Mahmoud Ahmed El-Desouky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahmoud Ahmed El-Desouky has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Sherif Hamdy Zawam
Department of Trauma and Orthopedics, Faculty of Medicine, Cairo University, Cairo, Egypt
3 shared publications Amr Samir Rashwan
Department of Trauma and Orthopedics, Faculty of Medicine, Cairo University, Cairo, Egypt
2 shared publications- Ahmed Abdel-Zaher Khater
Ahmed Maher Teaching Hospital, Cairo, Egypt
1 shared publication Ahmed Amin Galal
Department of Trauma and Orthopedics, Faculty of Medicine, Cairo University, Cairo, Egypt
1 shared publication- Ahmed Hazem Abdelazeem
Pelvis Fracture and Arthroplasty Unit, Orthopaedic Department, Kasr Alainy Hospital, Cairo University, Cairo, Egypt
1 shared publication - Ahmed Ibrahim Salem Abolenain
Department of Trauma and Orthopedics, Faculty of Medicine, Cairo University, Cairo, Egypt
1 shared publication
Latest Publications
- Open Access
- 28 October 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (4)
Remnant preservation and stump suturing in anterior cruciate ligament reconstruction reduce tibial tunnel widening without compromising tunnel placement: A computed tomography‐based randomised controlled trial
Purpose: Tunnel widening remains a concern following anterior cruciate ligament reconstruction because it may adversely affect graft incorporation and complicate revision surgery. Remnant preservation has been proposed as a strategy to reduce tunnel widening, but its effect on postoperative tunnel remodelling remains uncertain. This study aimed to determine whether remnant preservation with tibial stump suturing reduces tunnel widening without compromising tunnel placement accuracy. Methods: In this prospective randomised controlled trial, 179 patients undergoing primary anterior cruciate ligament (ACL) reconstruction were randomised to remnant‐preserving reconstruction with tibial stump suturing ( n = 88) or conventional stump resection ( n = 91). Standardised three‐dimensional computed tomography was performed at 2 weeks and 1 year postoperatively. Tibial and femoral tunnel widening were calculated as the percentage change in tunnel diameter between scans, and tunnel placement accuracy was assessed using the computed tomography‐based quadrant method. The incidence of clinically significant tunnel widening (>20%) was also compared. Results: Baseline tunnel diameters were comparable between groups. At 1‐year follow‐up, remnant‐preserving ACL reconstruction resulted in significantly less tibial tunnel widening than stump resection (14.58 ± 4.49% vs. 19.74 ± 4.36%, p < 0.001), with a lower incidence of clinically significant widening (>20%) (11.4% vs. 25.3%; relative risk, 0.45; p = 0.016). Femoral tunnel widening was similar between groups (18.23 ± 2.92% vs. 18.35 ± 2.59%, p = 0.766). No clinically relevant differences in tunnel placement were observed between groups. Conclusion: Remnant‐preserving ACL reconstruction with tibial stump suturing selectively reduces tibial tunnel widening at 12 months without compromising anatomic tunnel placement accuracy. These findings support the use of remnant preservation when preservation of tibial tunnel integrity is a surgical consideration. Level of Evidence: Level I. Trial Registration: ClinicalTrials.gov , NCT07236593; registration date: November 15, 2025 (retrospectively registered).
- 28 October 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (4)
Open AccessRemnant preservation and stump suturing in anterior cruciate ligament reconstruction reduce tibial tunnel widening without compromising tunnel placement: A computed tomography‐based randomised controlled trial
Purpose: Tunnel widening remains a concern following anterior cruciate ligament reconstruction because it may adversely affect graft incorporation and complicate revision surgery. Remnant preservation has been proposed as a strategy to reduce tunnel widening, but its effect on postoperative tunnel remodelling remains uncertain. This study aimed to determine whether remnant preservation with tibial stump suturing reduces tunnel widening without compromising tunnel placement accuracy. Methods: In this prospective randomised controlled trial, 179 patients undergoing primary anterior cruciate ligament (ACL) reconstruction were randomised to remnant‐preserving reconstruction with tibial stump suturing ( n = 88) or conventional stump resection ( n = 91). Standardised three‐dimensional computed tomography was performed at 2 weeks and 1 year postoperatively. Tibial and femoral tunnel widening were calculated as the percentage change in tunnel diameter between scans, and tunnel placement accuracy was assessed using the computed tomography‐based quadrant method. The incidence of clinically significant tunnel widening (>20%) was also compared. Results: Baseline tunnel diameters were comparable between groups. At 1‐year follow‐up, remnant‐preserving ACL reconstruction resulted in significantly less tibial tunnel widening than stump resection (14.58 ± 4.49% vs. 19.74 ± 4.36%, p < 0.001), with a lower incidence of clinically significant widening (>20%) (11.4% vs. 25.3%; relative risk, 0.45; p = 0.016). Femoral tunnel widening was similar between groups (18.23 ± 2.92% vs. 18.35 ± 2.59%, p = 0.766). No clinically relevant differences in tunnel placement were observed between groups. Conclusion: Remnant‐preserving ACL reconstruction with tibial stump suturing selectively reduces tibial tunnel widening at 12 months without compromising anatomic tunnel placement accuracy. These findings support the use of remnant preservation when preservation of tibial tunnel integrity is a surgical consideration. Level of Evidence: Level I. Trial Registration: ClinicalTrials.gov , NCT07236593; registration date: November 15, 2025 (retrospectively registered).
- Open Access
- 21 March 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 1-10
Arthroscopic Bankart repair using trans-glenoid double-loaded grand knots versus double-loaded suture anchors; is there a difference? a randomized controlled study
Background: Anatomical repair of Bankart lesions and restoring the tension of the antero-inferior capsulo-labral complex is the optimum method of surgical treatment with a variety of fixation methods including suture anchors and trans-glenoid sutures. Grand knot technique is a modification of the trans-glenoid sutures technique that can be an alternative to double-loaded suture anchors with a lower cost. We aimed to compare the outcomes and complications of both techniques. Methods: This is a randomized controlled study that was conducted on 200 patients with recurrent anterior glenohumeral dislocation, of whom 170 patients completed at least a three-year follow-up period. Arthroscopic Bankart repair using two double-loaded knotted suture anchors was performed in 78 cases (Group A) while repair was done using two trans-glenoid grand knots in other 92 cases (Group B). Patients were evaluated in terms of range of motion, functional scores (Constant, Rowe, and ASES), and complication rate. Results: The mean operative time was significantly longer in Group B (87.7 ± 24) minutes compared to Group A (61.2 ± 28.1) minutes (P = 0.002). No statistically significant difference was found between both groups regarding postoperative external rotation range of adducted arm, functional scores, and rate of recurrence. Only forward flexion and external rotation of abducted arm were significantly better in Group A (P = 0.005 and < 0.001 respectively). Conclusion: Trans-glenoid double-loaded grand knot technique is an alternative surgical option for the treatment of Bankart lesions with comparable results to double-loaded anchors regarding the functional outcomes and failure rates. Clinical Trial Registration (Retrospectively registered): Registration number: NCT06394609 28-4-2024.
- 21 March 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 1-10
Open AccessArthroscopic Bankart repair using trans-glenoid double-loaded grand knots versus double-loaded suture anchors; is there a difference? a randomized controlled study
Background: Anatomical repair of Bankart lesions and restoring the tension of the antero-inferior capsulo-labral complex is the optimum method of surgical treatment with a variety of fixation methods including suture anchors and trans-glenoid sutures. Grand knot technique is a modification of the trans-glenoid sutures technique that can be an alternative to double-loaded suture anchors with a lower cost. We aimed to compare the outcomes and complications of both techniques. Methods: This is a randomized controlled study that was conducted on 200 patients with recurrent anterior glenohumeral dislocation, of whom 170 patients completed at least a three-year follow-up period. Arthroscopic Bankart repair using two double-loaded knotted suture anchors was performed in 78 cases (Group A) while repair was done using two trans-glenoid grand knots in other 92 cases (Group B). Patients were evaluated in terms of range of motion, functional scores (Constant, Rowe, and ASES), and complication rate. Results: The mean operative time was significantly longer in Group B (87.7 ± 24) minutes compared to Group A (61.2 ± 28.1) minutes (P = 0.002). No statistically significant difference was found between both groups regarding postoperative external rotation range of adducted arm, functional scores, and rate of recurrence. Only forward flexion and external rotation of abducted arm were significantly better in Group A (P = 0.005 and < 0.001 respectively). Conclusion: Trans-glenoid double-loaded grand knot technique is an alternative surgical option for the treatment of Bankart lesions with comparable results to double-loaded anchors regarding the functional outcomes and failure rates. Clinical Trial Registration (Retrospectively registered): Registration number: NCT06394609 28-4-2024.
- Open Access
- 8 January 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 1-11
Arthroscopic-assisted reduction for Developmental Hip Dysplasia (DDH) through the sub-adductor and anterolateral portals; A 24-month follow-up prospective descriptive study
Background: Developmental dysplasia of the hip (DDH) encompasses a spectrum of pathological conditions, including dislocation, subluxation, and deformities of the femoral head and acetabulum. The optimal surgical approach for DDH remains a subject of debate. Successful treatment aims to achieve a stable concentric reduction and prevent future subluxation or dislocation. This study aims to assess the clinical and radiographic outcomes of arthroscopic-assisted surgical reduction of DDH in children aged from 6 months to 5 years old. Methods: This prospective study included 57 patients with DDH (68 involved hips) between January 2019 and May 2021. They were treated with arthroscopic-assisted surgical reduction. Dega osteotomy was needed in 22 cases, femoral osteotomy and or shortening was necessary in 11 cases, and combined pelvic and femoral osteotomies were required in nine cases. We evaluated and followed all the patients clinically and radiologically, using Severin, modified Severin scores, Shenton line, and acetabular index measurement up to 24 months postoperatively. Results: The mean age of the included patients was 26.9 months. The mean operative time was 54.7 (36–90) minutes. Clinical assessment using the modified Severin classification revealed that 53 hips (77.9%) were grade I and 11 hips (16.2%) were grade II at the end of the follow-up. Radiological evaluation using Severin classification revealed that 55 hips (80.9%) were in grade I, and 10 hips (14.7%) were in grade II. There was a statistically significant correlation between clinical and radiological grading (p < 0.001). Hip re-dislocation and avascular necrosis (AVN) were experienced in one and two cases, respectively. Conclusion: These findings suggest that arthroscopic-assisted reduction for DDH, with or without osteotomies, is a promising technique with satisfactory clinical and radiographic outcomes and a low complication rate. However, given the single-center nature of this study and its relatively small sample size, these results should be interpreted with caution. Clinical Trial Registration (Retrospectively registered): Registration number: NCT06520436. 25-7-2024.
- 8 January 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 1-11
Open AccessArthroscopic-assisted reduction for Developmental Hip Dysplasia (DDH) through the sub-adductor and anterolateral portals; A 24-month follow-up prospective descriptive study
Background: Developmental dysplasia of the hip (DDH) encompasses a spectrum of pathological conditions, including dislocation, subluxation, and deformities of the femoral head and acetabulum. The optimal surgical approach for DDH remains a subject of debate. Successful treatment aims to achieve a stable concentric reduction and prevent future subluxation or dislocation. This study aims to assess the clinical and radiographic outcomes of arthroscopic-assisted surgical reduction of DDH in children aged from 6 months to 5 years old. Methods: This prospective study included 57 patients with DDH (68 involved hips) between January 2019 and May 2021. They were treated with arthroscopic-assisted surgical reduction. Dega osteotomy was needed in 22 cases, femoral osteotomy and or shortening was necessary in 11 cases, and combined pelvic and femoral osteotomies were required in nine cases. We evaluated and followed all the patients clinically and radiologically, using Severin, modified Severin scores, Shenton line, and acetabular index measurement up to 24 months postoperatively. Results: The mean age of the included patients was 26.9 months. The mean operative time was 54.7 (36–90) minutes. Clinical assessment using the modified Severin classification revealed that 53 hips (77.9%) were grade I and 11 hips (16.2%) were grade II at the end of the follow-up. Radiological evaluation using Severin classification revealed that 55 hips (80.9%) were in grade I, and 10 hips (14.7%) were in grade II. There was a statistically significant correlation between clinical and radiological grading (p < 0.001). Hip re-dislocation and avascular necrosis (AVN) were experienced in one and two cases, respectively. Conclusion: These findings suggest that arthroscopic-assisted reduction for DDH, with or without osteotomies, is a promising technique with satisfactory clinical and radiographic outcomes and a low complication rate. However, given the single-center nature of this study and its relatively small sample size, these results should be interpreted with caution. Clinical Trial Registration (Retrospectively registered): Registration number: NCT06520436. 25-7-2024.
- 10 August 2022
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 28 (8) , 1427-1432
The relationship between ankle dorsiflexion range of motion, frontal plane projection angle, and patellofemoral pain syndrome
- 10 August 2022
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 28 (8) , 1427-1432
The relationship between ankle dorsiflexion range of motion, frontal plane projection angle, and patellofemoral pain syndrome
- Open Access
- 23 July 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-9
Clinical outcomes in stump-preserving versus stump-sacrificing anterior cruciate ligament reconstruction; a randomized controlled study
Background: Anterior Cruciate ligament (ACL) reconstruction (ACLR) aims to restore the anatomy and function of the knee. Although stump preservation during ACLR could be technically challenging, it may improve the revascularization and proprioceptive function of the graft. In this study, we aimed to compare the functional outcome after ACLR with and without stump preservation. Methods: One hundred and twenty patients with acutely torn ACL and with intact tibial stump were included in this study. Half of them (60 cases) underwent ACLR with stump preservation. The other half (60 cases) had ACLR after total resection of the tibial stump. One hundred and nine out of 120 cases completed their 2 year-follow-up period. All patients were assessed by Tegner activity, Lysholm, and objective International Knee Documentation Committee (IKDC) scores. The side-to-side difference regarding stability was assessed by KT-1000 instrumented Lachman and proprioceptive function was measured by Passive angle reproduction test. Results: There was no statistically significant difference between both groups regarding Tegner activity, Lysholm, and IKDC scores. Knee stability measured by KT-1000 and complication rate also showed no significant difference. But there was a significant difference in proprioception favoring stump preservation. On the other hand, the operative time was significantly shorter with stump resection. There was no significant difference in the complications rate between both groups and there were no cases with stiffness in either group. Conclusion: Stump preservation ACLR is a safe technique that yields equivalent functional outcomes to standard ACLR. However; it provides better proprioception. It is more technically challenging, but in experienced hands; it is easily reproducible. Trial registration: Registration number: NCT05364398. 06/05/2022.
- 23 July 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-9
Open AccessClinical outcomes in stump-preserving versus stump-sacrificing anterior cruciate ligament reconstruction; a randomized controlled study
Background: Anterior Cruciate ligament (ACL) reconstruction (ACLR) aims to restore the anatomy and function of the knee. Although stump preservation during ACLR could be technically challenging, it may improve the revascularization and proprioceptive function of the graft. In this study, we aimed to compare the functional outcome after ACLR with and without stump preservation. Methods: One hundred and twenty patients with acutely torn ACL and with intact tibial stump were included in this study. Half of them (60 cases) underwent ACLR with stump preservation. The other half (60 cases) had ACLR after total resection of the tibial stump. One hundred and nine out of 120 cases completed their 2 year-follow-up period. All patients were assessed by Tegner activity, Lysholm, and objective International Knee Documentation Committee (IKDC) scores. The side-to-side difference regarding stability was assessed by KT-1000 instrumented Lachman and proprioceptive function was measured by Passive angle reproduction test. Results: There was no statistically significant difference between both groups regarding Tegner activity, Lysholm, and IKDC scores. Knee stability measured by KT-1000 and complication rate also showed no significant difference. But there was a significant difference in proprioception favoring stump preservation. On the other hand, the operative time was significantly shorter with stump resection. There was no significant difference in the complications rate between both groups and there were no cases with stiffness in either group. Conclusion: Stump preservation ACLR is a safe technique that yields equivalent functional outcomes to standard ACLR. However; it provides better proprioception. It is more technically challenging, but in experienced hands; it is easily reproducible. Trial registration: Registration number: NCT05364398. 06/05/2022.
- Open Access
- 16 June 2022
- Published by EDP Sciences in SICOT-J
- Vol. 8, 26
Finite element analysis modeling of plates versus intramedullary nails in closed comminuted midshaft tibial fractures
Background: Tibial shaft fractures are usually treated by interlocking nails or plates. The ideal implant choice depends on many variables. Aim: To assess the mechanical behavior of interlocking nails and plates in the treatment of closed comminuted midshaft fractures of the tibia using finite element analysis. Material and methods: This is a prospective study of 50 patients with a mean age of 28.4 years with closed comminuted fractures of the midshaft of the tibia. Data evaluation was done by Finite element analysis (FEA). Fixation was revised in two cases. Results: After load application, there were significant differences in both bending (P = 0.041) and strain percent (P = 0.017), reflecting that interlocking nails were superior to plates. There were also significant differences between titanium and stainless-steel materials in bending (p = 0.041) and strain percent (p = 0.017) after applying load, indicating that titanium was superior to stainless steel. Conclusion: Interlocking nails are superior to plates in treating midshaft tibial fractures. The use of blocking screws may be needed in interlocking nails depending on the pattern and extension of the fracture.
- 16 June 2022
- Published by EDP Sciences in SICOT-J
- Vol. 8, 26
Open AccessFinite element analysis modeling of plates versus intramedullary nails in closed comminuted midshaft tibial fractures
Background: Tibial shaft fractures are usually treated by interlocking nails or plates. The ideal implant choice depends on many variables. Aim: To assess the mechanical behavior of interlocking nails and plates in the treatment of closed comminuted midshaft fractures of the tibia using finite element analysis. Material and methods: This is a prospective study of 50 patients with a mean age of 28.4 years with closed comminuted fractures of the midshaft of the tibia. Data evaluation was done by Finite element analysis (FEA). Fixation was revised in two cases. Results: After load application, there were significant differences in both bending (P = 0.041) and strain percent (P = 0.017), reflecting that interlocking nails were superior to plates. There were also significant differences between titanium and stainless-steel materials in bending (p = 0.041) and strain percent (p = 0.017) after applying load, indicating that titanium was superior to stainless steel. Conclusion: Interlocking nails are superior to plates in treating midshaft tibial fractures. The use of blocking screws may be needed in interlocking nails depending on the pattern and extension of the fracture.
- Open Access
- 11 June 2022
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (9) , 2165-2176
Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference?
Purpose: Two different locking plate designs are now being used for volar plating of the distal radius fractures based on the freedom of screw direction; the fixed-angle, and the variable-angle (polyaxial) plates. We investigated the clinical and radiographic outcomes of both designs. Methods: We reviewed 96 patients with 113 unstable distal radius fractures that were operated on with volar locking plates. The patients’ mean age was 41 years. Fixed-angle volar locking plates were utilized in 65 fractures and variable-angle volar locking plates in 48 fractures through modified Henry approach or extended carpal tunnel approach. Full clinical and radiographic evaluation was done for all patients with a mean follow-up of 14 months. Results: All patients had acceptable clinical and radiographic parameters. The overall functional results (Mayo score, Quick Disability of Arm, Shoulder, and Hand (Q-DASH) score, Range of motion (ROM), and grip strength) were in favor of the variable-angle plate. The radiographic parameters were better with the variable-angle group. The variable-angle group recorded less operative time but more mean image intensifier exposure time. There were two cases of flexor tendon rupture with the fixed-angle group. Fixation with the fixed-angle system needed K-wire augmentation more than the variable-angle group. There was a positive correlation between hand dominance and the final score. Conclusion: Distal radius volar locking plates yield satisfactory results comparable among different designs. In our series, the variable-angle system showed slightly better function and radiographic outcomes. Supplementary K-wires were needed more frequently with the fixed-angle system.
- 11 June 2022
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (9) , 2165-2176
Open AccessVolar locking plate fixation for distal radius fractures: did variable-angle plates make difference?
Purpose: Two different locking plate designs are now being used for volar plating of the distal radius fractures based on the freedom of screw direction; the fixed-angle, and the variable-angle (polyaxial) plates. We investigated the clinical and radiographic outcomes of both designs. Methods: We reviewed 96 patients with 113 unstable distal radius fractures that were operated on with volar locking plates. The patients’ mean age was 41 years. Fixed-angle volar locking plates were utilized in 65 fractures and variable-angle volar locking plates in 48 fractures through modified Henry approach or extended carpal tunnel approach. Full clinical and radiographic evaluation was done for all patients with a mean follow-up of 14 months. Results: All patients had acceptable clinical and radiographic parameters. The overall functional results (Mayo score, Quick Disability of Arm, Shoulder, and Hand (Q-DASH) score, Range of motion (ROM), and grip strength) were in favor of the variable-angle plate. The radiographic parameters were better with the variable-angle group. The variable-angle group recorded less operative time but more mean image intensifier exposure time. There were two cases of flexor tendon rupture with the fixed-angle group. Fixation with the fixed-angle system needed K-wire augmentation more than the variable-angle group. There was a positive correlation between hand dominance and the final score. Conclusion: Distal radius volar locking plates yield satisfactory results comparable among different designs. In our series, the variable-angle system showed slightly better function and radiographic outcomes. Supplementary K-wires were needed more frequently with the fixed-angle system.
- Open Access
- 16 May 2022
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (9) , 2127-2134
Lateral malleolar fractures Weber Type A and B: does percutaneous intramedullary screw confer a solid alternative to the traditional neutralization plate?
Purpose: To compare the clinical results, complication rates, and radiographic outcome between both methods of fixation of lateral malleolar fractures: lateral neutralization plates and intramedullary fully threaded screws. Patients and methods: This prospective case series study involved 73 patients with fractured lateral malleolus of type A, B according to Weber classification, to whom internal fixation was performed by either lateral plate and screws construct (Group A) or intramedullary screw (Group B). All patients were followed up for 12 months at least, with an average follow-up time of 12.7 months. Results: There was no significant difference in the functional outcome score between both groups. The intramedullary screw group had a significantly shorter operative time and time to full union (P<0.001 and =0.006 respectively). There was a relatively higher accuracy of reduction with the plate fixation group, but it was statistically insignificant. There was a relatively fewer complication rate with the use of intramedullary screw fixation compared to plate fixation. Conclusion: The use of intramedullary fixation is a good alternative for plate fixation in low fibular fractures (Weber A and B). Although plate fixation provides an optimal anatomic reconstruction of the fractures, intramedullary fixation may have a lower risk of complications.
- 16 May 2022
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (9) , 2127-2134
Open AccessLateral malleolar fractures Weber Type A and B: does percutaneous intramedullary screw confer a solid alternative to the traditional neutralization plate?
Purpose: To compare the clinical results, complication rates, and radiographic outcome between both methods of fixation of lateral malleolar fractures: lateral neutralization plates and intramedullary fully threaded screws. Patients and methods: This prospective case series study involved 73 patients with fractured lateral malleolus of type A, B according to Weber classification, to whom internal fixation was performed by either lateral plate and screws construct (Group A) or intramedullary screw (Group B). All patients were followed up for 12 months at least, with an average follow-up time of 12.7 months. Results: There was no significant difference in the functional outcome score between both groups. The intramedullary screw group had a significantly shorter operative time and time to full union (P<0.001 and =0.006 respectively). There was a relatively higher accuracy of reduction with the plate fixation group, but it was statistically insignificant. There was a relatively fewer complication rate with the use of intramedullary screw fixation compared to plate fixation. Conclusion: The use of intramedullary fixation is a good alternative for plate fixation in low fibular fractures (Weber A and B). Although plate fixation provides an optimal anatomic reconstruction of the fractures, intramedullary fixation may have a lower risk of complications.