Primary Management of Acute Limb Ischemia
- 14 December 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
Nonfluoroscopic 3D Image Guidance System Reduces Navigation Times Through Five 3D-Printed Iliofemoral Vascular Phantoms
Purpose: To assess the potential adjunctive role of a 3D electromagnetic (EM) navigational system for use in above-knee vessels afflicted with peripheral artery disease (PAD). Peripheral artery disease can be challenging to operators encountering significant vessel tortuosity, calcium, and stenoses, which may require prolonged procedure times and excessive use of nephrotoxic iodinated contrast when performed with conventional fluoroscopy. Materials and Methods: Following appropriate ethical oversight, five 3D-printed bench phantoms modeling tortuous calcified PAD were created based on source CTA (computed tomography angiography) data sets from real patients. Investigational software was developed based on a commercially available aortic EM navigation platform (Intraoperative Positioning System [IOPS]; Centerline Biomedical, Inc., Cleveland, Ohio), with patient-specific structural maps of vessel lumens and calcification. Using a sensorized prototype 6 French (Fr) catheter and 0.035” guidewire, 15 interventionalists traversed each phantom using the EM platform as well as 2D simulated fluoroscopy-like image guidance and the times were recorded. Participants completed a 10-item standard system usability scale (SUS) questionnaire (score 1–5, 5= strongly agree) evaluating system usability and user satisfaction. Navigation times and SUS scores were compared with a 1-tailed statistical t test. Results: Participants demonstrated a statistically significant reduction in navigation times using EM guidance, performing 0.7 minutes (42 seconds) faster on average ( P < .001), corresponding to a 25% average relative reduction. Participants reported sufficiently high levels of usability satisfaction, with a mean SUS score of 4.29 ( P < .001), exceeding the acceptance criterion (score ≥3.5). Conclusion: This preclinical phantom study highlights the future potential of Centerline Biomedical’s EM navigation technology as a possible adjunct to fluoroscopy for highly precise visualization and navigation of PAD-afflicted vasculature. Clinical Impact: This preclinical proof-of-concept study highlights the feasibility of EM navigation not only for branch vessel cannulation, but also for inline navigation of peripheral vessels afflicted with calcified plaques via benchtop iliofemoral phantom simulations. The navigation platform studied addresses the need for improvements in EM technology through modelling algorithms that facilitate 3D visualization of calcified plaque in any projection in real time, in addition to sensorization of both catheter and guidewire in a compact 6Fr system.
- 14 December 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
Nonfluoroscopic 3D Image Guidance System Reduces Navigation Times Through Five 3D-Printed Iliofemoral Vascular Phantoms
Purpose: To assess the potential adjunctive role of a 3D electromagnetic (EM) navigational system for use in above-knee vessels afflicted with peripheral artery disease (PAD). Peripheral artery disease can be challenging to operators encountering significant vessel tortuosity, calcium, and stenoses, which may require prolonged procedure times and excessive use of nephrotoxic iodinated contrast when performed with conventional fluoroscopy. Materials and Methods: Following appropriate ethical oversight, five 3D-printed bench phantoms modeling tortuous calcified PAD were created based on source CTA (computed tomography angiography) data sets from real patients. Investigational software was developed based on a commercially available aortic EM navigation platform (Intraoperative Positioning System [IOPS]; Centerline Biomedical, Inc., Cleveland, Ohio), with patient-specific structural maps of vessel lumens and calcification. Using a sensorized prototype 6 French (Fr) catheter and 0.035” guidewire, 15 interventionalists traversed each phantom using the EM platform as well as 2D simulated fluoroscopy-like image guidance and the times were recorded. Participants completed a 10-item standard system usability scale (SUS) questionnaire (score 1–5, 5= strongly agree) evaluating system usability and user satisfaction. Navigation times and SUS scores were compared with a 1-tailed statistical t test. Results: Participants demonstrated a statistically significant reduction in navigation times using EM guidance, performing 0.7 minutes (42 seconds) faster on average ( P < .001), corresponding to a 25% average relative reduction. Participants reported sufficiently high levels of usability satisfaction, with a mean SUS score of 4.29 ( P < .001), exceeding the acceptance criterion (score ≥3.5). Conclusion: This preclinical phantom study highlights the future potential of Centerline Biomedical’s EM navigation technology as a possible adjunct to fluoroscopy for highly precise visualization and navigation of PAD-afflicted vasculature. Clinical Impact: This preclinical proof-of-concept study highlights the feasibility of EM navigation not only for branch vessel cannulation, but also for inline navigation of peripheral vessels afflicted with calcified plaques via benchtop iliofemoral phantom simulations. The navigation platform studied addresses the need for improvements in EM technology through modelling algorithms that facilitate 3D visualization of calcified plaque in any projection in real time, in addition to sensorization of both catheter and guidewire in a compact 6Fr system.
- 13 May 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 33 (8) , 1010-1012
Transvenous Exclusion of a Type II Endoleak Complicated by Ilio-Iliac Arteriovenous Fistula
- 13 May 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 33 (8) , 1010-1012
Transvenous Exclusion of a Type II Endoleak Complicated by Ilio-Iliac Arteriovenous Fistula