Julie A. Gilmour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Julie A. Gilmour has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Geetha Mukerji
Department of Medicine, Division of Endocrinology & Metabolism, University of Toronto, Toronto, Ontario, Canada; Women's College Hospital Institute for Health System Solutions and Virtual Care, Toronto, Ontario, Canada; Division of Endocrinology, Women's College Hospital, Toronto, Ontario, Canada
2 shared publicationsAlanna Weisman
Department of Medicine, Division of Endocrinology & Metabolism, University of Toronto, Toronto, Ontario, Canada
1 shared publicationAlyse Goldberg
Department of Medicine, Division of Endocrinology & Metabolism, University of Toronto, Toronto, Ontario, Canada
1 shared publicationCarrie Betel
1 shared publicationDana Whitham
Division of Endocrinology, St. Michael's Hospital, Toronto, Ontario, Canada
1 shared publicationEdward Etchells
Department of Medicine, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada; Centre for Quality Improvement and Patient Safety, University of Toronto, Toronto, Ontario, Canada
1 shared publication
Latest Publications
- 1 March 2022
- Published by SciVision Publishers LLC in Archives of Otolaryngology-Head and Neck Surgery
- Vol. 1 (1) , 1-8
Comparison of ACR-TIRADS to the ATA Guidelines for Thyroid Nodules: A Neck to Neck Comparison
Introduction: The goal of this study was to compare the performance characteristics of the American College of Radiology Thyroid Imaging Reporting and Data System (ACR-TIRADS) and the American Thyroid Association (ATA) systems in identifying malignant thyroid nodules. Methods: In a retrospective chart review, ultrasound images of all thyroid nodules biopsied in 2014- 2015 at a Canadian academic centre were reviewed by two radiologists. The ultrasound characteristics of thyroid nodules were compared with cytologic or pathologic results to determine the positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity for TIRADS and ATA in predicting cancer risk. Clinical course of nodules not requiring follow up or intervention according to ACR-TIRADS was described. Vascularity was added to ACR-TIRADS to determine whether sensitivity of TIRADS improves. Results: A total of 417 thyroid nodules were reviewed, 82% were benign (Bethesda II). The sensitivity, specificity, PPV, and NPV were 97%, 11%, 9%, 98%, and 70%, 29%, 18%, and 81% for ATA and TIRADS, respectively. Of the 10 nodules that did not need ultrasound follow up based on TIRADS criteria, 2 were malignant, the rest were FLUS. If vascularity was added to TIRADS (TIRADS-Vasc), the number of malignant cases missed could have been reduced by 43% (from 7 to 4 cases). Conclusions: TIRADS is more specific but less sensitive than ATA, and misses a small number of malignant nodules. Clinicians need to use their judgement to decide which nodules require biopsy as some malignant cases will be missed using TIRADS alone.
- 1 March 2022
- Published by SciVision Publishers LLC in Archives of Otolaryngology-Head and Neck Surgery
- Vol. 1 (1) , 1-8
Comparison of ACR-TIRADS to the ATA Guidelines for Thyroid Nodules: A Neck to Neck Comparison
Introduction: The goal of this study was to compare the performance characteristics of the American College of Radiology Thyroid Imaging Reporting and Data System (ACR-TIRADS) and the American Thyroid Association (ATA) systems in identifying malignant thyroid nodules. Methods: In a retrospective chart review, ultrasound images of all thyroid nodules biopsied in 2014- 2015 at a Canadian academic centre were reviewed by two radiologists. The ultrasound characteristics of thyroid nodules were compared with cytologic or pathologic results to determine the positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity for TIRADS and ATA in predicting cancer risk. Clinical course of nodules not requiring follow up or intervention according to ACR-TIRADS was described. Vascularity was added to ACR-TIRADS to determine whether sensitivity of TIRADS improves. Results: A total of 417 thyroid nodules were reviewed, 82% were benign (Bethesda II). The sensitivity, specificity, PPV, and NPV were 97%, 11%, 9%, 98%, and 70%, 29%, 18%, and 81% for ATA and TIRADS, respectively. Of the 10 nodules that did not need ultrasound follow up based on TIRADS criteria, 2 were malignant, the rest were FLUS. If vascularity was added to TIRADS (TIRADS-Vasc), the number of malignant cases missed could have been reduced by 43% (from 7 to 4 cases). Conclusions: TIRADS is more specific but less sensitive than ATA, and misses a small number of malignant nodules. Clinicians need to use their judgement to decide which nodules require biopsy as some malignant cases will be missed using TIRADS alone.
- 1 June 2019
- Published by Elsevier in Canadian Journal of Diabetes
- Vol. 43 (4) , 249-255
Implementing Change Ideas, Interpreting Data and Sustaining Change in a Quality Improvement Project
- 1 June 2019
- Published by Elsevier in Canadian Journal of Diabetes
- Vol. 43 (4) , 249-255
Implementing Change Ideas, Interpreting Data and Sustaining Change in a Quality Improvement Project
- 1 February 2019
- Published by Elsevier in Canadian Journal of Diabetes
- Vol. 43 (1) , 13-18
Cystic Fibrosis-Related Diabetes Screening in Adults: A Gap Analysis and Evaluation of Accuracy of Glycated Hemoglobin Levels
- 1 February 2019
- Published by Elsevier in Canadian Journal of Diabetes
- Vol. 43 (1) , 13-18
Cystic Fibrosis-Related Diabetes Screening in Adults: A Gap Analysis and Evaluation of Accuracy of Glycated Hemoglobin Levels
- 14 March 2017
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 23 (3) , 670-675
Promoting resource stewardship: Reducing inappropriate free thyroid hormone testing
Rationale: Free thyroxine (fT4) and free triiodothyronine (fT3) tests are often ordered when not clinically warranted. Preventing laboratory overuse by reducing inappropriate fT4 and fT3 testing is one strategy to promote resource stewardship.Objectives: (1) To characterize the frequency of inappropriate fT4 and fT3 testing and (2) to implement a quality improvement strategy aimed at reducing the number of these tests performed.Methods: Quality improvement tools were used to create sequential change ideas: (1) education of physicians regarding appropriate indications for ordering fT4/fT3 and (2) implementation of a hospital‐wide laboratory and forced‐function system with a reflex fT4. This study was conducted at an academic ambulatory care hospital in Toronto, Canada.The main outcomes were the differences in weekly median number of thyroid‐stimulating hormone, fT4, and fT3 tests performed during the preintervention, education, and reflex periods using the Kruskal‐Wallis test and analysis for special cause variation with statistical process control charts.Results: The median number of fT4/fT3 processed per week was significantly reduced from 90/39 at baseline to 78/34 posteducation and 59/14 postreflex (P < .0001). Comparing preintervention to the reflex period, there was 34% reduction in fT4 and 64% reduction in fT3. The number of processed thyroid‐stimulating hormone tests was stable with only 2% variation. Statistical process control charts demonstrated special cause variation following implementation of the reflex system for both fT4 and fT3.Conclusions and Relevance: Inappropriate testing of free thyroid indices occurs frequently. The implementation of a reflex fT4 strategy after education was feasible in reducing overall testing by 49% and was effective in promoting resource stewardship.
- 14 March 2017
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 23 (3) , 670-675
Promoting resource stewardship: Reducing inappropriate free thyroid hormone testing
Rationale: Free thyroxine (fT4) and free triiodothyronine (fT3) tests are often ordered when not clinically warranted. Preventing laboratory overuse by reducing inappropriate fT4 and fT3 testing is one strategy to promote resource stewardship.Objectives: (1) To characterize the frequency of inappropriate fT4 and fT3 testing and (2) to implement a quality improvement strategy aimed at reducing the number of these tests performed.Methods: Quality improvement tools were used to create sequential change ideas: (1) education of physicians regarding appropriate indications for ordering fT4/fT3 and (2) implementation of a hospital‐wide laboratory and forced‐function system with a reflex fT4. This study was conducted at an academic ambulatory care hospital in Toronto, Canada.The main outcomes were the differences in weekly median number of thyroid‐stimulating hormone, fT4, and fT3 tests performed during the preintervention, education, and reflex periods using the Kruskal‐Wallis test and analysis for special cause variation with statistical process control charts.Results: The median number of fT4/fT3 processed per week was significantly reduced from 90/39 at baseline to 78/34 posteducation and 59/14 postreflex (P < .0001). Comparing preintervention to the reflex period, there was 34% reduction in fT4 and 64% reduction in fT3. The number of processed thyroid‐stimulating hormone tests was stable with only 2% variation. Statistical process control charts demonstrated special cause variation following implementation of the reflex system for both fT4 and fT3.Conclusions and Relevance: Inappropriate testing of free thyroid indices occurs frequently. The implementation of a reflex fT4 strategy after education was feasible in reducing overall testing by 49% and was effective in promoting resource stewardship.