Vernon Seth Crasto has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modeling and Analysis of Current-Carrying Coils Versus Rotating Magnet Transmitters for Low-Frequency Electrodynamic Wireless Power Transmission

    by Vernon S. Crasto, Nicolas Garraud, Matthew G. Stormant, David P. Arnold

    Current-carrying coils and rotating permanent magnets can be used to create time-varying excitation magnetic fields for electrodynamic wireless power transmission (EWPT). Both types of transmitters produce low-frequency, time-varying fields at the locations of the receiver, but with fundamental differences. A coil transmitter produces a uniaxial magnetic field, where the direction of the field is along a single axis, but the amplitude varies in a bipolar fashion. In contrast, a rotating magnet transmitter produces a rotating magnetic field, with the amplitude varying in two orthogonal directions. Building on prior work for coil transmitters, this manuscript presents the modeling and a simulation framework for rotating magnet transmitters. The performance of an EWPT system is then studied both theoretically and experimentally for both transmitter types. For the same B-field amplitude (501 µT) and a fixed transmitter-receiver distance of 12 cm, a receiver driven by a coil transmitter produces 38 mW, whereas the same receiver driven by a rotating magnet transmitter produces 149 mW, nearly four times higher. This power increase is a result of 50% higher receiver rotation speeds using the rotating magnet transmitter. The power transfer efficiency is also six times higher for the rotating magnet transmitter.


  • Open Access

    Modeling and analysis of current-carrying coils verus rotating magnet transmitters for electrodynamic wireless power transmission

    by Vernon Crasto, Nicolas Garraud, Matthew G. Stormant, David P. Arnold

    Current-carrying coils and rotating permanent magnets can be used to create time-varying excitation magnetic fields for electrodynamic wireless power transmission (EWPT). Both types of transmitters produce low-frequency, time-varying fields at the location of the receiver, but with fundamental differences. A coil transmitter produces a uniaxial magnetic field, where the direction of the field is along a single axis, but the amplitude varies in a bipolar fashion. In contrast, a rotating magnet transmitter produces a rotating magnetic field, with the amplitude varying in two orthogonal directions. Building on prior work for coil transmitters, this manuscript presents the modeling and a simulation framework for rotating magnet transmitters. The performance of an EWPT system is then studied both theoretically and experimentally for both transmitter types. For the same B-field amplitude (501 𝜇T) and a fixed transmitter-receiver distance of 12 cm, a receiver driven by a coil transmitter produces 38 mW, whereas the same receiver driven by a rotating magnet transmitter produces 149 mW, nearly 4 times higher. This power increase is a result of ~50% higher receiver rotation speeds using the rotating magnet transmitter. The power transfer efficiency is also 6 times higher for the rotating magnet transmitter.

  • Open Access

    Finite Element Analysis of Cornea and Lid Wiper during Blink, with and without Contact Lens

    by Vivek Suganthan Ramasubramanian, S. Meenatchi Sundaram, Rinu Thomas, S. Ve. Ramesh, B. Raghuvir Pai, Manali Hazarika, Shah Mohammed Abdul Khader, Rakshath G. Poojary, H. Girish, Vernon Seth Crasto

    Ocular surface disorders such as Lid Wiper Epitheliopathy (LWE), Superior Epithelial Arcuate Lesion (SEAL), and contact lens-induced Limbal Stem Cell Deficiency (LSCD) as well as Superior Limbic Keratoconjunctivitis (SLK) affect one’s quality of life. Hence, it is imperative to investigate the underlying causes of these ocular surface disorders. During blink, the undersurface of the eyelid tends to interact with the cornea and the conjunctiva. The presence of a contact lens can add to the biomechanical frictional changes on these surfaces. To estimate these changes with and without a contact lens, a finite element model (FEM) of the eyelid wiper, eyeball, and contact lens was developed using COMSOL Multiphysics. Biomechanical properties such as von Mises stress (VMS) and displacement were calculated. Our study concluded that (a) maximum VMS was observed in the lid wiper in the absence of contact lens in the eye and (b) maximum VMS was observed in the superior 1.3 mm of the cornea in the presence of the contact lens in the eye. Thus, the development of friction-induced ocular surface disorders such as LWE, SLK, SEAL, and LSCD could be attributed to increased VMS. FEA is a useful simulation tool that helps us to understand the effect of blink on a normal eye with and without CL.