Hong Meng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hong Meng has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Mu-Zi Li
Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, P. R. China
3 shared publicationsQian-Qian Liu
Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, P. R. China
3 shared publicationsLiang Zhang
Department of Cardiac Surgery, State Key Laboratory of Cardiovascular Diseases, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
2 shared publicationsMuzi Li
Department of Echocardiography, State Key Laboratory of Cardiovascular Diseases, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China; Department of Echocardiography, Fuwai Yunnan Cardiovascular Hospital, Kunming, China
2 shared publicationsYan Shen
Department of Echocardiography, Fuwai Yunnan Cardiovascular Hospital Kunming, Kunming, China
2 shared publicationsYi-Ming Gao
Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, P. R. China
2 shared publications
Latest Publications
- Open Access
- 17 January 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (3) , e41162
Iatrogenic diversion of inferior vena cava to the left atrium presented as persistent hypoxemia: Case series
Rationale: The transcatheter closure and atrioseptopexy are the main treatment methods for atrial septal defect (ASD). However, persistent hypoxemia due to iatrogenic diversion of inferior vena cava (IVC) to the left atrium (LA) is reported as a rare complication after ASD closure. Contrast echocardiology is a reliable and powerful tool to detect iatrogenic diversion and identify the etiology accurately. Patient concerns: We reported 2 patients (a 11-year-old boy [Patient 1] and a 39-year-old female [Patient 2]) with persistent hypoxemia and exertional dyspnea after ASD transcatheter closure and robotic atrioseptopexy, respectively. Diagnoses: Contrast echocardiography confirmed the presence of a right-to-left shunt at the atrial level which was presented only in femoral venous contrast injection instead of upper extremity venous contrast injection. Interventions and Outcomes: Subsequent surgical exploration found that the occluder straddling the entry of IVC and the fibrous membrane proliferating along the lower edge of the occlude in the first patient, and the patch improperly linked to the Eustachian valve in the second patient. The misoperation led to IVC partially draining into LA. After the surgeries, both of them had their hypoxic symptoms relieved. Lessons: Persistent unexplained hypoxemia after ASD closure might be considered to result from a right-to-left shunt. An iatrogenic right-to-left shunt flow from the IVC to the LA was usually caused by the misplaced interatrial occluder or patch. Transthoracic agitated saline contrast echocardiography via combined peripheral venous access has the well-performed capability to hint some insidious right-to-left shunts and guides clinical therapy as soon as possible.
- 17 January 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (3) , e41162
Open AccessIatrogenic diversion of inferior vena cava to the left atrium presented as persistent hypoxemia: Case series
Rationale: The transcatheter closure and atrioseptopexy are the main treatment methods for atrial septal defect (ASD). However, persistent hypoxemia due to iatrogenic diversion of inferior vena cava (IVC) to the left atrium (LA) is reported as a rare complication after ASD closure. Contrast echocardiology is a reliable and powerful tool to detect iatrogenic diversion and identify the etiology accurately. Patient concerns: We reported 2 patients (a 11-year-old boy [Patient 1] and a 39-year-old female [Patient 2]) with persistent hypoxemia and exertional dyspnea after ASD transcatheter closure and robotic atrioseptopexy, respectively. Diagnoses: Contrast echocardiography confirmed the presence of a right-to-left shunt at the atrial level which was presented only in femoral venous contrast injection instead of upper extremity venous contrast injection. Interventions and Outcomes: Subsequent surgical exploration found that the occluder straddling the entry of IVC and the fibrous membrane proliferating along the lower edge of the occlude in the first patient, and the patch improperly linked to the Eustachian valve in the second patient. The misoperation led to IVC partially draining into LA. After the surgeries, both of them had their hypoxic symptoms relieved. Lessons: Persistent unexplained hypoxemia after ASD closure might be considered to result from a right-to-left shunt. An iatrogenic right-to-left shunt flow from the IVC to the LA was usually caused by the misplaced interatrial occluder or patch. Transthoracic agitated saline contrast echocardiography via combined peripheral venous access has the well-performed capability to hint some insidious right-to-left shunts and guides clinical therapy as soon as possible.
- Open Access
- 27 August 2024
- Published by Springer Nature in BMC Pediatrics
- Vol. 24 (1) , 1-10
Accurate prenatal diagnosis of coarctation of the aorta by 3-step echocardiographic diagnostic protocol
Background: Coarctation of the aorta (CoA) is the most common undiagnosed congenital heart defect during prenatal screening. High false positive and false negative rates seriously affect prenatal consultation and postnatal management. The objective of the study was to assess the utility of various measurements to predict prenatal CoA and to derive a diagnostic algorithm. Methods: One hundred and fifty-four fetuses with suspected CoA who presented at Fuwai Hospital between December 2017 and August 2021 were enrolled and divided into confirmed CoA cases (n = 47) and false positive cases (n = 107), according to their postnatal outcomes. The transverse aortic arch, isthmus, and descending aorta were measured in the long-axis view of the aortic arch. The angle between the transverse aortic arch (TAO) and the descending aortic arch (DAO) was defined as the TAO-DAO angle and measured in the long axis or sagittal view. Based on the database in GE Voluson E10 and the formula (Z = $$\frac{\text{x}-{\mu }}{\alpha }$$ ), the standard score (Z-score) of the dimensions of the aorta were calculated in relation to the gestational age. The main echocardiographic indices were combined to design a 3-step diagnostic protocol. The TAO-DAO angle was used as the first step in the diagnostic model. The diameter of the transverse arch and the Z-score of the isthmus were the second step. The third-step indices included a Z-score of the transverse arch, diameter of the isthmus, distance from the left subclavian artery (LSA) to left common carotid artery (LCCA), the ratio of isthmus diameter and LSA diameter and ratio of the distances (the distance between the LSA and LCCA to the distance between the right innominate artery and LCCA). The receiver operating characteristic (ROC) curve determined the predictive capability of each diagnostic parameter, and the kappa test determined the diagnostic accuracy of the proposed model. Results: The cases with confirmed CoA had thinner transverse arches (1.92 ± 0.32 mm vs. 3.06 ± 0.67 mm, P = 0.0001), lower Z-scores of the isthmus (-8.97 ± 1.45 vs. -5.65 ± 1.60, P = 0.0001), smaller TAO-DAO angles (105.54 ± 11.51° vs. 125.29 ± 8.97°, P = 0.0001) and larger distance between the LSA and LCCA (4.45 ± 1.75 mm vs. 2.74 ± 1.07 mm, P = 0.0001) than the false positive cases. The area under the curve (AUC) was 0.947 (95% CI 0.91–0.98) for the TAO-DAO angle ≤ 115.75°, 0.942 (95% CI 0.91–0.98) for the transverse arch diameter ≤ 2.31 mm, 0.937 (95% CI 0.90–0.98) for the Z-score of the isthmus ≤ -7.5, and 0.975 (95% CI 0.95–1.00) for the 3-step diagnostic protocol with 97.8% sensitivity and 97.2% specificity. The kappa test showed that the model’s diagnostic accuracy was consistent with postnatal outcomes (kappa value 0.936, P = 0.0001). Conclusions: The 3-step diagnostic protocol included the three most useful measurements and the additional indices with appropriate cut-off values. The algorithm is useful for the detection of aortic coarctation in fetuses with a high degree of accuracy. Trial registration: Retrospectively registered.- 27 August 2024
- Published by Springer Nature in BMC Pediatrics
- Vol. 24 (1) , 1-10
Open AccessAccurate prenatal diagnosis of coarctation of the aorta by 3-step echocardiographic diagnostic protocol
Background: Coarctation of the aorta (CoA) is the most common undiagnosed congenital heart defect during prenatal screening. High false positive and false negative rates seriously affect prenatal consultation and postnatal management. The objective of the study was to assess the utility of various measurements to predict prenatal CoA and to derive a diagnostic algorithm. Methods: One hundred and fifty-four fetuses with suspected CoA who presented at Fuwai Hospital between December 2017 and August 2021 were enrolled and divided into confirmed CoA cases (n = 47) and false positive cases (n = 107), according to their postnatal outcomes. The transverse aortic arch, isthmus, and descending aorta were measured in the long-axis view of the aortic arch. The angle between the transverse aortic arch (TAO) and the descending aortic arch (DAO) was defined as the TAO-DAO angle and measured in the long axis or sagittal view. Based on the database in GE Voluson E10 and the formula (Z = $$\frac{\text{x}-{\mu }}{\alpha }$$ ), the standard score (Z-score) of the dimensions of the aorta were calculated in relation to the gestational age. The main echocardiographic indices were combined to design a 3-step diagnostic protocol. The TAO-DAO angle was used as the first step in the diagnostic model. The diameter of the transverse arch and the Z-score of the isthmus were the second step. The third-step indices included a Z-score of the transverse arch, diameter of the isthmus, distance from the left subclavian artery (LSA) to left common carotid artery (LCCA), the ratio of isthmus diameter and LSA diameter and ratio of the distances (the distance between the LSA and LCCA to the distance between the right innominate artery and LCCA). The receiver operating characteristic (ROC) curve determined the predictive capability of each diagnostic parameter, and the kappa test determined the diagnostic accuracy of the proposed model. Results: The cases with confirmed CoA had thinner transverse arches (1.92 ± 0.32 mm vs. 3.06 ± 0.67 mm, P = 0.0001), lower Z-scores of the isthmus (-8.97 ± 1.45 vs. -5.65 ± 1.60, P = 0.0001), smaller TAO-DAO angles (105.54 ± 11.51° vs. 125.29 ± 8.97°, P = 0.0001) and larger distance between the LSA and LCCA (4.45 ± 1.75 mm vs. 2.74 ± 1.07 mm, P = 0.0001) than the false positive cases. The area under the curve (AUC) was 0.947 (95% CI 0.91–0.98) for the TAO-DAO angle ≤ 115.75°, 0.942 (95% CI 0.91–0.98) for the transverse arch diameter ≤ 2.31 mm, 0.937 (95% CI 0.90–0.98) for the Z-score of the isthmus ≤ -7.5, and 0.975 (95% CI 0.95–1.00) for the 3-step diagnostic protocol with 97.8% sensitivity and 97.2% specificity. The kappa test showed that the model’s diagnostic accuracy was consistent with postnatal outcomes (kappa value 0.936, P = 0.0001). Conclusions: The 3-step diagnostic protocol included the three most useful measurements and the additional indices with appropriate cut-off values. The algorithm is useful for the detection of aortic coarctation in fetuses with a high degree of accuracy. Trial registration: Retrospectively registered. - Open Access
- 5 June 2024
- Published by Elsevier in Hellenic Journal of Cardiology
- Vol. 86, 80-90
Biventricular function after Ebstein anomaly repair from a single-center echocardiography study
- 5 June 2024
- Published by Elsevier in Hellenic Journal of Cardiology
- Vol. 86, 80-90
Open AccessBiventricular function after Ebstein anomaly repair from a single-center echocardiography study
- Open Access
- 1 September 2022
- Published by Springer Nature in Research Square
Accurate Prenatal Diagnosis of Coarctation of the Aorta by Three-step Echocardiographic Diagnostic Model
Background Coarctation of the aorta (CoA) is the most common undiagnosed congenital heart defect during prenatal screening. High false positive and false negative rates seriously affect prenatal consultation and postnatal management. The objective of the study was to assess the utility of various measurements to predict prenatal CoA and to derive a diagnostic algorithm. Methods One hundred and fifty-four fetuses with suspected CoA who presented at Fuwai Hospital between December 2017 and August 2021 were enrolled and divided into confirmed CoA cases (47) and false-positive cases (107), according to their postnatal outcomes. Fetal echocardiographic measurements included the cardiac chambers sizes, valve annular diameters, and ascending aorta and pulmonary artery dimensions. The corresponding gestational age-related Z-scores were collected. The diameter of the transverse aortic arch and the aortic isthmus were measured. The TAO-DAO angle between the transverse aortic arch and isthmus was also measured. The receiver operating characteristic curve determined the predictive capability of each diagnostic parameter, and the kappa test determined the diagnostic accuracy of the proposed model.Results Confirmed CoA cases had thinner transverse arches (1.92 ± 0.32 mm vs. 3.06 ± 0.67 mm, P = 0.0001), lower Z-scores of the isthmus (-8.97 ± 1.45 vs. -5.65 ± 1.60, P = 0.0001), smaller TAO-DAO angles (105.54 ± 11.51° vs. 125.29 ± 8.97°, P = 0.0001) and larger distance between the left subclavian artery and left common carotid artery (4.45 ± 1.75 mm vs. 2.74 ± 1.07 mm, P = 0.0001) than the false-positive cases. The area under the curve was 0.947 (95% CI 0.91–0.98) for the TAO-DAO angle, 0.942 (95% CI 0.91–0.98) for the transverse arch diameter, and 0.937 (95% CI 0.90–0.98) for the Z-score of the isthmus. Three important echocardiographic indices were combined to derive a three-step echocardiographic diagnostic model. The kappa test showed that the model’s diagnostic accuracy was consistent with postnatal outcomes (kappa value 0.936, P = 0.0001).Conclusions The three step approach included the three most useful measurements and the five additional indices with appropriate cut-off values. The algorithm optimizes the diagnosis of fetal CoA and is clinically feasible.Trial registration: retrospectively registered.
- 1 September 2022
- Published by Springer Nature in Research Square
Open AccessAccurate Prenatal Diagnosis of Coarctation of the Aorta by Three-step Echocardiographic Diagnostic Model
Background Coarctation of the aorta (CoA) is the most common undiagnosed congenital heart defect during prenatal screening. High false positive and false negative rates seriously affect prenatal consultation and postnatal management. The objective of the study was to assess the utility of various measurements to predict prenatal CoA and to derive a diagnostic algorithm. Methods One hundred and fifty-four fetuses with suspected CoA who presented at Fuwai Hospital between December 2017 and August 2021 were enrolled and divided into confirmed CoA cases (47) and false-positive cases (107), according to their postnatal outcomes. Fetal echocardiographic measurements included the cardiac chambers sizes, valve annular diameters, and ascending aorta and pulmonary artery dimensions. The corresponding gestational age-related Z-scores were collected. The diameter of the transverse aortic arch and the aortic isthmus were measured. The TAO-DAO angle between the transverse aortic arch and isthmus was also measured. The receiver operating characteristic curve determined the predictive capability of each diagnostic parameter, and the kappa test determined the diagnostic accuracy of the proposed model.Results Confirmed CoA cases had thinner transverse arches (1.92 ± 0.32 mm vs. 3.06 ± 0.67 mm, P = 0.0001), lower Z-scores of the isthmus (-8.97 ± 1.45 vs. -5.65 ± 1.60, P = 0.0001), smaller TAO-DAO angles (105.54 ± 11.51° vs. 125.29 ± 8.97°, P = 0.0001) and larger distance between the left subclavian artery and left common carotid artery (4.45 ± 1.75 mm vs. 2.74 ± 1.07 mm, P = 0.0001) than the false-positive cases. The area under the curve was 0.947 (95% CI 0.91–0.98) for the TAO-DAO angle, 0.942 (95% CI 0.91–0.98) for the transverse arch diameter, and 0.937 (95% CI 0.90–0.98) for the Z-score of the isthmus. Three important echocardiographic indices were combined to derive a three-step echocardiographic diagnostic model. The kappa test showed that the model’s diagnostic accuracy was consistent with postnatal outcomes (kappa value 0.936, P = 0.0001).Conclusions The three step approach included the three most useful measurements and the five additional indices with appropriate cut-off values. The algorithm optimizes the diagnosis of fetal CoA and is clinically feasible.Trial registration: retrospectively registered.
- 16 May 2022
- Published by Elsevier in Journal of Cardiology
- Vol. 80 (3) , 261-267
Clinical and echocardiographic characteristics of cardiac blood cysts
- 16 May 2022
- Published by Elsevier in Journal of Cardiology
- Vol. 80 (3) , 261-267
Clinical and echocardiographic characteristics of cardiac blood cysts
- Open Access
- 1 January 2022
- Published by Tech Science Press in Congenital Heart Disease
- Vol. 17 (3) , 231-244
Combined Echocardiography and Lung Ultrasound for Extubation Outcome Prediction in Children after Cardiac Surgery
Background: Children are at risk of extubation failure after congenital heart disease surgery. Such cases should be identified to avoid possible adverse consequences of failed extubation. This study aimed to identify ultrasound predictors of successful extubation in children who underwent cardiac surgery. Methods: Children aged 3 months to 6 years who underwent cardiac surgery (if they were intubated for >6 h and underwent a spontaneous breathing trial) were included in this study. Results: We included 83 children who underwent surgery for congenital heart disease. Transthoracic echocardiography and lung ultrasound were performed immediately before spontaneous breathing trials. Upon spontaneous breathing trial completion, respiratory parameters, including arterial blood gas analysis and frequency-to-tidal volume ratio, were similarly recorded. For outcome assessment, all children were followed up for 48 h after extubation. We successfully extubated 57 children (68.7%). These children were significantly older and weighed more but had shorter aortic cross-clamp and cardiopulmonary bypass times. Children who could not be weaned or extubated had prolonged total mechanical ventilation and pediatric intensive care unit stay. In the multivariate regression analysis, a lung ultrasound score ≥12 and ejection fraction ≥40% immediately before spontaneous breathing trials were the only independent predictors of successful extubation. When combined, the lung ultrasound score and an ejection fraction ≥40% showed a better diagnostic performance than every other isolated variable (lung ultrasound, N-terminal-pro-B-type natriuretic peptide, and frequency-to-tidal volume ratio). Conclusions: The combination of lung ultrasound and transthoracic echocardiography immediately before the spontaneous breathing trial effectively predicts extubation outcomes in children after cardiac surgery.
- 1 January 2022
- Published by Tech Science Press in Congenital Heart Disease
- Vol. 17 (3) , 231-244
Open AccessCombined Echocardiography and Lung Ultrasound for Extubation Outcome Prediction in Children after Cardiac Surgery
Background: Children are at risk of extubation failure after congenital heart disease surgery. Such cases should be identified to avoid possible adverse consequences of failed extubation. This study aimed to identify ultrasound predictors of successful extubation in children who underwent cardiac surgery. Methods: Children aged 3 months to 6 years who underwent cardiac surgery (if they were intubated for >6 h and underwent a spontaneous breathing trial) were included in this study. Results: We included 83 children who underwent surgery for congenital heart disease. Transthoracic echocardiography and lung ultrasound were performed immediately before spontaneous breathing trials. Upon spontaneous breathing trial completion, respiratory parameters, including arterial blood gas analysis and frequency-to-tidal volume ratio, were similarly recorded. For outcome assessment, all children were followed up for 48 h after extubation. We successfully extubated 57 children (68.7%). These children were significantly older and weighed more but had shorter aortic cross-clamp and cardiopulmonary bypass times. Children who could not be weaned or extubated had prolonged total mechanical ventilation and pediatric intensive care unit stay. In the multivariate regression analysis, a lung ultrasound score ≥12 and ejection fraction ≥40% immediately before spontaneous breathing trials were the only independent predictors of successful extubation. When combined, the lung ultrasound score and an ejection fraction ≥40% showed a better diagnostic performance than every other isolated variable (lung ultrasound, N-terminal-pro-B-type natriuretic peptide, and frequency-to-tidal volume ratio). Conclusions: The combination of lung ultrasound and transthoracic echocardiography immediately before the spontaneous breathing trial effectively predicts extubation outcomes in children after cardiac surgery.