YYYue Yin

Yue Yin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yue Yin has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Research and Application of Inertial Demister: An Overview

    by Luan Yi-Gang, Zhang Li-Min, Yan Lan-Yi, Yin Yue, Sun Tao

  • Numerical investigation on heat transfer performance of matrix cooling channels for turbine trailing edges

    by Songsong Qiao, Qiang Wang, Lanyi Yan, Hao Fu, Yue Yin

    The paper investigated numerically the heat transfer and pressure loss characteristics of the converging matrix cooling channels for turbine trailing edges with response surface method. The three selected design factors are scale factor ( SF), rib inclination angle ( α) and channel wedge angle ( β). The discussed range for the design factors, SF, α and β, are 2.5–10; 30°–60° and 1.5°–2.5°. And the investigated Reynolds number range is from 15,000 to 40,000. The turbulence model selected was SST k- ω model. It is newly found that the heat transfer and pressure loss characteristics of the converging matrix cooling channels depend heavily on the scaling effect. The matrix cooling channels with larger scale factor generally present higher heat transfer enhancement, higher pressure loss and lower overall thermal performance. In addition, the converging matrix cooling channels with smaller rib inclination angle and larger channel wedge angle present higher heat transfer enhancement and larger pressure loss. Among all the 13 cases, Case 9 with SF = 2.5, α = 45° and β = 1.5° has the highest averaged thermal performance factor under 6 Reynolds numbers.


  • Optimization of Rib Shape and Inclination in a Square Duct With Response Surface Methodology

    by Yigang Luan, Lanyi Yan, Yue Yin, Hao Fu

    This article conducts numerical investigation coupled with Reynolds-averaged Navier–Stokes method on detailed flow field and heat transfer characteristics of ribbed channel with symmetric ribs mounted on two walls. The physical domain is modeled by reference to a practical turbine blade internal cooling channel. The effects of three selected geometric factors of ribs, i.e., rib inclination angle, dimensionless rib height, and dimensionless rib pitch, on the flow and heat transfer are investigated by variable-controlled simulations with the Reynolds number ranges from 5000 to 90,000. The parameter ranges are 30 deg ≤ α ≤ 90 deg, 0.5 ≤ e/w ≤ 1.5, and 5 ≤ P/w ≤ 15 with the rib width w fixed at 1 mm. It is newly found that the friction factor does not follow a monotonical trend with respect to the Reynolds number under certain rib configurations. In addition, three-level numerical calculations about three geometric factors as well as the Reynolds number are conducted with the response surface method (RSM). Quadratic regression model for the targeted response, thermal performance factor (TPF), is obtained. The optimal rib shape for the goal of maximizing the channel overall thermal performance turns out to be e/w = 0.5, P/w = 15, and α = 30 deg as Re is fixed at 30,000.


  • Open Access

    Pressure Drop Measurements and Simulations for the Protective Mesh Screen Before the Gas Turbine Compressor

    by L X Nie, Y Yin, L Y Yan, S W Zhou

    This paper characterizes the pressure drop of incompressible airflow when passing by a metal mesh screen which acts as a protection from sucking foreign solid matters before the gas turbine compressor. The wire diameter is 1.2mm and the mesh number is 3. Two experiments are conducted in different time period of a day to guarantee the experimental repeatability. The experimental data are used in regression analysis to obtain a quadratic correlation between the pressure drop across the screen and the fluid velocity. Numerical simulations are utilized to investigate detailed velocity and pressure fields around the wires and the Standard k-ε turbulence model is used. The results show that the fluid suffers from around 140Pa and 250Pa total pressure drop at the velocity of 20m/s and 30m/s respectively. The pressure closely upstream of the wires is as high as 4 times of the inlet flow level, while wide negative pressure regions are observed downstream of the wires resulting from fluid stagnation, reverse flow and recirculation. The empirical correlation obtained in the paper has a high confidence level and can be used in calculating the overall pressure drop of the gas turbine air intake system.