Zhengming Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhengming Jiang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Bin Zhang
Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
1 shared publicationChao Chang
Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
1 shared publicationChengqian Yin
Interventional Center of Valvular Heart Disease, Beijing Anzhen Hospital, National Clinical Research Centre for Cardiovascular Diseases, Capital Medical University, Beijing, China
1 shared publicationFei Yuan
Interventional Center of Valvular Heart Disease, Beijing Anzhen Hospital, National Clinical Research Centre for Cardiovascular Diseases, Capital Medical University, Beijing, China
1 shared publication- Guangyuan Song
Interventional Center of Valvular Heart Disease, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
1 shared publication Guizhi Liu
Department of Cardiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
1 shared publication
Latest Publications
- Open Access
- 25 January 2023
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 978394
Feasibility study of temporary permanent pacemaker in patients with conduction block after TAVR
Background: Limited data exist on the use of temporary permanent pacemaker (TPPM) to reduce unnecessary PPM in patients with high-degree atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR).Objectives: This study aims to determine the feasibility of TPPM in patients with HAVB after TAVR to provide prolonged pacing as a bridge.Materials and methods: One hundred and eleven consecutive patients undergoing TAVR were screened from August 2021 to June 2022. Patients with HAVB eligible for PPM were included. TPPM were used in these patients instead of conventional temporary pacing or early PPM. Patients were followed up for 1 month. Holter and pacemaker interrogation were used to determine whether to implant PPM.Results: Twenty one patients met the inclusion criteria for TPPM, of which 14 patients were third-degree AVB, 1 patient was second-degree AVB, 6 patients were first degree AVB with PR interval > 240 ms and LBBB with QRS duration > 150 ms. TPPM were placed on the 21 patients for 35 ± 7 days. Among 15 patients with HAVB, 26.7% of them (n = 4) recovered to sinus rhythm; 46.7% (n = 7) recovered to sinus rhythm with bundle branch block. The remains of 26.7% patients (n = 4) still had third-degree AVB and received PPM. For patients with first-degree AVB and LBBB, PR interval shortened to < 200 ms in all 6 patients and LBBB recovered in 2 patients. TPPM were successfully removed from all patients and no procedure-related adverse events occurred.Conclusion: TPPM is reliable and safe in the small sample of patients with conduction block after TAVR to provide certain buffer time to distinguish whether a PPM is necessary. Future studies with larger sample are needed for further validation of the current results.
- 25 January 2023
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 978394
Open AccessFeasibility study of temporary permanent pacemaker in patients with conduction block after TAVR
Background: Limited data exist on the use of temporary permanent pacemaker (TPPM) to reduce unnecessary PPM in patients with high-degree atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR).Objectives: This study aims to determine the feasibility of TPPM in patients with HAVB after TAVR to provide prolonged pacing as a bridge.Materials and methods: One hundred and eleven consecutive patients undergoing TAVR were screened from August 2021 to June 2022. Patients with HAVB eligible for PPM were included. TPPM were used in these patients instead of conventional temporary pacing or early PPM. Patients were followed up for 1 month. Holter and pacemaker interrogation were used to determine whether to implant PPM.Results: Twenty one patients met the inclusion criteria for TPPM, of which 14 patients were third-degree AVB, 1 patient was second-degree AVB, 6 patients were first degree AVB with PR interval > 240 ms and LBBB with QRS duration > 150 ms. TPPM were placed on the 21 patients for 35 ± 7 days. Among 15 patients with HAVB, 26.7% of them (n = 4) recovered to sinus rhythm; 46.7% (n = 7) recovered to sinus rhythm with bundle branch block. The remains of 26.7% patients (n = 4) still had third-degree AVB and received PPM. For patients with first-degree AVB and LBBB, PR interval shortened to < 200 ms in all 6 patients and LBBB recovered in 2 patients. TPPM were successfully removed from all patients and no procedure-related adverse events occurred.Conclusion: TPPM is reliable and safe in the small sample of patients with conduction block after TAVR to provide certain buffer time to distinguish whether a PPM is necessary. Future studies with larger sample are needed for further validation of the current results.
- 14 May 2022
- Published by Elsevier in Clinical Therapeutics
- Vol. 44 (6) , 901-912
Early Initiation of Evolocumab Treatment in Chinese Patients With Acute Coronary Syndrome Undergoing Percutaneous Coronary Intervention
- 14 May 2022
- Published by Elsevier in Clinical Therapeutics
- Vol. 44 (6) , 901-912
Early Initiation of Evolocumab Treatment in Chinese Patients With Acute Coronary Syndrome Undergoing Percutaneous Coronary Intervention