ZZZhi Zheng

Zhi Zheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhi Zheng has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mobile MIMO Radar Imaging via Synergistic Deep Learning and Wave Physics Modeling

    by Siyuan Zhao, Lue Wen, Kunpeng Qiu, Zhi Zheng, Tiantian Yin, Xudong Chen, Yongxin Guo

  • Enhanced Radar Fall Detection via Compressed Sensing and Deep Learning-Assisted Point Cloud Generation

    by Zhi Zheng, Siyuan Zhao, Bo Wang, Zhiying Zhou, Xudong Chen, Yongxin Guo

    Existing fall detection based on radar point cloud faces the challenges of low resolution point cloud estimation and sparsity, which seriously restricts the system detection performance. This study proposes an innovative radar point cloud generation method combining compressed sensing and a depth camera to improve the accuracy and robustness of the fall detection system. Specifically, the study reformulates radar point cloud direction of arrival (DOA) estimation as a linear inverse problem and solves it using compressed sensing (CS) with the fast approximate message passing (AMP) algorithm, significantly improving point cloud positional resolution compared with the traditional fast Fourier transform (FFT) method. Subsequently, an Encoder-Decoder network based on the attention mechanism is designed to effectively enhance the density and expression ability of the point cloud by capturing the local features of the radar point cloud. The depth camera in this article is only used in the network training process. In the actual fall detection stage, the system only uses radar signals for classification. The experimental results verify the advantages of the proposed method in indoor fall detection. Compared with the traditional FFT-based point cloud generation results, the detection accuracy is improved from ∼ 91% to ∼ 96%. The innovative method proposed in this paper provides an efficient, economical, and easy-to-deploy technical solution for fall detection systems in the smart home environment, which has significant potential applications.

  • Enhancing SIL Radar Efficiency for Wrist Pulse Detection: A Comparator-Counter Approach

    by Haotian Shi, Zhi Zheng, Bo Wang, Yongxin Guo

    In this work, a novel approach to wrist pulse detection using a Self-Injection-Locked (SIL) radar system is proposed, replacing the traditional Analog-to-Digital Converters (ADC) based design with a comparator-counter system. The proposed system simplifies the signal processing pipeline by enabling direct hardware-level detection of heartbeat events using binary outputs, thereby reducing power consumption and minimizing data storage requirements. This hardware innovation is complemented by a Signal Quality Index (SQI) algorithm tailored for binary data, which filters the detected signals to improve the accuracy and reliability of heart rate detection. The system’s performance has been evaluated through extensive experiments. Results show that the system maintains good accuracy in heartbeat detection, demonstrating its potential for real-time, long-term monitoring.

  • Contactless High Dynamic-Range Blood Pressure Estimation by Pulse Morphological Features Based on Accurate Doppler Radar Detection

    by Zhi Zheng, Shuqin Dong, Haotian Shi, Bo Wang, Zhiying Zhou, Yongxin Guo

    Blood pressure (BP) can be estimated contactlessly based on Doppler wrist pulse (DWP) detection. However, this technique faces the challenge of interferences from the respiratory and its harmonic components, which can limit the accuracy of the BP estimation. This article first presents an adaptive respiratory harmonic filtering (ARHF) technique, aiming to mitigate the interference of respiration on the wrist pulse signal. Also, a customized 24-GHz continuous wave radar system with high linearity and a high gain antenna is used for better DWP detection. Second, a novel radar-based BP estimation model based on multidimensional morphological features extraction is proposed for high-accuracy and high-robustness BP estimation. In a stationary BP estimation experiment with eight subjects over three consecutive days, the proposed method demonstrates an average mean error and standard deviation of 2.60 $\pm$ 7.89 mmHg and 1.01 $\pm$ 2.84 mmHg in the sitting posture for systolic and diastolic blood pressure (SBP and DBP), respectively, achieving the highest estimation accuracy among the recent contactless radar-based BP detection. Additionally, a specific BP fluctuation range experiment is conducted to continuously measure BP, including varying BP fluctuations across five stages. In the worst case scenario, the proposed method exhibits SBP and DBP errors of 2.50 $\pm$ 2.98 and 8.34 $\pm$ 9.86 mmHg, respectively, affirming the robustness of the proposed technique. The experimental findings highlight the feasibility and reliability of the DWP extraction and subsequent contactless BP estimation techniques in the healthcare domain.


  • Microwave Wide-Area Self-Injection-Locked Radar for Wrist Pulse Detection

    by Haotian Shi, Xiaoyu Zhang, Zhi Zheng, Bo Wang, Xianzhong Tian, Yongxin Guo

    Radar-based near-field wrist pulse detection systems currently face robustness challenges, particularly when dealing with different subjects and alignment discrepancies. These limitations restrict the applicability of such systems in practical settings. Addressing these challenges, this article introduces a wide-area self-injection-locked (WASIL) radar system to enhance near-field wrist pulse detection performance. The proposed system integrates a complementary split-ring resonator (CSRR) antenna array with a substrate-integrated waveguide (SIW) filter, which broadens the detection range and improves the system’s robustness against different subjects and alignment discrepancies, which are commonly faced in traditional self-injection-locked (SIL) radar applications. In addition, a simulation model of the CSRR antenna, which incorporates customized dielectric constant parameters of the skin, has been established to simulate the dynamic effects of wrist pulse on antenna performance. Experimental results confirm that the WASIL system markedly improves pulse detection capabilities across extensive areas. The detection range has been increased by 255.6% in comparison to the most effective SIL system currently available, which utilizes a single CSRR. This expansion in detection range and demodulation capability improves the system’s robustness, allowing for reliable operation in wrist pulse detection.


  • Radar-Based Short-Time Frequency Accumulation for Masked Fall Detection

    by Zhi Zheng, Bo Wang, Zhiying Zhou, Yongxin Guo

    Masked situations, prevalent in complex scenarios involving multiple people or objects, can be defined as the case where the line of sight between radar and a target is partially obstructed. These situations, with degraded information received by radar, bring challenges for fall detection using conventional approaches. This paper introduces a novel approach to detecting falls in masked scenarios using a millimeter-wave (mmWave) radar. The proposed approach combines two main features extracted from the radar signals: a) the Pattern-Contour-Confined DC-Corrected Doppler time (PCC-DCDT) map, generated from DC-corrected radar signals; b) the Short-Time Frequency Accumulation (STFA), proposed for enhancement of the weakened information in masked situations. Experimental results demonstrate that the combination of the PCC-DCDT map and STFA improves the precision and reliability in masked situations. This exploration work on masked fall scenarios adapts radar sensors to realistic indoor environments with improved accuracy, providing sufficient detection robustness for ubiquitous healthcare applications.


  • Millimeter-Wave Frequency Modulated Continuous Wave Radar-Based Soft Fall Detection Using Pattern Contour-Confined Doppler-Time Maps

    by Bo Wang, Zhi Zheng, Yong-Xin Guo

    Fall accidents are one of the leading causes of non-natural death of older people. It is necessary to design and implement fall detection systems in older people’s homes. Among all indoor fall detection approaches, radar-based methods are considered one of the optimum solutions. In this paper, a millimetre-wave frequency modulated continuous wave (FMCW) radar-based fall detection method using pattern contour-confined Doppler-time (PCC-DT) maps is proposed. The soft fall motions, which can lead to missed detections, are studied and analyzed. When Doppler-time (DT) maps are used to interpret different motions, the redundant information and outliers can cause detection errors. The proposed PCC-DT map can diminish the superfluous information and remove outlier points to improve detection accuracy. The experimental results show that the proposed method can detect sudden and soft fall motions with high accuracy, sensitivity, and specificity.