Nadia Shaira Shafii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nadia Shaira Shafii has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Makoto Ohta
Institute of Fluid Science, Tohoku University, Sendai, Japan
2 shared publications - Atsushi Saito
Department of Neurosurgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
1 shared publication Gaku Tanaka
Graduate School of Engineering, Chiba University 2 , 263-8522, Chiba, Japan
1 shared publication- Hitomi Anzai
Institute of Fluid Science, Tohoku University Sendai Japan
1 shared publication - Kahar Osman
Universiti Teknologi Malaysia
1 shared publication - Khalid M. Saqr
Arab Academy for Science Technology and Maritime Transport
1 shared publication
Latest Publications
- 1 August 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 142 (1) , 104381
Effects of wall compliance on pulsatile flow in a full-scale, patient-specific cerebral aneurysm model: Particle image velocimetry experiments
The hemodynamics of elastic cerebral aneurysms are complicated by phenomena that affect the initiation and the progress of each aneurysm. The blood vessel deforms with pulsatile flow. In a phantom, however, it remains unclear whether the wall compliance can be neglected. In our previous study, the flow structure at another plane oriented perpendicular to the median plane was not clarified. In the approach presented here, an identical phantom is used for both the rigid and elastic wall models by adjusting the surrounding fluid when immersed in a bath. For this purpose, the full-scale phantom of an aneurysm was fabricated using a silicone elastomer. The hemodynamic factors at the orthogonal planes in the non-deformable and deformable models of the bifurcation in the middle cerebral artery were examined. Using two-dimensional particle image velocimetry, the flow velocity, the wall shear stress (WSS), the WSS gradient (WSSG), and the turbulent kinetic energy (TKE) were measured during pulsatile flow. Overall, the WSSG at the median plane is smaller than that at corresponding perpendicular plane. Additionally, the TKE in the deformable model is smaller than that in the non-deformable model. Our results have clarified the complex effects of aneurysm wall compliance on these hemodynamic factors.
- 1 August 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 142 (1) , 104381
Effects of wall compliance on pulsatile flow in a full-scale, patient-specific cerebral aneurysm model: Particle image velocimetry experiments
The hemodynamics of elastic cerebral aneurysms are complicated by phenomena that affect the initiation and the progress of each aneurysm. The blood vessel deforms with pulsatile flow. In a phantom, however, it remains unclear whether the wall compliance can be neglected. In our previous study, the flow structure at another plane oriented perpendicular to the median plane was not clarified. In the approach presented here, an identical phantom is used for both the rigid and elastic wall models by adjusting the surrounding fluid when immersed in a bath. For this purpose, the full-scale phantom of an aneurysm was fabricated using a silicone elastomer. The hemodynamic factors at the orthogonal planes in the non-deformable and deformable models of the bifurcation in the middle cerebral artery were examined. Using two-dimensional particle image velocimetry, the flow velocity, the wall shear stress (WSS), the WSS gradient (WSSG), and the turbulent kinetic energy (TKE) were measured during pulsatile flow. Overall, the WSSG at the median plane is smaller than that at corresponding perpendicular plane. Additionally, the TKE in the deformable model is smaller than that in the non-deformable model. Our results have clarified the complex effects of aneurysm wall compliance on these hemodynamic factors.
- 10 May 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 131 (18) , 184701
Characteristic effect of wall elasticity on flow instability and wall shear stress of a full-scale, patient-specific aneurysm model in the middle cerebral artery: An experimental approach
The mechanisms underlying the growth and rupture of aneurysms are poorly understood. Although the wall shear stress (WSS) in elastic aneurysm models is examined using fluid-structure interaction (FSI) simulations, it has not been sufficiently validated using experimental modalities, such as particle image velocimetry (PIV) or phase contrast magnetic resonance imaging (PC-MRI). In this study, we investigated pulsatile flow in an elastic, image-based, patient-specific cerebral aneurysm model using PIV. The phantom model was carefully fabricated using a specialized technique by silicone elastomer. We explored the hemodynamics of the WSS and the kinetic energy cascade (KEC) in the elastic model compared with a rigid model, at the apex of the bifurcation of the middle cerebral artery (MCA) in vitro. The effects of elasticity on the WSS, WSS gradient (WSSG), and tensile strength of the aneurysm wall were also investigated, in addition to the effect of wall elasticity on the KEC compared to a rigid wall. Although the WSSG around the stagnation point had a large positive value, there was no difference between the two models. In particular, wall elasticity suppressed the WSS magnitude around the stagnation point and attenuated the KEC (i.e., the flow fluctuation). Future studies examining KEC frequency and WSS characteristics in a phantom model should consider assessing elasticity.
- 10 May 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 131 (18) , 184701
Characteristic effect of wall elasticity on flow instability and wall shear stress of a full-scale, patient-specific aneurysm model in the middle cerebral artery: An experimental approach
The mechanisms underlying the growth and rupture of aneurysms are poorly understood. Although the wall shear stress (WSS) in elastic aneurysm models is examined using fluid-structure interaction (FSI) simulations, it has not been sufficiently validated using experimental modalities, such as particle image velocimetry (PIV) or phase contrast magnetic resonance imaging (PC-MRI). In this study, we investigated pulsatile flow in an elastic, image-based, patient-specific cerebral aneurysm model using PIV. The phantom model was carefully fabricated using a specialized technique by silicone elastomer. We explored the hemodynamics of the WSS and the kinetic energy cascade (KEC) in the elastic model compared with a rigid model, at the apex of the bifurcation of the middle cerebral artery (MCA) in vitro. The effects of elasticity on the WSS, WSS gradient (WSSG), and tensile strength of the aneurysm wall were also investigated, in addition to the effect of wall elasticity on the KEC compared to a rigid wall. Although the WSSG around the stagnation point had a large positive value, there was no difference between the two models. In particular, wall elasticity suppressed the WSS magnitude around the stagnation point and attenuated the KEC (i.e., the flow fluctuation). Future studies examining KEC frequency and WSS characteristics in a phantom model should consider assessing elasticity.