Malgorzata Ewa Wojtala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Malgorzata Ewa Wojtala has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- David A. Howey
Department of Engineering Science University of Oxford Oxford UK
2 shared publications Mangayarkarasi Nagarathinam
The Faraday Institution, Harwell Campus, Didcot OX11 0RA, United Kingdom
2 shared publicationsAlana Zulke
1 shared publication- Alana Zülke
Department of Chemistry, Lancaster University, Lancaster, LA1 4YB, United Kingdom
1 shared publication Guanchen Li
1 shared publication- Guanchen Li
James Watt School of Engineering University of Glasgow Glasgow G12 8QQ United Kingdom
1 shared publication
Latest Publications
- Open Access
- 1 October 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (10) , 100527
Entropy Profiling for the Diagnosis of NCA/Gr-SiOx Li-Ion Battery Health
Graphite-silicon (Gr-Si) blends have become common in commercial Li-ion battery negative electrodes, offering increased capacity over pure graphite. Lithiation/delithiation of the silicon particles results in volume changes, which may be associated with increased hysteresis of the open circuit potential (OCP). The OCP is a function of both concentration and temperature. Entropy change measurement—which probes the response of the OCP to temperature—offers a unique battery diagnostics tool. While entropy change measurements have previously been applied to study degradation, the implications of Si additives on the entropy profiles of commercial cells have not been explored. Here, we use entropy profiling to track ageing markers in the same way as differential voltage analysis. In addition to lithiation/delithiation hysteresis in the OCP of Gr-Si blends, cells with Gr-Si anodes also exhibit differences in entropy profile depending on cycling direction, reflecting degradation-related morphological changes. For cycled cells, entropy change decreased during discharge, likely corresponding to graphite particles breaking and cracking. However, entropy change during charge increased with cycling, likely due to the volume change of silicon. Over a broad voltage range, these combined effects led to the observed rise in entropy hysteresis with age. Conversely, for calendar aged cells entropy hysteresis remained stable.
- 1 October 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (10) , 100527
Open AccessEntropy Profiling for the Diagnosis of NCA/Gr-SiOx Li-Ion Battery Health
Graphite-silicon (Gr-Si) blends have become common in commercial Li-ion battery negative electrodes, offering increased capacity over pure graphite. Lithiation/delithiation of the silicon particles results in volume changes, which may be associated with increased hysteresis of the open circuit potential (OCP). The OCP is a function of both concentration and temperature. Entropy change measurement—which probes the response of the OCP to temperature—offers a unique battery diagnostics tool. While entropy change measurements have previously been applied to study degradation, the implications of Si additives on the entropy profiles of commercial cells have not been explored. Here, we use entropy profiling to track ageing markers in the same way as differential voltage analysis. In addition to lithiation/delithiation hysteresis in the OCP of Gr-Si blends, cells with Gr-Si anodes also exhibit differences in entropy profile depending on cycling direction, reflecting degradation-related morphological changes. For cycled cells, entropy change decreased during discharge, likely corresponding to graphite particles breaking and cracking. However, entropy change during charge increased with cycling, likely due to the volume change of silicon. Over a broad voltage range, these combined effects led to the observed rise in entropy hysteresis with age. Conversely, for calendar aged cells entropy hysteresis remained stable.
- Open Access
- 16 May 2022
- Published by The Electrochemical Society in ECSarXiv
Entropy profiling for the diagnosis of NCA/Gr-SiOx Li-ion battery health
Graphite-silicon (Gr-Si) blends have become common in commercial Li-ion battery negative electrodes, offering increased capacity over pure graphite. Lithiation/delithiation of the silicon particles results in volume changes, which may be associated with increased hysteresis of the open circuit potential (OCP). The OCP is a function of both concentration and temperature. Entropy change measurement--which probes the response of the OCP to temperature--offers a unique battery diagnostics tool. While entropy change measurements have previously been applied to study degradation, the implications of Si additives on the entropy profiles of commercial cells have not been explored.Here, we use entropy profiling to track ageing markers in the same way as differential voltage analysis. In addition to lithiation/delithiation hysteresis in the OCP of Gr-Si blends, cells with Gr-Si anodes also exhibit differences in entropy profile depending on cycling direction, reflecting degradation-related morphological changes. For cycled cells, entropy change decreased during discharge, likely corresponding to graphite particles breaking and cracking. However, entropy change during charge increased with cycling, likely due to the volume change of silicon. Over a broad voltage range, these combined effects led to the observed rise in entropy hysteresis with age. Conversely, for calendar aged cells entropy hysteresis remained stable.
- 16 May 2022
- Published by The Electrochemical Society in ECSarXiv
Open AccessEntropy profiling for the diagnosis of NCA/Gr-SiOx Li-ion battery health
Graphite-silicon (Gr-Si) blends have become common in commercial Li-ion battery negative electrodes, offering increased capacity over pure graphite. Lithiation/delithiation of the silicon particles results in volume changes, which may be associated with increased hysteresis of the open circuit potential (OCP). The OCP is a function of both concentration and temperature. Entropy change measurement--which probes the response of the OCP to temperature--offers a unique battery diagnostics tool. While entropy change measurements have previously been applied to study degradation, the implications of Si additives on the entropy profiles of commercial cells have not been explored.Here, we use entropy profiling to track ageing markers in the same way as differential voltage analysis. In addition to lithiation/delithiation hysteresis in the OCP of Gr-Si blends, cells with Gr-Si anodes also exhibit differences in entropy profile depending on cycling direction, reflecting degradation-related morphological changes. For cycled cells, entropy change decreased during discharge, likely corresponding to graphite particles breaking and cracking. However, entropy change during charge increased with cycling, likely due to the volume change of silicon. Over a broad voltage range, these combined effects led to the observed rise in entropy hysteresis with age. Conversely, for calendar aged cells entropy hysteresis remained stable.