Kentaro Kawasaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kentaro Kawasaki has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
D. Kuroda
Kobe University Graduate School of Medicine
1 shared publicationDaisuke Kuroda
Kobe University Graduate School of Medicine
1 shared publicationK. Kanemitsu
Kobe University Graduate School of Medicine
1 shared publicationKiyonori Kanemitsu
Kobe University Graduate School of Medicine
1 shared publicationT. Goto
Division of Gastroenterological Surgery, Department of Clinical Molecular Medicine, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
1 shared publicationT. Kamigaki
Kobe University Graduate School of Medicine
1 shared publication
Latest Publications
- 13 March 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (10) , 1796-1799
Experimental evaluation of the mechanical strength of stapling techniques
The single stapling technique (SST) and the double stapling technique (DST) are common anastomoses for rectal cancer. Although many mechanical devices have been developed, the best choice remains unclear. In this study we examined the strength of anastomoses by determining their bursting pressures using an animal model. The intestines of pigs were used. In experiment 1, we compared the bursting pressures for Endo GIA™ 60 blue, Endo GIA™ 60 green, and GIA™ 60 blue. In experiment 2, the bursting pressures of a buttressed cutting site and a nonbuttressed cutting site were measured. In experiment 3, the SST, DST, and DST with buttress using PCEEA™ were performed and the bursting pressures and points of these anastomoses were examined. The bursting pressure of Endo GIA 60 blue (80.3 ± 10.5 mmHg) was significantly higher than that of Endo GIA 60 green (37.3 ± 4.2 mmHg) and GIA 60 blue (31.7 ± 5.8 mmHg) (p < 0.01). When a cut end was buttressed, the bursting pressure (149.6 ± 37.6 mmHg) was significantly higher than that of the nonbuttressed end (75.3 ± 25.1 mmHg) (p < 0.01). The bursting pressure among SST, DST, and DST with buttress was not significantly different. Only one bursting point was the crossing point of the PCEEA and Endo GIA and the bursting pressure of this point was much lower than that of the others. Endo GIA was most suitable for DST. The SST, DST, and DST with buttress had almost the same strength. The crossing point of PCEEA and Endo GIA may be a dangerous point for DST.
- 13 March 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (10) , 1796-1799
Experimental evaluation of the mechanical strength of stapling techniques
The single stapling technique (SST) and the double stapling technique (DST) are common anastomoses for rectal cancer. Although many mechanical devices have been developed, the best choice remains unclear. In this study we examined the strength of anastomoses by determining their bursting pressures using an animal model. The intestines of pigs were used. In experiment 1, we compared the bursting pressures for Endo GIA™ 60 blue, Endo GIA™ 60 green, and GIA™ 60 blue. In experiment 2, the bursting pressures of a buttressed cutting site and a nonbuttressed cutting site were measured. In experiment 3, the SST, DST, and DST with buttress using PCEEA™ were performed and the bursting pressures and points of these anastomoses were examined. The bursting pressure of Endo GIA 60 blue (80.3 ± 10.5 mmHg) was significantly higher than that of Endo GIA 60 green (37.3 ± 4.2 mmHg) and GIA 60 blue (31.7 ± 5.8 mmHg) (p < 0.01). When a cut end was buttressed, the bursting pressure (149.6 ± 37.6 mmHg) was significantly higher than that of the nonbuttressed end (75.3 ± 25.1 mmHg) (p < 0.01). The bursting pressure among SST, DST, and DST with buttress was not significantly different. Only one bursting point was the crossing point of the PCEEA and Endo GIA and the bursting pressure of this point was much lower than that of the others. Endo GIA was most suitable for DST. The SST, DST, and DST with buttress had almost the same strength. The crossing point of PCEEA and Endo GIA may be a dangerous point for DST.
- 7 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (9) , 1508-1511
Evaluation of the mechanical strength and patency of functional end-to-end anastomoses
Although many mechanical devices are being developed for functional end-to-end anastomosis (FETEA), the best choice remains to be determined. The mechanical strength of each device is an important factor associated with anastomotic leakage. In turn, anastomotic patency is related to postoperative stenosis. This study examined the bursting pressure and circumference of several FETEAs.
- 7 February 2007
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (9) , 1508-1511
Evaluation of the mechanical strength and patency of functional end-to-end anastomoses
Although many mechanical devices are being developed for functional end-to-end anastomosis (FETEA), the best choice remains to be determined. The mechanical strength of each device is an important factor associated with anastomotic leakage. In turn, anastomotic patency is related to postoperative stenosis. This study examined the bursting pressure and circumference of several FETEAs.